Payment Terms | L/C/Ade/Pellet/Texi Union, MoneyGram, Alipay, and business-to-business payments |
Supply Ability | 999 |
Delivery Time | 3-7 work days |
Ingress protection | IP40 |
communication mode | 485/I2c selectable |
interface | G3/8 |
Output mode | Analog output 1-5V |
precision | ±1.5%F.S |
Storage Temperature | 25°C - 80°C |
Brand Name | Consensic |
Model Number | CAFS5006 |
Place of Origin | WUXI |
View Detail Information
Explore similar products
CAFS3000 service voltage 8~24 V Wide flow range 0 sccm-3000 sccm
CAFS4000 Operating Temperature: -25°C to 85°C Storage Temperature: -40°C to 90°C
CAFS1000C service voltage 14 VDC maximum pressure 0.3 MPa response time 20ms
CAFS5012 joggle NTP 1/2”Calibration method Air, and the 20℃,101.325kPa
Product Specification
Payment Terms | L/C/Ade/Pellet/Texi Union, MoneyGram, Alipay, and business-to-business payments | Supply Ability | 999 |
Delivery Time | 3-7 work days | Ingress protection | IP40 |
communication mode | 485/I2c selectable | interface | G3/8 |
Output mode | Analog output 1-5V | precision | ±1.5%F.S |
Storage Temperature | 25°C - 80°C | Brand Name | Consensic |
Model Number | CAFS5006 | Place of Origin | WUXI |
CAFS5006 communication mode 485/I2c selectable response time 20 ms selectable is a versatile and high-performance flow measurement device designed for a range of applications. This advanced flow meter offers multiple configurations and features tailored to meet diverse measurement needs, making it suitable for both industrial and automotive environments.
Advanced Communication Modes
The CAFS5006 Series supports RS485 and I2C communication protocols, allowing for flexible integration into various systems and easy data transfer.
Customizable Response Time
Offers a selectable response time of 20 ms, which can be adjusted based on the specific requirements of your application for faster or slower flow measurements.
Wide Flow Measurement Range
The flow meter supports a customizable flow range of 20/50/100/200/300 SLPM, suitable for different applications from small-scale to larger flow measurements.
High Measurement Accuracy
Provides accurate measurements with an accuracy of ±1.5% FS, ensuring reliable data for process control and monitoring.
Flexible Power Supply Options
Operates over a wide voltage range of 8 to 24 VDC with a low current consumption of 50 mA, accommodating different power supply configurations.
High Pressure Tolerance
Capable of withstanding a maximum pressure of 0.8 MPa, with customizable specifications to suit various industrial requirements.
Multiple Output Options
Features analog outputs (1-5 VDC) for easy integration into existing systems and for direct measurement readings.
Durable Construction
Built from aluminum alloys with an optional stainless steel construction for enhanced durability and resistance to harsh environments.
High Protection Level
With an IP40 protection rating, the CAFS5006 Series is designed to perform reliably in challenging conditions.
Versatile Calibration Method
Calibrated with air at 0°C and 20°C, 101.325 kPa, ensuring accurate and consistent performance across different conditions.
User-Friendly Design
G3/8 connection mode for easy installation and integration into existing systems.
Functional Items | CAFS5006 Series Mass Flow Meter |
---|---|
Flow Range | 20 / 50 / 100 / 200 / 300 SLPM (customizable) |
Power Supply Voltage | 8~24 VDC, 50 mA |
Accuracy | ±1.5% FS |
Response Time | 20 ms (selectable) |
Maximum Pressure | 0.8 MPa (customizable) |
Communication Mode | RS485 / I2C (selectable) |
Output Method | Analog Output of 1-5 VDC |
Temperature Range | Medium Temperature: -10°C to 65°C |
Protection Level | IP40 |
Calibration Method | Air, 0°C and 20°C at 101.325 kPa |
Material | Aluminum Alloys (Stainless Steel Optional) |
Connection Mode | G3/8 (customizable) |
Industrial Process Control
Ideal for measuring gas flow in various industrial processes, ensuring accurate control and monitoring.
Automotive Testing
Suitable for use in automotive applications for testing and calibrating fuel injection systems and other components.
Environmental Monitoring
Provides reliable flow measurements for environmental control and research applications.
Energy Sector
Used for flow measurement in energy production processes, contributing to efficient energy management.
Pin | Function |
---|---|
1 | NTC (Temperature Sensor) / Empty |
2 | VCC (Power Supply) |
3 | GND (Signal Ground) |
4 | NC (No Connection) |
5 | Output (Flow Measurement Signal) |
Note: The pin configuration may vary based on customer specifications. The above configuration represents a common setup for reference.
Fault Phenomenon | Possible Cause | Solution |
---|---|---|
No Analog Signal | ① Wiring Error | Connect wires correctly according to the instructions |
No Traffic Change | ① Sensor Damage | Check if the sensor is damaged |
② No Air Flow in the Pipeline | Ensure there is air flow in the pipeline | |
Communication Issues | ① Wiring Error | Verify wiring according to the communication instructions |
② Incorrect Parameter Settings | Correctly set parameters according to the communication protocol |
Product Model | Latus Rectum | Joggle | L | H | W | D | Specifications |
---|---|---|---|---|---|---|---|
CAFS 5006 | 6 | 1/4’’ | 83 | 27 | 35 | 6 | 10 / 20 / 30 / 50 units (L / MIN) |
Company Details
Business Type:
Manufacturer,Agent,Seller,Other
Year Established:
2009
Total Annual:
1000-1500
Employee Number:
50~100
Ecer Certification:
Verified Supplier
ConsensicInc. Sensorchipandsolutionprovider Pressuresensor,flowsensor,humidity sensor,etc. China Wuxi Consensic Electronic Technology Co., Ltd Room 214072, B5401, No. 86 Dicui Road, Binhu District, Wuxi City, Jiangsu Province Phone:+86 510.85122279 Fax:+... ConsensicInc. Sensorchipandsolutionprovider Pressuresensor,flowsensor,humidity sensor,etc. China Wuxi Consensic Electronic Technology Co., Ltd Room 214072, B5401, No. 86 Dicui Road, Binhu District, Wuxi City, Jiangsu Province Phone:+86 510.85122279 Fax:+...
Get in touch with us
Leave a Message, we will call you back quickly!