China factories

China factory - Yueqing Vorax Electric CO.,LTD

Yueqing Vorax Electric CO.,LTD

  • China ,Zhejiang
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China GFCI Din Rail Circuit Breaker 15A 10kA Interrupt Rating
China GFCI Din Rail Circuit Breaker 15A 10kA Interrupt Rating

  1. China GFCI Din Rail Circuit Breaker 15A 10kA Interrupt Rating
  2. China GFCI Din Rail Circuit Breaker 15A 10kA Interrupt Rating

GFCI Din Rail Circuit Breaker 15A 10kA Interrupt Rating

  1. MOQ:
  2. Price:
  3. Get Latest Price
UL Listed Yes
Indicator Light Yes
CSA Certified Yes
Electrical life 2000
Trip Type Thermal Magnetic
Amperage Rating 40A
Product Name GFCI Circuit Breaker
Frequency Rating 50/60 Hz
Brand Name HAROK
Model Number VKL003
Place of Origin CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

UL Listed Yes Indicator Light Yes
CSA Certified Yes Electrical life 2000
Trip Type Thermal Magnetic Amperage Rating 40A
Product Name GFCI Circuit Breaker Frequency Rating 50/60 Hz
Brand Name HAROK Model Number VKL003
Place of Origin CHINA
High Light din rail gfci breaker 15ADin Rail 15a gfci breaker10kA din rail gfci breaker

VKL003 GFCI | GROUND FAUL CIRCUIT INTERRUPTER

1. General

VKL003 residual current operated circuit breakers are suitable for lines with AC 50/60Hz, rated voltage 240V, 120V, rated current up to 40A and for purposes of residual current protection, overload and short circuit protection. When any personal electric shock occurs or the circuit leakage current exceeds the predetermined value, the residual current operated circuit breaker can automatically cut off the power supply in a very short period of time, so that the safety of persons and electrical equipment can be operated. The residual current operated circuit breaker can be used for infrequent conversion of lines under normal conditions, and applied under occasions such as industrial, and commercial, high-rise buildings and residential houses.

 

2. Technical parameters

2.1 The tripping characteristic curves are as shown below.

2.2 Basic parameters

  Standard IEC/EN 61009-1
Main Specifications Model No. VKL003
Rated current In 5A, 6A, 10A, 13A, 15A, 16A, 20A, 25A, 30A, 32A, 35A, 40A
Classified by Type of Instantaneous Tripping Type B: (3 ~ 5) In, Type C: (5 ~ 10) In
Poles 1P + N
Type (wave form of the earth leakage sensed) Type AC, Type A
Mechanical features Rated voltage Ue AC240V, AC120V
Frame size rated current In 40A
Rated residual operating current I△n 6mA, 10mA, 30mA, 100mA, 300mA
Rated residual non-operating current I△no 3mA, 5mA, 15mA, 50mA, 150mA
Rated short-circuit breaking capacity Icn 240V: 4500A, 6000A, 10000A 120V: 15000A

Rated residual making and

breaking capacity I△m

500A
Electrical life 2,000
Mechanical life 2,000
Rated impulse withstand voltage Uimp 4000V
Connection From top and bottom, from bottom and top

2.3 The residual current breaking times

In (A) I△n (A) Breaking time when the residual current assumes the following values (s)
I△n 2I△n 5I△n 5A, 10A, 20A, 50A, 100A, 200A, 500A(a) I△t(b)
6~40 0.01, 0.03, 0.1, 0.3 0.1 0.05 0.04 0.04 0.04

a. For tests of 5A, 10A, 20A, 50A, 100A, 200A and 500A, the current values beyond the lower limit of over-current instantaneous tripping are not tested.

B. Tests are done when I△t is equal to the lower limit current of over-current instantaneous tripping of type B and type C.

2.4 The over-current protection characteristics

No. Rated current In (A) Initial state Test current (A) Specified time (t) Expected result Remarks
a 6 ~ 40 Cold state 1.13 In t ≥ 1h Non-tripping  
b Immediately after sequence a 1.45 In t < 1h Tripping Increase to the specified current within 5s after test item a.
c Cold state 2.55 In 1s < t < 60s Tripping  
d Cold state 3 In t ≥ 0.1s Non-tripping Type B
5 In t < 0.1s Tripping
5 In t ≥ 0.1s Non-tripping Type C
10 In t < 0.1s Tripping

 

3. Outline and installation dimensions (mm)

__________________________________________________________________________________________________________________________________________________________________________________________________________

Product Description:

GFCI Circuit Breaker is designed to provide protection from ground fault circuit interruption. The RCBO Type B GFCI Circuit Breaker is a ground fault circuit interrupter that is designed for use with push-in terminals and has a frequency rating of 50/60 Hz. It has a voltage rating of 120/240VAC and is capable of handling 14-2 AWG wire. The trip type is thermal magnetic. This GFCI Circuit Breaker is an effective way to protect against ground fault circuit interruption, providing safety for electrical systems.

 

Features:

  • Product Name: GFCI Circuit Breaker
  • Mounting Type: Plug-in
  • CSA Certified: Yes
  • Indicator Light: Yes
  • Terminal Type: Push-in
  • RCBO Type A: Yes
  • RCBO Type B: Yes
  • GFCI Circuit Breaker: Yes
 

Applications:

HAROK's GFCI Circuit Breakers, model numbers VRL01, VRL02, VRL03, VRL11, VAL003, VKL003, VDL006, and VRL22, are designed to be plug-in circuit breakers with NEMA 1 rating and indicator light. They also have a frequency rating of 50/60 Hz and a wire gauge of 14-2 AWG. These GFCI Circuit Breakers are ideal for use in RCBO Type B and RCBO Circuit Breaker applications. The Residual Current Circuit Breaker (RCCB) feature provides reliable protection from electric shock and other hazards. HAROK's GFCI Circuit Breakers are designed for optimal safety, stability, and longevity.

 

Technical Parameters:

Product Name Specifications
GFCI Circuit Breaker Mounting Type: Plug-in
Interrupt Rating: 10kA
Indicator Light: Yes
CSA Certified: Yes
Trip Type: Thermal Magnetic
Frequency Rating: 50/60 Hz
NEMA Rating: NEMA 1
Voltage Rating: 120/240VAC
Number of Poles: 1 Pole
RCBO Circuit Breaker: Type A, Type B, Type C, Type D, Type E
 

Customization:

GROUND FAULT CIRCUIT INTERRUPTER CIRCUIT BREAKER

  • Brand Name: HAROK
  • Model Numbers:  VKL003
  • Place of Origin: CHINA
  • Trip Type: Thermal Magnetic
  • Product Name: GFCI Circuit Breaker
  • Terminal Type: Push-in
  • Indicator Light: Yes
  • Wire Gauge: 14-2 AWG
 

Packing and Shipping:

Packaging and Shipping for GFCI Circuit Breaker

GFCI Circuit Breaker will be packaged and shipped in accordance with the following procedures:

  • The product will be securely packaged in a cardboard box with foam padding.
  • The box will be labeled with the product name, model number, and the company logo.
  • The box will also include any necessary user manuals and product warranty information.
  • The box will be placed in a larger box and shipped via a reputable courier service.
  • The shipment will be tracked and insured for delivery.

GFCI | GROUND FAUL CIRCUIT INTERRUPTER

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2003

  • Employee Number:

    >100

  • Ecer Certification:

    Verified Supplier

  YUEQING VORAX ELECTRIC CO., LTD (hereinafter referred to as "VORAX"), founded in 2003, has established itself as a prominent player in the low voltage electrics industry in China. With a prime location in Liushi Town, Yueqing city, Zhejiang Province, VORAX benefits from being s...   YUEQING VORAX ELECTRIC CO., LTD (hereinafter referred to as "VORAX"), founded in 2003, has established itself as a prominent player in the low voltage electrics industry in China. With a prime location in Liushi Town, Yueqing city, Zhejiang Province, VORAX benefits from being s...

+ Read More

Get in touch with us

  • Reach Us
  • Yueqing Vorax Electric CO.,LTD
  • Liuhuang Road, Liushi Town, Yueqing City, Zhejiang Province
  • https://www.rccbbreaker.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!