Payment Terms | T/T, PayPal, Western Union |
Supply Ability | 200000 pcs per month |
Delivery Time | Negotiation |
Packaging Details | Inner Box, Carton, Pallet |
Acting Type | Direct Acting Normally Closed |
Name | 2V025-08 Airtac Type Fluid Control Pneumatic Solenoid Valve |
Coil Voltage | DC 24V |
Electrical Entry | Terminal |
Orifice Size | 2.5mm |
Port Size | 1/4'' inch |
Connection | Thread |
Valve Type | Single Solenoid 2 Port (2 Way) 2 Position |
Body Material | Aluminum, Anodised |
Seals Material | NBR (Buna N) |
Brand Name | Brando |
Model Number | 2V025-08 |
Certification | CE |
Place of Origin | China |
View Detail Information
Explore similar products
1/2'' Double Coils 5/2 Way Pneumatic Cylinder Valve 4V420-15 0.15-0.8MPa
Silver Color Lead Wire or Connector type 5/3 Way Pneumatic Air Control Valve
5/2 Way 1/8'' NPT 4V120-06 Internal Pilot Aluminum Alloy Double Solenoid
Cng Injector Rails Solenoid Valve Parts Valve Stems 22g Two Way Type
Product Specification
Payment Terms | T/T, PayPal, Western Union | Supply Ability | 200000 pcs per month |
Delivery Time | Negotiation | Packaging Details | Inner Box, Carton, Pallet |
Acting Type | Direct Acting Normally Closed | Name | 2V025-08 Airtac Type Fluid Control Pneumatic Solenoid Valve |
Coil Voltage | DC 24V | Electrical Entry | Terminal |
Orifice Size | 2.5mm | Port Size | 1/4'' inch |
Connection | Thread | Valve Type | Single Solenoid 2 Port (2 Way) 2 Position |
Body Material | Aluminum, Anodised | Seals Material | NBR (Buna N) |
Brand Name | Brando | Model Number | 2V025-08 |
Certification | CE | Place of Origin | China |
High Light | solenoid operated valve ,solenoid pneumatic valve |
1/4'' 2V025-08 Airtac Type Fluid Control Pneumatic Solenoid Valve 2/2 Way Direct Acting NC
The Airtac 2V025 series pneumatic solenoid valve is a functional replacement for the SMC VXP series.
Feature of 2V025 Series Aluminum Solenoid Pneumatic Air Valve 2 Way, Direct Acting, Normally Closed:
1. Direct-acting normally closed 2/2-way solenoid valve. High sensitivity makes it possible to change direction quickly.
2. The structure is compact and small.
3. The valve body is made of heat-resistant brass and the coil meets Class B standards. The seals are made of fluoro rubber (VITON) and are suitable for many types of working media.
Main dimension of 2V025-08 Airtac Type Fluid Control Pneumatic Solenoid Valve:
Technical parameters of Airtac Type 2/2 Way NC Fluid Control Solenoid Valve:
Model | 2V025-06 | 2V025-08 | 2V130-10 | 2V130-15 | 2V250-20 | 2V250-25 |
Fluid | Air. Water. Oil | |||||
Acting | Direct acting | Internally piloted acting | ||||
Type | Normally closed | |||||
Orifice size(φmm) | 2.5 | 2.5 | 13.0 | 13.0 | 25.0 | 25.0 |
Cv valve | 0.23 | 0.25 | 6.20 | 6.20 | 13.00 | 13.00 |
Port size | 1/8" | 1/4" | 3/8" | 1/2" | 3/4" | 1" |
Viscosity limit | Under 20CST | |||||
Pressure range | 0~1.0MPa (0~145psi) | 0.05-1.0MPa (7~145psi) | ||||
Proof pressure | 1.5MPa(215psi) | |||||
Material body | Aluminum, Anodized | Brass | ||||
Seal material | NBR | NBR | ||||
Min. activating time sec | 0.05 sec and below |
Disassembly show of Direct Acting Normally Closed 2V025-08 Air Solenoid Valve:
Details enlargement of 1/4'' AIRTAC Type Aluminum Pneumatic Solenoid Air Valve:
More display of 2V025-08 AIRTAC Type 2 Position 2 Way Pneumatic Air Valve:
Packing display of 2V025-08 Airtac Type Fluid Control Solenoid Pneumatic Valve:
Installation of 2V025-08 Airtac Type Fluid Control Pneumatic Solenoid Valve:
To Connect the Valve Inlet & Outlet:
Connect the inlet & outlet to the valve ports according to the flow direction arrow marked on the valve.
To Install the Coil:
Put the coils on to the armature tube of the valve. Place the lock washer & nut on to the armature tube. Hand tighten the nut, then use a wrench to tighten the nut another quarter-turn. Do not over-tighten the nut, as it may cause the armature tube to fail prematurely.
To Connect a DIN Coil:
1. Remove the screw from the plastic DIN housing & unplug it from the DIN coil
2. From the screw opening, push the terminal block out from the plastic DIN housing.
3. Note the “1”, “2”, and ground “⏚” symbols on the underside of the DIN enclosure.
4. For DC DIN Coils, connect “1” to your Positive Lead & “2” to your Negative lead.
5. For AC DIN Coils, connect “1” to your HOT lead, “2” to your Neutral lead, & “⏚” to your ground if required.
Do not energize the coil without installing it onto the valve or connect the coil to a different voltage than specified. This will burn the coil and could create fire hazards.
Welocome to your any question and inquiry!
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Exporter,Seller
Year Established:
2008
Total Annual:
8million-9million
Employee Number:
50~100
Ecer Certification:
Verified Supplier
* Foucus on your demand, Offer you best solutions as the first mission of Ningbo Brando Hardware Co., Ltd, we work on designing and manufacturing solenoid coils, solenoid armatures and solenoid valves for more than 15 years. * We have served customers fr... * Foucus on your demand, Offer you best solutions as the first mission of Ningbo Brando Hardware Co., Ltd, we work on designing and manufacturing solenoid coils, solenoid armatures and solenoid valves for more than 15 years. * We have served customers fr...
Get in touch with us
Leave a Message, we will call you back quickly!