China 50KW In Row Air Conditioning Unit Floor Standing For Data Center
China 50KW In Row Air Conditioning Unit Floor Standing For Data Center

  1. China 50KW In Row Air Conditioning Unit Floor Standing For Data Center
  2. China 50KW In Row Air Conditioning Unit Floor Standing For Data Center
  3. China 50KW In Row Air Conditioning Unit Floor Standing For Data Center

50KW In Row Air Conditioning Unit Floor Standing For Data Center

  1. MOQ: 1Unit
  2. Price: USD3000-20000/Unit
  3. Get Latest Price
Payment Terms T/T, L/C
Supply Ability 1000Unit/Month
Delivery Time 20-35Days
Packaging Details Packed in plywooden case, standard export package
cooling capacity 50KW
Condition New
After-sales service provided Engineers available to service machinery overseas
Operating voltage 380/400 VAC,230 VAC,220V
Refrigerant R22(R407C/R410A)
Power 3N-380V-50Hz,220v/50hz/60hz
Brand Name Coolent
Model Number CYAS40D/U
Certification ISO/CE
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, L/C Supply Ability 1000Unit/Month
Delivery Time 20-35Days Packaging Details Packed in plywooden case, standard export package
cooling capacity 50KW Condition New
After-sales service provided Engineers available to service machinery overseas Operating voltage 380/400 VAC,230 VAC,220V
Refrigerant R22(R407C/R410A) Power 3N-380V-50Hz,220v/50hz/60hz
Brand Name Coolent Model Number CYAS40D/U
Certification ISO/CE Place of Origin China
High Light Inrow Cooling Unit Floor StandingIn Row Air Conditioning Unit 50KWIn Row Air Conditioning Unit R22

Floor Standing Cool Row Air Conditioning Unit 50KW For Data Center

 

 

Product Introduction                       

The In-row air conditioner is a device placed between the columns of the server cabinet, and the heat source directly dissipates heat. The precision air conditioner in the inter-row room is a type of air conditioner in the room. It is a horizontal air supply unit. Due to the increasing heat dissipation of the server or communication equipment used in the data center, the traditional air conditioning refrigeration method can no longer meet the requirements of the equipment for temperature and humidity. In order to achieve efficient cooling of the equipment and avoid local overheating phenomenon, cold air must be organized into the interior of the equipment for heat dissipation. At this time, the cold and hot channel isolation or closure of the cold and hot channel can effectively control the short circuit of the cold air flow and hot air flow, and reduce the cooling effect.

 

Advantage                                          

 

  • Near-end cooling: close to the heat source for cooling. Cooperate with the design of hot and cold channels to further optimize the indoor air distribution, reduce the overall PUE value of the equipment room, and improve the cooling efficiency.

 

  • High energy efficiency ratio: high return air temperature and high heat output air temperature matching degree is high, making the unit energy efficiency ratio is very good, low consumption, energy saving, low operating cost.

 

  • High reliability: super long life design, 24 hours and 365 days uninterrupted operation, the average design life is about 10 years.

 

  • Using DC frequency conversion compressor, dynamic refrigeration, high efficiency, low consumption, high adaptability; An EC centrifugal fan with N+1 redundancy is configured to automatically adjust the air supply volume according to the equipment room load.

 

  • The standard rack size is the same as the cabinet appearance. It is beautiful and easy to expand capacity.

Application                            

 

 

In row air condition are specially designed for modern modular data centers, such as high-thermal density data centers, various modular data centers, data centers with low PUE requirements, local hot spots in the equipment room, high-thermal density areas in medium-large equipment rooms, and data centers with limited equipment room area.

 

 

 

Technica Parameter                              

 

Model CRA013A CRA020A CRA040A CRA050A CRA060A
Air supply Front/Side Front/Side Front Front Front
Power supply 380VAC/3Ph/50Hz
Cooling capacity-KW 13.2 26.7 42.6 53.3 63.9
Sensible cooling-KW 13.2 26.7 42.6 53.3 63.9
Compressor
Refrigerant R410A
Quantity 1
Fan
Fan type EC Centrifugal fan
Quantity 4 5 2 3 3
Air volume-m3/h 3200 5000 8800 11000 12500
Heater
Heat type PTC        
Capacity-KW 2 3 6 6 6
Humidification
Capacity-KW 1 1.5 3 3 3

 

 

Factory Details                                         

Precision Air Conditioning Unit In Row For Modular Data Center 6
 
Delivery & Packing                                     

 

 

Cases                                                                  

 

Precision Air Conditioning Unit In Row For Modular Data Center 5

 

 

 

 

 

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2010

  • Total Annual:

    10,000,000.00-10,000,000.00

  • Employee Number:

    100~150

  • Ecer Certification:

    Verified Supplier

Coolnet focuses on the R&D, production and application of data center integrated solutions. It is a service provider in the field of information infrastructure construction, with technology, products and solutions, and is committed to providing customers with products and overall solutions in th... Coolnet focuses on the R&D, production and application of data center integrated solutions. It is a service provider in the field of information infrastructure construction, with technology, products and solutions, and is committed to providing customers with products and overall solutions in th...

+ Read More

Get in touch with us

  • Reach Us
  • Hefei Coolnet power Co., ltd
  • Room 303, 3rd Floor, Building C, Yingte Workshop, West Section of Yanglin Road, High-tech Zone Mechanical and Electrical Industrial Park, Hefei City Anhui Province
  • https://www.precisionacunits.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement