China Telecom Outdoor Wall Mounted Cabinet
China Telecom Outdoor Wall Mounted Cabinet

  1. China Telecom Outdoor Wall Mounted Cabinet
  2. China Telecom Outdoor Wall Mounted Cabinet
  3. China Telecom Outdoor Wall Mounted Cabinet
  4. China Telecom Outdoor Wall Mounted Cabinet
  5. China Telecom Outdoor Wall Mounted Cabinet

Telecom Outdoor Wall Mounted Cabinet

  1. MOQ: 1
  2. Price: Negotiation
  3. Get Latest Price
Payment Terms L/C, D/A, D/P, T/T, Western Union
Supply Ability 7,000 sets per month
Delivery Time 15-20 working days
Packaging Details wooden case
Application outdoor telecom base station
Material galvanized Steel
Color grey (support custom made)
Cabinet Lock anti-theft three point lock
Proof dustproof, sunproof and rainproof
Model ET655290P/01
External Size H×W×D 900×650×525mm
Brand Name ESTEL
Model Number ET655290P/01
Certification ISO9001, CE, 3C, FCC, TLC, IP55
Place of Origin Shenzhen, China (Mainland)

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, D/A, D/P, T/T, Western Union Supply Ability 7,000 sets per month
Delivery Time 15-20 working days Packaging Details wooden case
Application outdoor telecom base station Material galvanized Steel
Color grey (support custom made) Cabinet Lock anti-theft three point lock
Proof dustproof, sunproof and rainproof Model ET655290P/01
External Size H×W×D 900×650×525mm Brand Name ESTEL
Model Number ET655290P/01 Certification ISO9001, CE, 3C, FCC, TLC, IP55
Place of Origin Shenzhen, China (Mainland)
High Light outdoor wall mount cabinetwall mounted enclosure

 

Sunproof Rainproof Wall Mount Data Cabinet Outdoor Telecom Enclosure Grey Color​

 

Quick Details

 

Place of Origin: Shenzhen, China (Mainland) External Size H×W×D 900×650×525mm

Brand Name: ESTEL

Structure: sandwich structure, double wall, with insulation 

Model Number: ET655290P/01

Cabinet Layout: one compartment, for installing 19” equipment

Product Name: outdoor wall mounted cabinet

Cabinet Lock: anti-theft three point lock
Certification: ISO9001, CE, 3C, FCC, TLC, IP55

Protection Level: IP55

Application: outdoor telecom base station Cable Entry: at cabinet bottom
Material: galvanized steel Illumination: DC48V LED lamp

Heat Insulation: PEF

Grounding Protection: copper bar

Color: grey (support custom made)

Cooling: DC48V air conditioner

Coating: anti-corrosion outdoor powder coating

Accessories Options: PDU, environment monitoring system

 

Payment & Shipping Terms

 

Minimum Order Quantity: 1 set
Price: negotiation
Payment Terms: L/C, D/A, D/P, T/T, Western Union
Supply Ability: 7,000 sets per month
Delivery Time: 15-20 working days
Packaging Details: wooden case

 

1. Specifications

(1) Technical Parameters

 

Item Type Technical Parameter
Structure Dimension External Dimension H*W*D 900×650×525mm
Layout One compartment
Equipment Installation Method 19” standard rack
Door With one front door, and anti-theft three point lock for outdoor cabinet (support padlock)
Material

1.Galvanized steel;

2.Double wall, thickness of outer plate: 1.5mm, thickness of inner plate: 0.8mm, with heat insulation between two walls.

Structure Assembled
Ingress Protection IP55
Temperature Control Cooling 500W DC48V air conditioner
Lightning Proof Grade B lightning proof Nominal: 60KA, Max.: 100KA
Lighting LED lamp 48V LED lamp
Temperature Temperature Working Temperature: -20°C ~ 55°C
Storage Temperature: -40°C ~ + 70°C
Transport Temperature: -50°C ~ +70°C
Humidity Relative Humidity 5% ~ 100%
Pressure Air Pressure 62kpa ~ 101kpa (similar to 0m ~ 5000m altitude)
Radiation Intensity Solar Radiation Intensity 1124 × (1±5%)W/m2

 

Accessories List

 

No. Item Quantity Unit Specs
1 Outdoor Telecom Cabinet 1 Set

(1)External Dimension H×W×D 900×650×525mm

(2) One compartment;

(3) With one front door, and anti-theft three point lock for outdoor cabinet (support padlock) (4) Material: galvanized steel; double walls, thickness of outer plate: 1.5mm, thickness of inner plate: 0.8mm, with 40mm PEF heat insulation between two walls.

2 Air Conditioner 1 Set

Power Supply: DC48V

Cooling Capacity: 500W

Model: SAD105

3 Fans 2 PC DC48V
4 Power Distribution Unit 1 Set

Grade B Lightning Proof

AC Input: 63A/2P *1;

AC Output: 16A/1P*4;

DC Output: 16A/1P*4.

Height: 4U

5 Environment Monitoring Unit 1 Set 19” 1U SM2400
6 Door Sensor 2 Pc One for controlling led lamp, one for door open alarm
7 Smoke Sensor 1 Pc  
8 Water Sensor 1 Pc  
9 Temperature&Humidity Sensor 1 Pc  
10 LED lamp 1 Pc  
11 Package 1 Set Wooden Case

 

2. Application

 

The ET655290P/01 Wall Or Pole Mounted Outdoor Telecom Cabinet is widely used in wireless communication base station, such as 4G system, communication/network integrated service, access/transmission switching station, emergency communication/transmission, etc.

3. Features

 

3.1 The cabinet is dustproof, sunproof and rainproof, which is used in outdoor environment.

3.2 The cabinet use DC48V air conditioner and fans for cooling.

3.3 The cabinet includes -48VDC LED lamp for illumination.

3.4 The layout of the cabinet is reasonable, which will facilitate cable access, fixing and grounding. There’re cable entrance holes individually for power cable, signal cable and optical cable at the bottom of cabinet.

3.5 All the cables, seal and insulation material used in the cabinet are made from flame retardant materials.

3.6 The cabinet use standard 19” rack installation method.

 

4. Cabinet Introduction

4.1 Cabinet Structure: the cabinet use sandwich structure, outer plate is 1.5mm galvanized steel, inner plate is 0.8mm galvanized steel, with 40mm insulation between outer plate and inner plate.

 

4.2 Door and Door Lock: The cabinet includes one front door. The door opening angle is larger than 110° and the door limit device can limit the opening angle. The lock is theftproof three point lock, supports padlock.

 

4.3 Applicable environment conditions:

Environment temperature: -40°C ~ + 70°C;

Environment humidity (RH): ≤95% (at + 40°C);

Air pressure: 62kPa ~ 102kPa.

 

4.4 Material: galvanized steel.

 

4.5 Surface treatment: degreasing, derusting, rustproof phosphating (or galvanizing), powder coated.

 

4.6 Cabinet load bearing: ≥300kg.

 

4.7 Ingress protection: IP55.

 

4.8 Flame retardance: comply with GB5169.7 test A.

 

4.9 Insulation resistance: the insulation resistance between grounding devices and cabinet body parts is not lower than 2X104M/500V(DC).

 

4.10 Withstand voltage: the withstand voltage between grounding devices and cabinet body parts is not lower than 3000V(DC)/1min.

 

4.11 Mechanical strength: each surface can bear upright pressure>980N; after the door is open, its outer end can bear upright pressure >200N.

 

5. Dimension Diagram:

Cabinet External Size : 650×525×900mm (W×D×H).

 

 

6. Cabinet Layout

 

 

7. Sensors Installation

 

LED illumination lamp, door sensor, fans are installed at the top part of the cabinet.

 

8. Cable Entrance

 

All outside cables use bottom entrance method.

9. Grounding Protection

 

(1) The cabinet includes grounding copper bar with anti-corrosion coating. There are enough screws for wiring connection terminals.

(2) The metal part of the cabinet should be interconnected and be connected with grounding bar. Connection resistance between any two points is lower than 0.1Ω.

 

 

10. Theft Proof Design

10.1 Door lock theft proof design

 

(1) Damage resistance of the theft proof lock meets GA/T 73-1994 “Mechanical Anti-theft Lock”

class B requirement, supporting padlock.

 

 

 

(2) Three point lock

 

10.2 Connection and Fastening

 

  • Use anti-loose threaded connection as structure and bearer connection. Anchor bolt for fixing cabinet use hot dip galvanized bolts.
  • Door hinges use inner hinge mode.

 

 

 

10.3 Appearance and Surface Treatment

 

Cabinet surface coating is outdoor special powder coating, with white gray color (PANTONE 428C). The coating complies with GB/T 3181-2008 requirement.

 

11. Cabinet Installation

 

Install the cabinet as the following diagram.

 

 

12. Packing and Shipping

 

 

Our Delivery Agent

 

The goods can be shipped by sea, by air, by courier, by land, by train, etc.

Besides the following delivery agent, we can also look for the delivery agent with the best price in china if you need us to do for you.

 

 

13. Our Contact Information

 

Mobile Phone: 0086-13752765943

Telephone: 0086-0755 23592644

Email: info@estel.com.cn

           lxf.estel@hotmail.com
Skype: fiona.liang10

 

14. Our Partner

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler,Exporter

  • Year Established:

    2002

  • Total Annual:

    15 Million-20 Million

  • Employee Number:

    101~200

  • Ecer Certification:

    Verified Supplier

Introduction    Tianjin Estel Electronic Science and Technology Co., Ltd (ESTEL(GUANGDONG)TECHNOLOGY CO., LTD), located in China, is a professional supplier of integrated outdoor telecom cabinet and temperature control solutions for outdoor telecom base station. As a science and tech... Introduction    Tianjin Estel Electronic Science and Technology Co., Ltd (ESTEL(GUANGDONG)TECHNOLOGY CO., LTD), located in China, is a professional supplier of integrated outdoor telecom cabinet and temperature control solutions for outdoor telecom base station. As a science and tech...

+ Read More

Get in touch with us

  • Reach Us
  • Tianjin Estel Electronic Science and Technology Co.,Ltd
  • 3A-8, SHUIWAN 1979 SQUARE (PHASE II), NO. III, TAIZI ROAD, SHUIWAN COMMUNITY, ZHAOSHANG STREET, NANSHAN DISTRICT, SHENZHEN
  • https://www.outdoortelecomcabinet.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement