China factories

China factory - China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

  • China,Guangzhou ,Guangdong
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China C613 SonoScape Micro Convex Transducer 4.0-13.0 MHz For E5 Exp E5 Pro E3 Exp E3
China C613 SonoScape Micro Convex Transducer 4.0-13.0 MHz For E5 Exp E5 Pro E3 Exp E3

  1. China C613 SonoScape Micro Convex Transducer 4.0-13.0 MHz For E5 Exp E5 Pro E3 Exp E3
  2. China C613 SonoScape Micro Convex Transducer 4.0-13.0 MHz For E5 Exp E5 Pro E3 Exp E3
  3. China C613 SonoScape Micro Convex Transducer 4.0-13.0 MHz For E5 Exp E5 Pro E3 Exp E3
  4. China C613 SonoScape Micro Convex Transducer 4.0-13.0 MHz For E5 Exp E5 Pro E3 Exp E3

C613 SonoScape Micro Convex Transducer 4.0-13.0 MHz For E5 Exp E5 Pro E3 Exp E3

  1. MOQ: 1pcs
  2. Price:
  3. Get Latest Price
Payment Terms T/T(wire transfer), Western Union, Paypal
Delivery Time 3-5 working days
Packaging Details Carton
Product Name C613 SonoScape Micro-Convex Transducer Transducer 4.0-13.0 MHz For E5 Exp/E5/E5 Pro/E3 Exp/E3/ E3 Pro/E2 Exp/ E1 Exp/E1
Brand SonoScape
Part No . C613
Application Abdomen, Cardiac, Urology, Pediatrics
Center frequency 6.5MHz
Field of View 90°
Bandwidth 4.0-13.0 MHz
Radius 14 mm
Compatible Ultrasound Machine 1.E5 Exp/E5/E5 Pro/E3 Exp/E3/ E3 Pro/E2 Exp/E2/E2 Pro/ E1 Exp/E1/E1 Pro
Brand Name SonoScape
Model Number C613

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T(wire transfer), Western Union, Paypal Delivery Time 3-5 working days
Packaging Details Carton Product Name C613 SonoScape Micro-Convex Transducer Transducer 4.0-13.0 MHz For E5 Exp/E5/E5 Pro/E3 Exp/E3/ E3 Pro/E2 Exp/ E1 Exp/E1
Brand SonoScape Part No . C613
Application Abdomen, Cardiac, Urology, Pediatrics Center frequency 6.5MHz
Field of View 90° Bandwidth 4.0-13.0 MHz
Radius 14 mm Compatible Ultrasound Machine 1.E5 Exp/E5/E5 Pro/E3 Exp/E3/ E3 Pro/E2 Exp/E2/E2 Pro/ E1 Exp/E1/E1 Pro
Brand Name SonoScape Model Number C613
High Light C613 Micro Convex Transducer13.0 MHz Micro Convex TransducerExp E1 Micro Convex Transducer

C613 SonoScape Micro-Convex Transducer Transducer 4.0-13.0 MHz For E5 Exp/E5/E5 Pro/E3 Exp/E3/ E3 Pro/E2 Exp/ E1 Exp/E1//E1 Pro

 

 

 

The SonoScape E-Series supports a wide variety of probes, making the system extremely flexible. The schematic diagram of the probe is as follows

 

Body Surface Probe

 

Endocavitary Probe

 

The available probes are listed as follows

Probe Model Application

L741, 3C-A, 3P-A,7P-B, 12L-B, C613, PWD2.0, 12LI-A,

10I2, 6CT-A

 

Body surface
6V1, 6V3, EC9-5 Intracavitary

 

Features for C613 probe

 

Application Abdomen, Cardiac, Urology, Pediatrics
Center frequency 6.5MHz
Field of View 90°
Bandwidth 4.0-13.0 MHz
Radius 14 mm

 

 

Cautions

 

  • Use only the probes provided by the manufacturer. Otherwise, the system may not work and accidents such as fire may occur.

 

  • Use the probe carefully. If any part of the probe surface is scratched, stop using it immediately. Failure to do so may result in electric shock.

 

  • Endovascular procedures require a legally sold tube sheath. If a lubricant is used, it must be water-soluble. Do not apply the coupling gel directly to the patient's skin. Dispose of the housing in accordance with local laws and regulations.

 

  • For intraoperative transvaginal, transrectal, or transesoPHiliphhilipageal (cardiac) examinations, use a sterile probe cover and coupling gel. In the absence of lubrication due to age or personnel during the examination, a sufficient amount of sterile coupling gel should be applied to the surface of the socket.

 

 

  • To avoid contamination, a coupling gel and probe cover should be used before continuing the test.

 

 

  • Use legally sold coupling gels in accordance with local regulations. Read and understand all the precautions in the coupling gel instruction manual before use. Latex or natural rubber in medical devices or accessories can cause severe allergic reactions in some people. The FDA advises operators to identify latex-sensitive patients and prepare to promptly treat allergic reactions.

 

  • When the probe and its accessories become contaminated with hard-to-kill pathogenic bacteria such as cryptosporidia or prions, they must be destroyed by melting or, if necessary, burning, as they cannot be fully disinfected and sterilized.

 

  • Prolonged immersion of the transducer surface in the coupling gel should be avoided as this may damage the probe.

 

  • When cleaning, disinfecting, or sterilizing the probe and probe cable, be careful not to spill liquid on the probe or probe connector.

 

Be especially careful before using the probe

Check the probe before each use. Stop using the probe immediately if you find the following damage.

  • Cracks in the probe handle (user side).
  • Cracks on the surface of the transmitter (applied part).
  • The surface of the transducer (surface of the acoustic window) has scratches.
  • The material of the acoustic window expands.
  • The probe cable is broken or frayed.
  • Cracks or other visible damage to the probe connector.
  • The pins in the probe connector are deformed or broken.
  • The probe cable is damaged or deformed.

 

 

Application of the probe to the body surface

 

1. Put on sterile medical gloves.

2. Connect the probe.

 

3. Run a scan.

 

■ Endocavitary Probe Usages

 

1. Put on sterile medical gloves.

2. Cover the probe with the probe cover (only for Intralight probes).

A. Remove the packaging and open the probe cover.

B. Apply an appropriate amount of coupling gel inside the sheath and on the surface of the probe

 

 

 

C. Hold the tube and flip the cap over the tube.

D. Pull the probe cover tightly over the probe surface to remove wrinkles.

E.Secure the cover to the pipe with tape or a rubber band

 

3. Position the probe Before scanning, check the orientation markings on the probe.

4. Run a scan.

 

 

 

Cleaning the Probe

The probe should be cleaned before and after each use. Cleaner research is an important step in disinfection and sterilization. Follow the steps below to clean your study.

 

1.After inspection, remove the coupling gel from the probe surface.

2. Disconnect the examiner from the system and remove the test cap and tissue sample holder from the examiner.

3. Clean the meter with a soft, lint-free cloth dampened with mild soapy water or the recommended detergent (see Appendix D.2 Detergent). If there are dry spots on the surface of the probe or in the cracks, use a brush to remove them. Moisten them with enzyme detergent.

Rinse the examiner's surface with clean tap water to completely remove any detergent residue.

5. Wipe the meter with a soft, dry, lint-free cloth.

 

 

If you have any interest in C613 SonoScape Micro-Convex Transducer Transducer 4.0-13.0 MHz For E5 Exp/E5/E5 Pro/E3 Exp/E3/ E3 Pro/E2 Exp/ E1 Exp/E1//E1 Pro ,feel free to contact us .

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler,Agent,Importer,Exporter,Trading Company,Seller

  • Year Established:

    2015

  • Employee Number:

    20~50

  • Ecer Certification:

    Verified Supplier

China World Technology Medical Equipment Service Group is a company engaged in medical equipments/repair parts and accessories products trading company. The company was established in September 2005, has many famous enterprises at home and abroad (such as America USCO company) to establish a long-te... China World Technology Medical Equipment Service Group is a company engaged in medical equipments/repair parts and accessories products trading company. The company was established in September 2005, has many famous enterprises at home and abroad (such as America USCO company) to establish a long-te...

+ Read More

Get in touch with us

  • Reach Us
  • China World Technology Medical Equipment Service Group
  • TianHe District,GuangZhou,GuangDong
  • https://www.patients-monitor.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement