Packaging Details | Wooden Case |
Delivery Time | 7 Working Days |
Payment Terms | T/T L/C |
Supply Ability | 200 sets per month |
Place of Origin | Wuhan Hubei China |
Brand Name | Huaying |
Certification | ISO |
Model Number | Huaying Series |
View Detail Information
Explore similar products
CT PT Tester
CT PT Tester
Current Transformer Analyzer / CT Analyzer
Transformer CT PT Analyzer HYVA 402
Product Specification
Packaging Details | Wooden Case | Delivery Time | 7 Working Days |
Payment Terms | T/T L/C | Supply Ability | 200 sets per month |
Place of Origin | Wuhan Hubei China | Brand Name | Huaying |
Certification | ISO | Model Number | Huaying Series |
CT PT Analyzer HYVA-405
2. Equipment Description:
Tests for Current Transformer: | Tests for Potencial Transformer: |
1 Excitation curve and parameters test
2 Turns ratio test
3 Ratio and phase error test
4 Polarity mark check
5 Winding resistance measurement
6 Secondary loop burden measurement
7 Error line curve test for protection CT
8 Transient CT parameters test
9 CT nameplate guess
10 Saturation hysteresis loop curve measurement
|
1 Turns ratio test
2 Ratio error and phase angle error test
3 Polarity test
4 Secondary burden test
5 Winding resistance test
|
1 CT nameplate check
2 CT parameters check in work burden
3 CT transient parameters analysis
4 CT ratio and phase error calibration
5 PT routine test
|
3.Technical Parameters:
1 Test standards: IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C57.13
2 Power supply: AC220V±10%, 50/60Hz±10%
3 Voltage output: 0.1~180V (AC)
4 Current output: 0.001~5A(RMS)
5 Power output: 500VA
6 Maximum knee voltage measurement: 45KV
7 Current measurement:
Range: 0~10A (automatically change range in 0.1/0.4/2/10A)
Error: <±0.1%+0.01%FS
8 Voltage measurement:
Range: 0~200V (automatically change range in 1V/10V/70V/200V)
Error: < ±0.1%+0.01%FS
9 Turns ratio measurement:
Range:1~35000
1~2000 error<0.05%
2000~5000 error<0.1%
5000~35000 error<0.2%
10 Phase measurement: error: ±2min; resolution: 0.01min
11 Winding resistance measurement:
Range: 0~8kΩ (automatically change range in 2ohm/20ohm/80ohm/800ohm/8kohm)
Error: < 0.2%RDG+0.02%FS
Maximum resolution: 0.1mΩ
12 Temperature measurement:-50~100 Celsius degree; error<3 Celsius degree
|
13 CT Secondary burden:
Range: 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm)
Error: <0.2%RDG+0.02%FS
Maximum resolution: 0.001ohm
14 PT Secondary burden:
Range: 0~80kohm (automatically change range in 800ohm/8kohm/80kohm)
Error :<0.2%RDG+0.02%FS
Maximum resolution: 0.1ohm
15 PT ratio measurement:
Range: 1~35000
1~10000 error<0.1%
10000~35000 error<0.2%
16 PT ratio error measurement: Typical error <0.05%, Maximum Error<0.1%
17 PT phase angle measurement: maximum error < 3min
18 Make evaluation for test results according to selected standards
19 Make word report for test result
20 Make word reports one time for multi-group test records on the PC
21 Calculate the ratio errors and phase angle errors at rated burden and working burden in one time test
22 Compare excitation curves with saved excitation curves in the same window
23 Memory capacity: >1000 groups test results
24 Working condition: temperature: -10℃~50℃; moist: ≤90%
|
4. Product Picture:
Company Details
Business Type:
Manufacturer,Exporter,Seller
Year Established:
1997
Total Annual:
350 0000-400 0000
Employee Number:
100~150
Ecer Certification:
Active Member
Wuhan Huaying Electric Power Tech & Science Co.,ltd, founded in 1997, engaged in the designing, manufacturing and selling of electrical test equipments. Our products include: HV Testing Instruments, Transformer Test Sets, Relay Test Set, Circuit Breaker Test Set, CT/PT Test Set, ... Wuhan Huaying Electric Power Tech & Science Co.,ltd, founded in 1997, engaged in the designing, manufacturing and selling of electrical test equipments. Our products include: HV Testing Instruments, Transformer Test Sets, Relay Test Set, Circuit Breaker Test Set, CT/PT Test Set, ...
Get in touch with us
Leave a Message, we will call you back quickly!