China Energy Efficient Operation Modular Data Center Space Saving
China Energy Efficient Operation Modular Data Center Space Saving

  1. China Energy Efficient Operation Modular Data Center Space Saving
  2. China Energy Efficient Operation Modular Data Center Space Saving
  3. China Energy Efficient Operation Modular Data Center Space Saving

Energy Efficient Operation Modular Data Center Space Saving

  1. MOQ: 1set
  2. Price: USD1800-30000/set
  3. Get Latest Price
Payment Terms T/T, L/C
Supply Ability 300 PCS PER MONTG
Delivery Time 20-40 days
Packaging Details Packed in plywooden case, standard export package
After-sales service provided Engineers available to service machinery overseas
Operating voltage 380/400 VAC,230 VAC,220V
Fan type Axial Fan,Direct driven or belt driven,direct driven/belt driven/AC/EC plug fan,AC direct drive fan
Power 3N-380V-50Hz,220v/50hz/60hz
Airflow 2000~50000 m3/h
Voltage 380v/220v,220V/380V,380V/415V
Brand Name COOLNET
Model Number CYA,M08,CR012
Certification CE,ISO
Place of Origin CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, L/C Supply Ability 300 PCS PER MONTG
Delivery Time 20-40 days Packaging Details Packed in plywooden case, standard export package
After-sales service provided Engineers available to service machinery overseas Operating voltage 380/400 VAC,230 VAC,220V
Fan type Axial Fan,Direct driven or belt driven,direct driven/belt driven/AC/EC plug fan,AC direct drive fan Power 3N-380V-50Hz,220v/50hz/60hz
Airflow 2000~50000 m3/h Voltage 380v/220v,220V/380V,380V/415V
Brand Name COOLNET Model Number CYA,M08,CR012
Certification CE,ISO Place of Origin CHINA
High Light Standardized Modular Data CenterIP20 Modular Data Center

Green And Energy Efficient Operation With Modular Data Center Space Saving

 

 

Product Introduction                                                                           

 Coolnet modular standardized data centers are designed with a standardized, modular architecture, meaning that infrastructure investments do not need to be made in one step when building the physical infrastructure of the data center, saving initial investment costs. Avoiding one-time investment in infrastructure such as cooling, power supply and racks takes up a lot of money and can result in idle resources. Instead, the data center of the required scale can be deployed only according to the current business needs, and then expanded as the business needs develop, and cooling, power supply, racks and other equipment can be invested in phases, greatly reducing the initial construction costs.

 

 

 

Benefits                                                                                                                                             

 

 

Features                                                                                                                     

                                                           

1. Customized hardware facilities to improve cost performance.

Modularized network architecture, customized servers, micro-modules and their infrastructure according to specific business deployment.

 

2,Factory prefabrication, on-site assembly, and rapid deployment.

Standardization and productization of components, high quality control and clear engineering interface.

 

3,Change the cooling method.

In row cooling to meet the requirements of medium and high power density server rooms (5-12kW/rack).

Proximity cooling, channel closure. Energy transfer in close proximity, cold and heat isolation, total energy consumption of the server room is reduced by 10%.

Can be based on IT cabinet requirements, server room area and power density and other factors, the flexibility of a variety of unit components organically assembled together to achieve a standard, balanced micro-module composition design, and can be customized according to the specific project situation, very flexible.

 

4,Cold pool and inter-row cooling

Composed of two columns of equipment units facing each other, plus the channel closure components, skylights, side doors, etc. itself to achieve cold and hot channel isolation.

The inter-column air supply distance is short, the refrigeration system control strategy is highly accurate, and it can also achieve flexible cooling on demand, while this approach supports high-density loads.

 

5,Comes with uninterruptible power supply system

Internal integrated UPS or 240V DC and battery uninterruptible power supply system. Different micro-modules can be powered by different power supply systems to achieve a variety of power supply forms mixed in the same room.

 

6,Easy disassembly and assembly

Prefabricated by the factory, with industrial and standardized features, can be easily disassembled and assembled. The construction time is short and the construction site is easy to manage.

 

 

Air Supply Method                                                                                                                                                       

Technical Specification                                                                                          

                                            

Equipment System Item Parameter
System Dimension 1200mm enclosed cold/hot aisle dual-row cabinets
    1200mm enclosed cold/hot aisle Single-row cabinets
  Rack Quantity Dual Row Racks:≤48,Single Row Racks:≤24
Rack Dimensions 600mm(W)*1200mm(D)*2000mm(H), can be customerized,42U
  Protection Class IP20
Enclosed Aisle Skylight 300mm / 600mm wide turning skylight,Flat roof skylight,Fixed skylight
Power Supply and Distribution Dimension 600mm(W)*1200mm(D)*2000mm(H)
  UPS Power Supply 380VAC/400VAC/415VAC(3Phase 5Wire),50/60Hz,PF=0.99
  Battery 40AH~240AH/12V Valve Regulated Lead Acid Battery
Cooling Indoor Unit Size 300mm(W)*1200mm(D)*2000mm(H),600mm(W)*1200mm(D)*2000mm(H)
  Cooling Capacity Cooling:20~40KW,Chilled water :20~70KW,Chilled water :20~70KW
  Power Supply 3Phase 380VAC,50Hz
  Air Supply Front Supply
  Type Enclosed Hot/Cold Aisle
  Protection IP20
Monitoring System Monitoring Temperature and humidity, smoke detection, smart access control, camera, water leakage alarm
  Equipment monitoring Power supply, battery, power distribution, air conditioning

 

                                        

Factory Details                                                                                                        
                                               

 

                                  

Cases                                                                                                                         

                                                          

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2010

  • Total Annual:

    10,000,000.00-10,000,000.00

  • Employee Number:

    100~150

  • Ecer Certification:

    Verified Supplier

Coolnet focuses on the R&D, production and application of data center integrated solutions. It is a service provider in the field of information infrastructure construction, with technology, products and solutions, and is committed to providing customers with products and overall solutions in th... Coolnet focuses on the R&D, production and application of data center integrated solutions. It is a service provider in the field of information infrastructure construction, with technology, products and solutions, and is committed to providing customers with products and overall solutions in th...

+ Read More

Get in touch with us

  • Reach Us
  • Hefei Coolnet power Co., ltd
  • Room 303, 3rd Floor, Building C, Yingte Workshop, West Section of Yanglin Road, High-tech Zone Mechanical and Electrical Industrial Park, Hefei City Anhui Province
  • https://www.precisionacunits.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!