China Backup Power Supply Generator Load Bank Testing Equipment Three Phase
China Backup Power Supply Generator Load Bank Testing Equipment Three Phase

  1. China Backup Power Supply Generator Load Bank Testing Equipment Three Phase
  2. China Backup Power Supply Generator Load Bank Testing Equipment Three Phase

Backup Power Supply Generator Load Bank Testing Equipment Three Phase

  1. MOQ: ONE SET
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability 20 SETS ONE MONTH
Delivery Time ONE MONTH AFTER GET DEPOSIT
Packaging Details WOODEN CASE
Resistive load 500KW
Load Tolerance ±3%
Control Power 380VAC/50Hz, 3 phase 4 line
Insulation F
Altitude ≤1500 meter
name generator load bank testing equipment
Brand Name KAIXIANG
Model Number AC400-500KW
Certification ISO9001
Place of Origin HEBEI CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram Supply Ability 20 SETS ONE MONTH
Delivery Time ONE MONTH AFTER GET DEPOSIT Packaging Details WOODEN CASE
Resistive load 500KW Load Tolerance ±3%
Control Power 380VAC/50Hz, 3 phase 4 line Insulation F
Altitude ≤1500 meter name generator load bank testing equipment
Brand Name KAIXIANG Model Number AC400-500KW
Certification ISO9001 Place of Origin HEBEI CHINA
High Light resistance load bankgenset load bank

Power bank 500Kw Load Bank 3 Phase For Backup Power Supply Generator
 
Product Description 
 
Automatic AC load bank main used to test the capability and aging degree for high-power ups on-line, inverter, switch power and diesel generator set for electric power, telecom department and manufacturer. It can ensure the reliability of constant power charge that adopts uniformly stepped power input, energy consumption work model and forced air-cooling model. It is of high power density, no red hot phenomenon and automatic protection function overheated. It can’t be overheated and broken when the fans stop working. The complete machine can be operated simply and maintain convenient that adopts module design. It can test voltage and current according to client’s request, and provide scientific test measures for high-power AC equipment.
 
Technical Parameter 

 

Rating Voltage/Frequency 400VAC/50Hz, 3 phase 4 wire,
Rated Load Power Resistive load: 500kW
Installed Capacity Resistive load: 500kW
Load Step 1,2,2,5,10,10,20,50,100,100,200kW
PF(Power Factor) 1
Load Tolerance (each step) ±5%
Load Tolerance(overall) ±3%
Display Precision 0.5 class
Control Power 380VAC/50Hz, 3 phase 4 wire,
Wire Connection

Load power supply input——Copper bar (star coupling)
Control power supply input——terminal block

Insulation F
Protection Grade IP21
Way of Working Continuous Working
Casing Dimensions and Cooling about 1550*1250*1680mm (length*width*height) Forced air cooling,Horizontal inlet air,Vertical cooling
Weight About 750kgs/set
Transportation Hoisting, there are lifting lug in top of casing
Casing Color Grey(RAL7035)
Ambient Temperature -10℃~+50℃
Relative Humidity ≤95%
Altitude ≤1500 meter
Atmospheric Pressure 86~106kPa
Contactor Schneider
Fuse DELIXI
MCU INFINEON
Data processing software Kaixiang(self-developed)
Alloy Resistance Kaixiang(self-developed)

 
Product Advantage
 

Communication type: through RS232, RS485

Load mode: manual load or automatic load.

Manual load: input power and power factor.

Automatic load: User can set several periods of power and time, and in turn of 0%→25%→50%→75%→100%, etc preset order to make automatic load testing.

 
Application

 

Manufacturers of standby power generators commonly use load banks to test and tune newly assembled units. When the generator has been set up in a test cell within the factory, a test engineer uses the load bank to apply a discrete, selectable electrical load to the generator and measure the response stability and endurance. During this process, the test engineer calibrates and adjusts the generator performance to ensure it meets the intended product specifications and tolerances.

 


Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Trading Company,Seller

  • Year Established:

    1994

  • Total Annual:

    10000000-15000000

  • Employee Number:

    120~130

  • Ecer Certification:

    Active Member

Kaixiang intelligent power detection technology is the Chinese industry leader dedicated to providing load testing and maintenance of all types of power, to avoid accidents and economic losses due to power failure. As a national high-tech enterprises, science and technology to create the industry... Kaixiang intelligent power detection technology is the Chinese industry leader dedicated to providing load testing and maintenance of all types of power, to avoid accidents and economic losses due to power failure. As a national high-tech enterprises, science and technology to create the industry...

+ Read More

Get in touch with us

  • Reach Us
  • Hebei Kaixiang Electrical Technology Co., Ltd
  • No33 Wangshan Road, Green Island Economic Development Zone, Shijiazhuang, China
  • https://www.resistive-loadbank.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement