Rated making and breaking capacity Im 1500A
Degree of protection IP20
Mode of operation Voltage Dependent
Rated current In 16A, 25A, 32A, 40A, 63A, 80A, 100A
Rated residual operating current I△n 30mA, 100mA, 300mA, 500mA(Instantaneous & K-short Time Delayed (G, ASi)); 100mA, 300mA, 500mA (100mA, 300mA, 500mA)
Mechanical Endurance ≥ 4000
Product Name RCCB TYPE B
Electrical Endurance ≥ 2000
Brand Name HAROK
Model Number VKL11
Place of Origin CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Rated making and breaking capacity Im 1500A Degree of protection IP20
Mode of operation Voltage Dependent Rated current In 16A, 25A, 32A, 40A, 63A, 80A, 100A
Rated residual operating current I△n 30mA, 100mA, 300mA, 500mA(Instantaneous & K-short Time Delayed (G, ASi)); 100mA, 300mA, 500mA (100mA, 300mA, 500mA) Mechanical Endurance ≥ 4000
Product Name RCCB TYPE B Electrical Endurance ≥ 2000
Brand Name HAROK Model Number VKL11
Place of Origin CHINA
High Light Super immunity RCCB TYPE BSuper immunity rccb device1500A RCCB TYPE B

Super immunity RCCB TYPE B

 

1. General

 

1.1 Function

VKL11B RCCB and VKL11B+ RCCB is appearance design, compact structure, good reliability, and high safety. They are universal residual current circuit breaker.

Residual current circuit breaker type B are suitable for domestic as well as industrial applications, where are used frequency inverters, PV plant, EV chargers and similar elements. B type provides a sensitivity to residual AC, pulsating and smooth DC current, together with high frequencies up to 1 kHz.

Residual current circuit breaker type B+ meet full type B feature , with additional tripping values are defined up to 20KHZ and they are below 420mA.

They are based on electronic technology, which brings advantages of more accurate measuring of residual current and, as a consequence, reduction of unwanted tripping. These devices also do not suffer with magnetization of the tripping unit.

 

1.2 Selection

 

Detectable wave form

 

Type B

Tripping is ensured for sinusoidal AC residual currents pulsed DC residual currents, alternating residual sinusoidal currents up to 1000Hz, pulsating direct residual currents and for smooth direct residual currents, whether applied suddenly or increasing slowly.

 

Type B+

Meet full type B feature , with additional tripping values are defined up to 20KHZ and they are below 420mA

 

Tripping sensitivity

30mA - additional protection against direct contact.

100mA - co-ordinated with the earth system according to the formula IΔn<50/R, to provide protection against indirect contacts;

300mA - protection against indirect contacts, as well as fire hazard.

 

Tripping time

Instantaneous It ensures instantaneous tripping(without time-delay).

Short time delay

Selective (time delay)

 

1.3 Approvals and certificates

 

 

RCCB | Residual Current Circuit Breaker

 

2. Technical parameters

 

Type B B+
Electrical
Design according to IEC/EN 62423, IEC/EN 61008-1, OVE E8601
  VDE 0664-400
Current test marks as printed onto the device
Rated voltage Un

2P: 230/240V AC

4P: 400/415V AC

Rated frequency fn 50/60Hz
Mode of operation

"A type functionality: voltage independent

B and B+ type functionality: voltage dependent"

Operation voltage electronic 50 – 264V AC
Voltage range test circuit

2P: 184 – 264V AC

4P: 184 – 440V AC

Rated current In 16A, 25A, 32A, 40A, 63A, 80A, 100A

Rated residual

operating

current I△n

Instantaneous 30mA, 100mA, 300mA, 500mA 30mA, 100mA, 300mA
K-short time delayed (G, ASi) 30mA, 100mA, 300mA, 500mA 30mA, 100mA, 300mA
S- selective 100mA, 300mA, 500mA 100mA, 300mA
Sensitivity Alternating, pulsed and smooth direct currents
High frequency up to 1 kHZ High frequency up to 20kHZ
Rated insulation voltage Ui 500 V
Rated impulse withstand voltage Uimp 4 kV (1.2/50μs)
Rated conditional short-circuit current Inc 10 kA
Rated making and breaking capacity Im 1500 A
Peak withstand current

3 kA (8/20 μs) surge current proof

5 kA (8/20 μs) surge current proof for type S

Electrical isolation > 4 mm contact space

Maximum back-up fuse

In = 16-100A

Short circuit and overload protection

100 A gG/gL

Endurance

(operating cycles)

electrical components ≥ 2000
mechanical components ≥ 4000
Mechanical
Degree of protection IP20
Upper and lower terminals open mounted / lift terminals
Terminal capacity 1 - 25 mm2
Terminal torque 2 - 2.5 Nm
Busbar thickness 0.8 - 2 mm
Operating temperature -25°C ... +55°C
Storage- and transport temperature -40°C ... +70°C
Resistance to climatic conditions IEC/EN 61008
Contact position indicator mechanical red / green
Supply possibility top or bottom
Mounting position any

 

 

3. Special features regarding the use of SIQUENCE universal current-sensitive residual current circuit breaker (Type B and Type B+)

 

3.1 Applications

Typical applications that are vulnerable to smooth DC residual currents:

- Frequency converters with a three-phase connection

- Medical equipment such as X-ray equipment or CT machines

- Photovoltaic or UPS systems

- Connection points (wall boxes, charging stations) for electric vehicles

- Elevator controllers

- Pipeline trace heating

- Test setups in laboratories

- Construction sites in accordance with BGI 608 information leaflet (Electronic equipment on construction sites)

- Charging stations for battery-powered forklift trucks

- Cranes of all kinds

- Mixing plants if relevant loads are connected

- Variable-speed machine tools, such as milling and grinding machines or lathes

 

4. Wiring diagrams

 

 

5. Tripping characteristics

 

B type

 

 

 

 

 

 

 

 

 

 

 

 

 

6. Dimensions (mm)

 

Product Description:

The Super immunised RCCB (Residual Current Circuit Breaker) Type B is a high-immunity device designed to detect and protect people and equipment from electric shock and fire caused by indirect contact, leakage and earth fault current. This product is designed to meet international safety standards including IEC/EN 62423, IEC/EN 61008-1, and OVE E8601. It has a rated frequency of 50/60Hz and a rated voltage of 2P 230/240V~; 4P 400/415V~. The rated current of this Type B RCCB is from 16A to 100A with a degree of protection of IP20.
 

Features:

  • Product Name: RCCB TYPE B
  • Rated voltage Un: 2P 230/240V~; 4P 400/415V~
  • Rated making and breaking capacity Im: 1500A
  • Mode of operation: Voltage Dependent
  • Standard: IEC/EN 62423, IEC/EN 61008-1, OVE E8601
  • Busbar thickness: 0.8 - 2 Mm
  • Residual Current Circuit Breaker (RCCB) for reliable protection against indirect contact
 

Applications:

HAROK's VKL11 High immunity RCCB is a reliable device of degree of protection IP20, with rated current In of 16A, 25A, 32A, 40A, 63A, 80A, 100A and rated frequency of 50/60Hz. It is manufactured in CHINA, and certified to IEC/EN 62423, IEC/EN 61008-1, OVE E8601. It has a rated impulse withstand voltage of 4 KV (1.2/50μs). The product is designed to be used in diverse applications with high immunity demands, such as commercial, industrial, and residential electrical installations.

 

Technical Parameters:

Parameter Value
Electrical Endurance ≥ 2000
Rated making and breaking capacity Im 1500A
Mode of operation Voltage Dependent
Sensitivity Alternating, Pulsed And Smooth Direct Currents (High Frequency Up To 1 KHZ)
Rated residual operating current I△n 30mA, 100mA, 300mA, 500mA (Instantaneous & K-short Time Delayed (G, ASi)); 100mA, 300mA, 500mA (100mA, 300mA, 500mA)
Rated Frequency 50/60Hz
Rated current In 16A, 25A, 32A, 40A, 63A, 80A, 100A
Rated voltage Un 2P 230/240V~; 4P 400/415V~
Busbar thickness 0.8 - 2 Mm
Product Name RCCB TYPE B
Keywords Residual Current Circuit Breaker, Super immunised RCCB
 

Customization:

RESIDUAL CURRENT CIRCUIT BREAKER (RCCB) TYPE B

Brand Name: HAROK

Model Number: VKL11

Place of Origin: CHINA

Rated Making and Breaking Capacity Im: 1500A

Degree of Protection: IP20

Standard: IEC/EN 62423, IEC/EN 61008-1, OVE E8601

Mode of Operation: Voltage Dependent

Busbar Thickness: 0.8 - 2 Mm

Our RCCB TYPE B is a super immunised Residual Current Circuit Breaker that provides protection against electric shock and fire caused by indirect contacts. It is designed and manufactured with Brand Name HAROK, Model Number VKL11. It has a rated making and breaking capacity of 1500A and IP20 Degree of Protection. This RCCB meets the standards of IEC/EN 62423, IEC/EN 61008-1, OVE E8601 and works in a Voltage Dependent mode. The Busbar Thickness is 0.8 - 2 Mm.

 

Packing and Shipping:

The Packaging and Shipping of RCCB TYPE B is as follows:

  • The product is packaged in a durable, well-designed cardboard box.
  • The product is placed in a foam padded container to ensure that it is kept safe during shipping.
  • The product is shipped using a reputable delivery service, such as FedEx, UPS or DHL.
  • The product is insured during shipping and is delivered to the customer with a tracking number.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2003

  • Employee Number:

    >100

  • Ecer Certification:

    Verified Supplier

  YUEQING VORAX ELECTRIC CO., LTD (hereinafter referred to as "VORAX"), founded in 2003, has established itself as a prominent player in the low voltage electrics industry in China. With a prime location in Liushi Town, Yueqing city, Zhejiang Province, VORAX benefits from being s...   YUEQING VORAX ELECTRIC CO., LTD (hereinafter referred to as "VORAX"), founded in 2003, has established itself as a prominent player in the low voltage electrics industry in China. With a prime location in Liushi Town, Yueqing city, Zhejiang Province, VORAX benefits from being s...

+ Read More

Get in touch with us

  • Reach Us
  • Yueqing Vorax Electric CO.,LTD
  • Liuhuang Road, Liushi Town, Yueqing City, Zhejiang Province
  • https://www.rccbbreaker.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement