Packaging Details | PAPER CARTON |
Delivery Time | 4-6 weeks after payment |
Payment Terms | FOB NINGBO or SHANGHAI |
Supply Ability | 100,000 PCS PER MONTH |
Dimension | According To The Product Model |
Operating Environment Temperature | -25℃~+50℃ |
Certificate | NF, SEMKO, VDE, KEMA |
Installation Method | Cable/Pin-type busbar |
Rated Current | 6A-100A |
Weight | According To The Product Model |
Rated Frequency | 50/60Hz |
Material | PA66 |
Brand Name | HAROK |
Model Number | VKL11 |
Place of Origin | CHINA |
Certification | NF, SEMKO, VDE, KEMA |
View Detail Information
Explore similar products
VML01 Earth Leakage Circuit Breaker With Inmetro Certificate
VFL001 ELCB Earth Leakage Circuit Breaker TYPE AC, TYPE A, TYPE ASi
VML01 Earth Leakage Circuit Breaker Type A Type AC Type ASi
VKL11 Earth Leakage Circuit Breaker Type EV
Product Specification
Packaging Details | PAPER CARTON | Delivery Time | 4-6 weeks after payment |
Payment Terms | FOB NINGBO or SHANGHAI | Supply Ability | 100,000 PCS PER MONTH |
Dimension | According To The Product Model | Operating Environment Temperature | -25℃~+50℃ |
Certificate | NF, SEMKO, VDE, KEMA | Installation Method | Cable/Pin-type busbar |
Rated Current | 6A-100A | Weight | According To The Product Model |
Rated Frequency | 50/60Hz | Material | PA66 |
Brand Name | HAROK | Model Number | VKL11 |
Place of Origin | CHINA | Certification | NF, SEMKO, VDE, KEMA |
High Light | UL1053 Earth Leakage Circuit Breaker ,ELCB circuit breaker UL1053 ,100A Earth Leakage Circuit Breaker |
VKL11 Earth Leakage Circuit Breaker(ELCB) UL1053
1. General
1.1 Function
Control electric circuits.
Protect people against indirect contacts and additional protection against direct contacts.
Protect installations against fire hazard due to insulation faults.
Residual current circuit breakers are used in housing, tertiary sector and industry.
1.2 Selection
Detectable wave form
ELCB Type | Suitable for electrical networks with | ||
---|---|---|---|
Pulsated DC current | Harmonics | Switching surges | |
AC CLASS | No | No | No |
A CLASS | Yes | No | No |
S, ASi CLASS | Yes | Yes | Yes |
A Class ELCB may not work satisfactorily in electrical network distributed by harmonics & switching transients and may give nuisance triping.
AC class
Tripping is ensured for slowly increasing sinusoidal AC residual currents
A class
Tripping is ensured for sinusoidal AC residual currents and for pulsed DC residual currents, whether applied suddenly or increasing slowly.
ASi Type - Full type A features + Si: Super immused (High immunity to unwanted tripping)
Tripping is ensured not only for sinusoidal AC residual currents but also for pulsed DC residual currents whether applied suddenly or increasing slowly. S, G/SI type with filters against spurious tripping caused by harmonics and transient surges. With the impact of 8/20us surge 3000A, this high immunity RCCB will still be in stable status.
Note: Our ASi type includes G/KV function and Si function.
1.3 Approvals and certificates
We certify that the ELCB has been tested for the following routine tests as per IS: 12640 (Part 1):2016 and found to be complying
with the requirements.
1. Verification of the operating characteristic as per Seq. - D0 CL9.9
2. Verification of the operation of the test device at the limits of rated voltage as per Seq. - D1 CL9.16
3. High Voltage Test as per D.3 of Annex D
4. Test for standard values of break time and non- actuating time as per CL 5.3.12 (table -1)
Tripping sensitivity
10mA - precision instrument leakage protection and bathroom use.
30mA - additional protection against direct contact.
100mA - co-ordinated with the earth system according to the formula I△n < 50/R, to provide protection against indirect contacts;
300mA/500mA - protection against indirect contacts, as well as fire hazard.
Tripping time
Instantaneous
It ensures instantaneous tripping(without time-delay).
Short time delay Si, G, KV
It ensures any tripping at least 10ms.
Si: Super immunised (High immunity to unwanted tripping).
Selective
It ensures total discrimination with a non selective ELCB(RCCB) placed downstream.
ELCB | Earth Leakage Circuit Breaker
2. Technical parameters
Standard | IEC/EN 61008-1 AS/NZS61008.1 | |
Electrical features | Model No. | VKL11 |
Poles | 2P, 4P | |
Rated current In | 16A, 25A, 32A, 40A, 63A, 80A, 100A | |
Rated Sensitivity I△n | 10mA(2P/4P 16A,25A.32A/40A), 30mA, 100mA, 300mA | |
Rated voltage Ue | 2P: 240V 4P: 415V | |
Insulation voltage Ui | 415V | |
Rated frequency | 50/60 Hz | |
Rated residual making and breaking capacity I△m | 1500A | |
Short-circuit current Inc=I△c | 6000A, 10000A | |
Type (wave form of the earth leakage sensed) | A, AC, ASi | |
break time under I△n | ≤0.1s(Normal type), 10ms~300ms(ASi type). 150ms~500ms(S type) | |
Rated impulse withstand voltage(1.2/50) Uimp | 4kV | |
Dielectric test voltage at ind. Freq. for 1 min | 2.5 | |
Pollution degree | 2 | |
Mechanical features | Electrical life | ≥2000 |
Mechanical life | ≥2000 | |
Fault current indicator | Yes | |
Terminal protection degree | IP20 | |
Ambient temperature (with daily average≤35℃) | -25℃ to 50℃ | |
Storage temperate | -30℃ to 70℃ | |
Installation | Terminal connection type | Cable/Pin-type busbar |
Terminal size top/bottom for cable | 25-35 mm² | |
18-3/18-2 AWG | ||
Terminal size top/bottom for busbar | 10/16 mm² | |
18-8/18-5 AWG | ||
Tightening torque | 2.5 N·m | |
22 In-Ibs. | ||
Mounting | On DIN rail EN 60715 (35mm) by means of fast clip device | |
Connection | From top and bottom |
3. Outline and installation dimensions (mm)
ELCB | Earth Leakage Circuit Breaker
ELCB Earth Leakage Circuit Breaker is a device designed to provide reliable protection against earth leakage and short circuit current. It is made of high-grade PA66 materials and is able to withstand temperatures ranging from -25℃ to +50℃. It is also certified with NF, SEMKO, VDE, and KEMA. The insulation voltage is ≥2KV and the rated current is from 6A to 100A. ELCB Earth Leakage Circuit Breaker is highly reliable and is able to effectively protect against electrical hazards.
ELCB Earth Leakage Circuit Breaker
Brand Name: HAROK
Model Number: VKL11
Place of Origin: CHINA
Certification: NF, SEMKO, VDE, KEMA
Minimum Order Quantity: 1000
Packaging Details: PAPER CARTON
Delivery Time: 4-6 weeks after payment
Payment Terms: FOB NINGBO or SHANGHAI
Supply Ability: 100,000 PCS PER MONTH
Installation Method: Cable/Pin-type busbar
Dimension: According To The Product Model
Protection Grade: IP20
Rated Current: 6A-100A
Keywords: ELCB Type A Type AC Type ASi, ELCB UL1053
ELCB Earth Leakage Circuit Breaker must be packaged and shipped according to the following instructions:
Company Details
Business Type:
Manufacturer
Year Established:
2003
Employee Number:
>100
Ecer Certification:
Verified Supplier
YUEQING VORAX ELECTRIC CO., LTD (hereinafter referred to as "VORAX"), founded in 2003, has established itself as a prominent player in the low voltage electrics industry in China. With a prime location in Liushi Town, Yueqing city, Zhejiang Province, VORAX benefits from being s... YUEQING VORAX ELECTRIC CO., LTD (hereinafter referred to as "VORAX"), founded in 2003, has established itself as a prominent player in the low voltage electrics industry in China. With a prime location in Liushi Town, Yueqing city, Zhejiang Province, VORAX benefits from being s...
Get in touch with us
Leave a Message, we will call you back quickly!