China High Stability Environment Monitoring System 4 Wire DC 32~52V Relay Output Alarm
China High Stability Environment Monitoring System 4 Wire DC 32~52V Relay Output Alarm

  1. China High Stability Environment Monitoring System 4 Wire DC 32~52V Relay Output Alarm

High Stability Environment Monitoring System 4 Wire DC 32~52V Relay Output Alarm

  1. MOQ: 1 set
  2. Price: Negotiation
  3. Get Latest Price
Payment Terms T/T, L/C,D/A, Western Union, Paypal, etc
Supply Ability 8,000 sets per month
Delivery Time 10 working days
Packaging Details Carton/wooden case
Working voltage DC32~52V
Working temperature -10℃~+50℃
Alarm output Relay output
Alarm indication Red LED always on
Usage Industrial
Dimension 103mm diamcter * 53mm deep
Brand Name ESTEL
Model Number S03 -A4
Certification ISO9001, CE, 3C, FCC, TLC,
Place of Origin Shenzhen, China (Mainland)

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, L/C,D/A, Western Union, Paypal, etc Supply Ability 8,000 sets per month
Delivery Time 10 working days Packaging Details Carton/wooden case
Working voltage DC32~52V Working temperature -10℃~+50℃
Alarm output Relay output Alarm indication Red LED always on
Usage Industrial Dimension 103mm diamcter * 53mm deep
Brand Name ESTEL Model Number S03 -A4
Certification ISO9001, CE, 3C, FCC, TLC, Place of Origin Shenzhen, China (Mainland)
High Light environmental monitoring systemsenvironmental monitoring unit4 Wire Environment Monitoring System

 
4 Wire DC32~52V Security Monitoring System Photoeleciric Smoke Detector  
 
1. Prodcut Instruction
 

This product named Photoeleciric smoke detector(hereinafter called detector) delecis the smoke by a couple of infrared diodes. The principle of detecting is granule in the smoke can reflect infrared light. Infrared diodes are placed in the special chamber. The chamber can shield external light, but doesn,t affect the smoke into it. While there is no smoke, the diode can receive very weak infrared light. When the smoke entering the chamber, diode can receive more and more light, and the detector can give out alarm signal when the smoke allains the certain density. In order to reduce the interference and lower power consumption, the emitting circuit adopts the pulse signal. The product in accordance with the networking approach is 4-wire detectors.

 
2. Product Specification
 

Working voltage DC32~52
Standby current

 2mA (48V NO) ;
 13mA (48V NC)

Alarm current

 16mA (48V NO)
  6mA (48V NC)

Alarm indication  Red LED on
Humidity  0%-95% RH(no condensation)
Working temperature  -10℃~+50℃
Contact rating 100mA@DC28V
Alarm output

 Relay output

Sensitivity 0.5db/m (±0.1db/m)
External dimension 103mm diamcter*53mm dee

 
3. Connection Description
 

4 wire smoke detectors :

 

“1” and “2” for DC power input, non-polarized .

”3” for relay output com.

“4” for relay output N.C. or N.O.
 
4. Prodcut Features
 

  • Strong adaptability for circumstance
  • SMT design,High stability
  • 32-52VDC wide voltage operating rance 
  • Low standby current
  • Power supply non-polarizedinput
  • Twin LED for 360 degree visual
  • Flashing LED power indicator
  • Anti-electromagnetic interference.

 
5. Product Diagram

 

 
 

6. Notice

 

1. The detector can not be installed under worse environment. E.g. coldest, hottest, dusty, do not move away the dustproof cover untill use the detector indeed.

2. Make sure that there is no block within 0.5m from detector.

3. Keep the distance between detector and wall more than 05 . m.

4. Make sure the distance between detectors be less than 15m. And the distance between detector and corner must be less than half of the one between detectors.

5. Horizontally install the detector. If have to be installed slantingly, please keep the angle less than 45 degrees)

6. Deteclors base be installed solid, wire connections must be reliable.

7. Recommendations should be carried out every six months a simulated fire test, the test detectors are working properly.

8. For various reason, including, but not limited to changes in environmental conditions, electric disruptions and tampering, the product may not perform as expected, The user is advised to take all necessary precautions for his/her safety and the protection of his/her property.
 
 
 


















Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler,Exporter

  • Year Established:

    2002

  • Total Annual:

    15 Million-20 Million

  • Employee Number:

    101~200

  • Ecer Certification:

    Verified Supplier

Introduction    Tianjin Estel Electronic Science and Technology Co., Ltd (ESTEL(GUANGDONG)TECHNOLOGY CO., LTD), located in China, is a professional supplier of integrated outdoor telecom cabinet and temperature control solutions for outdoor telecom base station. As a science and tech... Introduction    Tianjin Estel Electronic Science and Technology Co., Ltd (ESTEL(GUANGDONG)TECHNOLOGY CO., LTD), located in China, is a professional supplier of integrated outdoor telecom cabinet and temperature control solutions for outdoor telecom base station. As a science and tech...

+ Read More

Get in touch with us

  • Reach Us
  • Tianjin Estel Electronic Science and Technology Co.,Ltd
  • 3A-8, SHUIWAN 1979 SQUARE (PHASE II), NO. III, TAIZI ROAD, SHUIWAN COMMUNITY, ZHAOSHANG STREET, NANSHAN DISTRICT, SHENZHEN
  • https://www.outdoortelecomcabinet.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement