China factories

China factory - Tianjin Estel Electronic Science and Technology Co.,Ltd

Tianjin Estel Electronic Science and Technology Co.,Ltd

  • China,Shenzhen ,Guangdong
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China 9U Large Capacity Embedded Power Supply Standard 19-inch Rack Built-in Cabinet
China 9U Large Capacity Embedded Power Supply Standard 19-inch Rack Built-in Cabinet

  1. China 9U Large Capacity Embedded Power Supply Standard 19-inch Rack Built-in Cabinet
  2. China 9U Large Capacity Embedded Power Supply Standard 19-inch Rack Built-in Cabinet

9U Large Capacity Embedded Power Supply Standard 19-inch Rack Built-in Cabinet

  1. MOQ: 1 set
  2. Price: Negotiation
  3. Get Latest Price
Payment Terms L/C, D/A, D/P, MoneyGram, T/T
Supply Ability 3,000 sets per month
Delivery Time 15-20 working days
Packaging Details Wooden case
Name Rack Mount Telecom Rectifier
Rectifier Module 3KW×6pcs
Controller Ethernet , SNMP, ModBus and RS485 communication
Installation Mode 19 inch rack
Full Capacity 300A
Output Voltage -48VDC (-42 to -58VDC)
Module Hot-swappable
Battery Management Support
Output voltage DC48V
Application telecom,utility,Industrial Automation,Electric Power Transmission,BTS
Brand Name ESTEL
Model Number ETP48300
Certification ISO9001, CE, 3C, FCC, TLC
Place of Origin Shenzhen, China (Mainland)

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, D/A, D/P, MoneyGram, T/T Supply Ability 3,000 sets per month
Delivery Time 15-20 working days Packaging Details Wooden case
Name Rack Mount Telecom Rectifier Rectifier Module 3KW×6pcs
Controller Ethernet , SNMP, ModBus and RS485 communication Installation Mode 19 inch rack
Full Capacity 300A Output Voltage -48VDC (-42 to -58VDC)
Module Hot-swappable Battery Management Support
Output voltage DC48V Application telecom,utility,Industrial Automation,Electric Power Transmission,BTS
Brand Name ESTEL Model Number ETP48300
Certification ISO9001, CE, 3C, FCC, TLC Place of Origin Shenzhen, China (Mainland)
High Light 9U Embedded Power SupplyBuilt-in Cabinet Embedded Power SupplyLarge Capacity Embedded Power Supply

 

9U Large Capacity Embedded Power Supply Standard 19-inch Rack or Built-in Cabinet

 

1. 9U Large Capacity Embedded Power Supply Features

 

 

DC Rectifier System supply 9U height compact design to meet critic

alapplication needs of fiber and microwave transmission, access device,

switch. The system maximum power is 300A, with customized AC/battery/load MCBs.

The cables are front accessing with MCB and busbar

 

  • Standard 19-inch width which has the advantage of wide use
  • 5U height compact design, space and installation cost can be saved
  • Front operation and cable accessing, good-looking and safe maintenance
  • Perfect battery management, prolongs the life of the battery well provide,various communication ports, RS485, internet port, dry contacts, etc.which enables flexible networking and remote monitoring
  • Rectifier and controller are hot pluggable, easy and quick on-line maintenance
  • Wide input voltage range(85-300Vac) the power grid is adaptable

 

2. 9U Telecom Power Supply Parameter

 

Model ETP48300
System Dimension(mm) 482.6(W)x350.6(D)x9U(H)
  Weight ≤ 50kg(without rectifier module)
  Cooling mode Forced air cooling
  Installation mode Installed on 19-inch rack or inside the cabinet
  IP Grade IP20
AC Distribution Input voltage

380VAC, three phase

  Input capacity 2x63A/4P
  Input frequency 45~65Hz, rated 50/60Hz
  AC SPD 20kA/30kA, 8/20μs

DC Distribution

Output voltage -42~-58VDC, rated value: -53.5VDC
  Maximum capacity 18kW(6x3000W rectifier module)
  Battery breakers

2x125A/1P

  Load breakers

User 1:

LLVD1: 1×125A/1P, 1×63A/1P, 1×16A/1P, 1×6A/1P;

BLVD1: 1×63A/1P;

User 2:

LLVD2: 1×63A/1P, 2×16A/1P, 1×6A/1P;

BLVD2: 1×63A/1P;

User 3:

LLVD3: 1×63A/1P, 2×16A/1P, 1×6A/1P;

BLVD3: 1×63A/1P;

User 4:

LLVD4: 1×63A/1P;

BLVD4: 3×10A/1P;

  DC SPD 10kA/20kA, 8/20μs(designed inside)
Rectifier Module Input voltage 85VAC-300VAC, rated value: 220VAC
  Efficiency ≥96%
  Rated power 3000W(176~300VAC )
  Dimension 106.5mm(W)×286mm(D)×41.5mm(1U/H)
  Cooling mode Forced cooling with fan
Controller Signal input 3 AI(2 battery temp., 1 ambient temp) ,7 DI(SPD, 6 common DI)
  Alarm output 6 dry contact
  Communication port RS485/LAN Ethernet/SNMP
  Display mode LCD

Environment

Operating temperature

-40℃~+65℃
  Storage temperature -40℃~+70℃
  Operating humidity 5%~95%(non-condensing)
  Altitude 0~3000m(If the altitude is within the range of 2000m to 3000m, the maximum operating temperature decreases by 1℃ as the altitude increases by 200m.)

 

 

3. ESTEL 48v Telecom Power Supply

 

A rectifier converts alternating current (AC) to direct current (DC) and provides the power necessary to charge batteries. With a focus on continuously improving the total cost of ownership, ESTEL’s rectifiers, combined with advanced control and monitoring features, help reduce both capital and operational expenditure. Our rectifiers boast excellent power density while fulfilling space and weight requirements. They leave plenty of room for other equipment and create savings in packaging and transportation costs. In addition, their high efficiency lowers total energy consumption and reduces carbon footprint.

ESTEL’s rectifiers are easy to install, as their connectors are located at the rear and are hot-pluggable. Fan cooling with speed control renders operating almost silent. In general the rectifiers include a wide AC input voltage range, protection against AC overvoltage and optional protection against loss of neutral, which make this solution very reliable even in the regions with AC utility network problems.

 

 

4. Product Pictures 

 

 

 

 

Rack mounted pictures for reference:

19" 5u Subrack 220V AC To 48V DC Rectifier System Switch Mode Power Supply For Telecom  2

 

 

5. Controller-MC2600 (Monitoring Module)

 

The MC2600 front panel

 

 

                (1) LAN port     (2) RS485 port    (3) Run indicator       (4) Minor alarm indicator

                (5) Major alarm indicator             (6) Handle                 (7) Buttons

 

 

Table for controller button description

 

Button Description
ESC

Returns to the previous menu without saving the settings.

Press the ESC and ENT button at the

same time within a short period of

time can restart the controller.

ENT.

 

Ø Enters the main menu from the standby

screen.

Ø Enters a submenu from the main menu.

Ø Saves the menu settings.

UP

Turns to the previous menu or sets parameter values.

When setting parameter values, you can hold down this button to quickly adjust values.

When the parameter value is set by

multiple string types, press up or

down button to change each value.

After setting the value, press the

confirm button to move the cursor

back automatically.

DN.

Turns to the next menu or sets parameter values.When setting parameter values, you can hold down this button to quickly adjust values.

 

Describes the indicator on the controller panel is shown in table below

 

Type Color State Instructions
Run indicator Green Flickering Controller is running properly
Off Controller is fault or has no DC input
Minor Alarm Yellow Normally on The controller generates a minor alarm
Off The controller does not generate any minor alarms
Major alarm Red Normally on The controller generates a major alarm
Off The controller does not generate any major alarms


 

The controller provides two communication ports

 

The definition of RS485 communication port is shown in below table

 

Pin No. 1 2 3 4 5 6 7 8
Signal name RS485+ - RS485- - - - - -

 

 

 

 

The LAN Ethernet port interface definition is shown in Table

 

Pin No. 1 2 3 4 5 6 7 8
Signal name TX+ TX- RX+ - - RX- - -

 

 

 

 

 

6. Subrack Installation

 

Install the subrack to the 19-inch rack, as shown in Figure below.

 

Ø Step 1,Remove the plug from the package.

Ø Step 2,Push the plug into the 19-inch rack

Ø Step 3,Install the fixed screw (if the mounting hole of the plug frame ear does not correspond to the position of the floating nut of the frame,

it needs to be adjusted according to the actual installation).

 

 

 

Install Rectifier/Solar module

 

Ø Step 1, Take out the module from the package.

Ø Step 2, Hold the module handle on the front panel and put the module onto the slot.

Ø Step 3, Push the module slowly to the front panel of the module and flush with the power

distribution panel.

Ø Step 4, Tighten the fixing screw on the module panel so that the module does not come off.

 

 

 

 

 

 

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler,Exporter

  • Year Established:

    2002

  • Total Annual:

    15 Million-20 Million

  • Employee Number:

    101~200

  • Ecer Certification:

    Verified Supplier

Introduction    Tianjin Estel Electronic Science and Technology Co., Ltd (ESTEL(GUANGDONG)TECHNOLOGY CO., LTD), located in China, is a professional supplier of integrated outdoor telecom cabinet and temperature control solutions for outdoor telecom base station. As a science and tech... Introduction    Tianjin Estel Electronic Science and Technology Co., Ltd (ESTEL(GUANGDONG)TECHNOLOGY CO., LTD), located in China, is a professional supplier of integrated outdoor telecom cabinet and temperature control solutions for outdoor telecom base station. As a science and tech...

+ Read More

Get in touch with us

  • Reach Us
  • Tianjin Estel Electronic Science and Technology Co.,Ltd
  • 3A-8, SHUIWAN 1979 SQUARE (PHASE II), NO. III, TAIZI ROAD, SHUIWAN COMMUNITY, ZHAOSHANG STREET, NANSHAN DISTRICT, SHENZHEN
  • https://www.outdoortelecomcabinet.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement