VKL11 RCCB Type B+

  1. MOQ:
  2. Price:
  3. Get Latest Price
Rated making and breaking capacity Im 1500A
Degree of protection IP20
Rated voltage Un 2P 230/240V~; 4P 400/415V~
Mode of operation Voltage Dependent
Standard IEC/EN 62423, IEC/EN 61008-1, OVE E8601
Mechanical Endurance ≥ 4000
Busbar thickness 0.8 - 2 Mm
Rated Frequency 50/60Hz
Brand Name HAROK
Model Number VKL11
Place of Origin CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Rated making and breaking capacity Im 1500A Degree of protection IP20
Rated voltage Un 2P 230/240V~; 4P 400/415V~ Mode of operation Voltage Dependent
Standard IEC/EN 62423, IEC/EN 61008-1, OVE E8601 Mechanical Endurance ≥ 4000
Busbar thickness 0.8 - 2 Mm Rated Frequency 50/60Hz
Brand Name HAROK Model Number VKL11
Place of Origin CHINA
High Light water heater rccb Type B+Voltage Dependent water heater rccb1500A 2pole rccb

VKL11 RCCB Type B+

 

1. General

 

1.1 Function

 

A residual current circuit breaker (RCCB) is an electrical device that is designed to protect against electrical shock caused by ground faults. It works by detecting any imbalance in the electrical current flowing through a circuit and immediately shutting off the power to prevent any potential injury or damage. RCCBs are particularly important in areas where water and electricity are in close proximity, such as bathrooms and kitchens. They are also commonly used to provide additional safety protection in damp or wet locations, as well as in industrial settings where high voltage or high current circuits are used. Overall, RCCBs provide a crucial layer of protection against electrical hazards and are an essential component of any safe and effective electrical system.

 

VKL11B RCCB and VKL111B+ RCCB is appearance design, compact structure, good reliability, and high safety. They are universal residual current circuit breaker.

 

Residual current circuit breaker type B are suitable for domestic as well as industrial applications, where are used frequency inverters, PV plant, EV chargers and similar elements. B type provides a sensitivity to residual AC, pulsating and smooth DC current, together with high frequencies up to 1 kHz.

 

Residual current circuit breaker type B+ meet full type B feature , with additional tripping values are defined up to 20KHZ and they are below 420mA.

 

They are based on electronic technology, which brings advantages of more accurate measuring of residual current and, as a consequence, reduction of unwanted tripping. These devices also do not suffer with magnetization of the tripping unit.

1.2 Selection

 

Detectable wave form

 

Type B

Tripping is ensured for sinusoidal AC residual currents pulsed DC residual currents, alternating residual sinusoidal currents up to 1000Hz, pulsating direct residual currents and for smooth direct residual currents, whether applied suddenly or increasing slowly.

 

Type B+

Meet full type B feature , with additional tripping values are defined up to 20KHZ and they are below 420mA

 

Tripping sensitivity

30mA - additional protection against direct contact.

100mA - co-ordinated with the earth system according to the formula IΔn<50/R, to provide protection against indirect contacts;

300mA - protection against indirect contacts, as well as fire hazard.

 

Tripping time

Instantaneous It ensures instantaneous tripping(without time-delay).

Short time delay

Selective (time delay)

 

1.3 Approvals and certificates

 

 

RCCB | Residual Current Circuit Breaker

 

2. Technical parameters

 

Type B B+
Electrical
Design according to IEC/EN 62423, IEC/EN 61008-1, OVE E8601
  VDE 0664-400
Current test marks as printed onto the device
Rated voltage Un

2P: 230/240V AC

4P: 400/415V AC

Rated frequency fn 50/60Hz
Mode of operation

"A type functionality: voltage independent

B and B+ type functionality: voltage dependent"

Operation voltage electronic 50 – 264V AC
Voltage range test circuit

2P: 184 – 264V AC

4P: 184 – 440V AC

Rated current In 100A

Rated residual

operating

current I△n

Instantaneous 30mA, 100mA, 300mA, 500mA 30mA, 100mA, 300mA
K-short time delayed (G, ASi) 30mA, 100mA, 300mA, 500mA 30mA, 100mA, 300mA
S- selective 100mA, 300mA, 500mA 100mA, 300mA
Sensitivity Alternating, pulsed and smooth direct currents
High frequency up to 1 kHZ High frequency up to 20kHZ
Rated insulation voltage Ui 500 V
Rated impulse withstand voltage Uimp 4 kV (1.2/50μs)
Rated conditional short-circuit current Inc 10 kA
Rated making and breaking capacity Im 1500 A
Peak withstand current

3 kA (8/20 μs) surge current proof

5 kA (8/20 μs) surge current proof for type S

Electrical isolation > 4 mm contact space

Maximum back-up fuse

In = 16-100A

Short circuit and overload protection

100 A gG/gL

Endurance

(operating cycles)

electrical components ≥ 2000
mechanical components ≥ 4000
Mechanical
Degree of protection IP20
Upper and lower terminals open mounted / lift terminals
Terminal capacity 1 - 25 mm2
Terminal torque 2 - 2.5 Nm
Busbar thickness 0.8 - 2 mm
Operating temperature -25°C ... +55°C
Storage- and transport temperature -40°C ... +70°C
Resistance to climatic conditions IEC/EN 61008
Contact position indicator mechanical red / green
Supply possibility top or bottom
Mounting position any

 

 

3. Special features regarding the use of SIQUENCE universal current-sensitive residual current circuit breaker (Type B and Type B+)

 

3.1 Applications

Typical applications that are vulnerable to smooth DC residual currents:

- Frequency converters with a three-phase connection

- Medical equipment such as X-ray equipment or CT machines

- Photovoltaic or UPS systems

- Connection points (wall boxes, charging stations) for electric vehicles

- Elevator controllers

- Pipeline trace heating

- Test setups in laboratories

- Construction sites in accordance with BGI 608 information leaflet (Electronic equipment on construction sites)

- Charging stations for battery-powered forklift trucks

- Cranes of all kinds

- Mixing plants if relevant loads are connected

- Variable-speed machine tools, such as milling and grinding machines or lathes

 

4. Wiring diagrams

 

 

5. Tripping characteristics

 

B type

 

 

 

 

 

 

 

 

 

 

 

 

 

6. Dimensions (mm)

 

Product Description:

The High immunity RCCB TYPE B is a Voltage Dependent RCCB with rated impulse withstand voltage Uimp of 4 KV (1.2/50μs). This Super immunised RCCB has a busbar thickness of 0.8 - 2 Mm and rated frequency of 50/60Hz. It is capable of providing high reliability and superior protection against electric shock and providing a safe environment. The RCCB TYPE B is the perfect choice for any application where safety is a priority.

 

Features:

  • Product Name: RCCB TYPE B (Residual Current Circuit Breaker Type B)
  • Electrical Endurance: ≥ 2000
  • Mechanical Endurance: ≥ 4000
  • Degree of protection: IP20
  • Busbar thickness: 0.8 - 2 Mm
  • Sensitivity: Alternating, Pulsed and Smooth Direct Currents (High Frequency up to 1 KHZ)
 

Applications:

HAROK's VKL11 Residual Current Circuit Breaker (RCCB) Type B is a reliable and trusted device designed to protect people from electric shock and fire hazards caused by earth leakage. It is certified to comply with IEC/EN 62423, IEC/EN 61008-1, and OVE E8601 standards and has a rated impulse withstand voltage Uimp of 4 KV (1.2/50μs). It is rated with a voltage of 2P 230/240V~; 4P 400/415V~ and an insulation voltage Ui of 500V. In addition, its rated residual operating current I△n is 30mA, 100mA, 300mA, and 500mA (Instantaneous & K-short Time Delayed (G, ASi)), and 100mA, 300mA, and 500mA (100mA, 300mA, 500mA). It is suitable for a wide range of applications and is ideal for protecting against electric shock and fire risks caused by earth leakage. Its reliable design and high-quality components make it an excellent choice for residential, commercial, and industrial applications.

 

Technical Parameters:

Product Name RCCB TYPE B
Busbar thickness 0.8 - 2 Mm
Electrical Endurance ≥ 2000
Rated impulse withstand voltage Uimp 4 KV (1.2/50μs)
Rated Frequency 50/60 Hz
Rated making and breaking capacity Im 1500A
Rated residual operating current I△n 30mA, 100mA, 300mA, 500mA (Instantaneous & K-short Time Delayed (G, ASi)); 100mA, 300mA, 500mA (100mA, 300mA, 500mA)
Mode of operation Voltage Dependent
Rated insulation voltage Ui 500V
Sensitivity Alternating, Pulsed And Smooth Direct Currents (High Frequency Up To 1 KHZ)
 

Customization:

HAROK VKL11 High Immunity RCCB
  • Brand Name: HAROK
  • Model Number: VKL11
  • Place of Origin: CHINA
  • Rated Frequency: 50/60Hz
  • Mechanical Endurance: ≥ 4000
  • Rated insulation voltage Ui: 500V
  • Rated residual operating current I△n: 30mA, 100mA, 300mA, 500mA (Instantaneous & K-short Time Delayed (G, ASi)); 100mA, 300mA, 500mA (100mA, 300mA, 500mA)
  • Standard: IEC/EN 62423, IEC/EN 61008-1, OVE E8601

HAROK VKL11 High Immunity RCCB is a type B residual current circuit breaker, which is designed in accordance with IEC/EN 62423, IEC/EN 61008-1, and OVE E8601 standards. It has a rated frequency of 50/60 Hz and a rated insulation voltage of 500V. Its mechanical endurance is ≥ 4000, and its rated residual operating current is I△n: 30mA, 100mA, 300mA, 500mA (Instantaneous & K-short Time Delayed (G, ASi)); 100mA, 300mA, 500mA (100mA, 300mA, 500mA).

 

Packing and Shipping:

Packaging and Shipping for RCCB TYPE B:

We package RCCB TYPE B in a sturdy cardboard box to ensure safe delivery. The box is filled with foam to provide an extra layer of protection. The shipping method chosen will depend on the size and weight of the shipment, and may include air, land or sea transport.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2003

  • Employee Number:

    >100

  • Ecer Certification:

    Verified Supplier

  YUEQING VORAX ELECTRIC CO., LTD (hereinafter referred to as "VORAX"), founded in 2003, has established itself as a prominent player in the low voltage electrics industry in China. With a prime location in Liushi Town, Yueqing city, Zhejiang Province, VORAX benefits from being s...   YUEQING VORAX ELECTRIC CO., LTD (hereinafter referred to as "VORAX"), founded in 2003, has established itself as a prominent player in the low voltage electrics industry in China. With a prime location in Liushi Town, Yueqing city, Zhejiang Province, VORAX benefits from being s...

+ Read More

Get in touch with us

  • Reach Us
  • Yueqing Vorax Electric CO.,LTD
  • Liuhuang Road, Liushi Town, Yueqing City, Zhejiang Province
  • https://www.rccbbreaker.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement