Payment Terms | T/T, Western Union |
Supply Ability | 100 units/ month |
Delivery Time | 35~40days |
Packaging Details | Stretch film +pallet for container loading |
Tube material | Cu |
Fin material | Al |
Frame material | SUS 304/ G.I./ AL |
Fan brand | ZIEHL-ABEGG Is OK |
Options A | Wet curtain or spray system |
Options B | OEM is OK |
Application | Data center |
Brand Name | Shenglin |
Model Number | SHSL-D2 Series |
Certification | CE and RoHs |
Place of Origin | China |
View Detail Information
Explore similar products
5~800kw Submerging Mining Farm Cooling System Bitcoin Cooler Unit
Blockchain Miners Liquid Submersion Cooling System Dry Cooling Tower
CE Submerged Cooling Data Center Immersion Cooling Dry Coolers
2 Phase Submerged Immersed Server Cooling System For Datacenters
Product Specification
Payment Terms | T/T, Western Union | Supply Ability | 100 units/ month |
Delivery Time | 35~40days | Packaging Details | Stretch film +pallet for container loading |
Tube material | Cu | Fin material | Al |
Frame material | SUS 304/ G.I./ AL | Fan brand | ZIEHL-ABEGG Is OK |
Options A | Wet curtain or spray system | Options B | OEM is OK |
Application | Data center | Brand Name | Shenglin |
Model Number | SHSL-D2 Series | Certification | CE and RoHs |
Place of Origin | China | ||
High Light | Data Centers immersion cooling system ,OEM immersion cooling system ,liquid immersion cooling data center system |
Submeraged Coooling Two-Phase Immersion System For Data Centers
Advantages and disadvantages of dry cooler immersion cooling system
Pros: - High build quality by necessity - Up to 98% reduction in cooling power - Long life fluid (20 years) - High cooling capacity (4kw per liter) - Equipment is dry and clean when removed - Fairly simple plumbing - Excellent scaling | Cons:
- Not ideal at small scales - Control costs are the same for 250kW and 10kW - Controls are complex and expensive - Cannot use HDDs - Tanks must be stainless - Fluids leak easily so quality control must be tightly adhered to |
The submeraged cooling system diagram by dry cooler:
Shenglin and Shenglin partner can offer one-stop solution:
For bitcoin mining farm, if use immersion cooling system, Shenglin dry cooler is the most cost-effective way to remove heat and a necessary component of the immersion cooling system, We designed a full range of immersion optimized dry coolers. From 5kW single fan unit to the V-shaped 48-921kW dry coolers. Made in China, sized to your needs.
How to design a dry cooler?
Tell Shenglin the datas as following:
A. Required electrolyte inlet temperature?
B. Required electrolyte outlet temperature?
C. Electrolyte flow?
D. Ambient temperature?
E. Supply power(voltage-Hz-phase)
G. Any other requirements ?
Technical parameter of dry cooler
Dry cooler FLAT SERIES SINGLE ROW FANS
H*FS*91 H*FS*125 H*FS*180 | Van Dim mm | * | H*FS191 H*FS1125 H*FS1180 | H*FS291 H*FS2125 H*FS2180 | H*FS391 H*FS3125 H*FS3180 | H*FS491 H*FS4125 H*FS4180 | H*FS591 H*FS5125 H*FS5180 | H*FS691 H*FS6125 H*FS6180 | H*FS791 H*FS712 H*FS7180 | H*FS891 H*FS8125 H*FS8180 |
Rated Capacities (kW) Heat Exchange Surface (㎡) | ||||||||||
Fluid Coolers | 910 | D | 61kW-648kW 120㎡-2307㎡ (Water/Ta25℃/Tin40℃/Tout35℃) | |||||||
1250 | 138kW-1528kW 302㎡-4542㎡ (Water/Ta25℃/Tin40℃/Tout35℃) | |||||||||
1800 | 198kW-1920kW 363㎡-5084㎡ (Water/Ta25℃/Tin40℃/Tout35℃) | |||||||||
Freon Condensers | 910 | F | 73kW-764kW 120㎡-2307㎡ (R404A/Ta35℃/Tk50℃) | |||||||
1250 | 166kW-1549kW 302㎡-4842㎡ (R404A/Ta35℃/Tk50℃) | |||||||||
1800 | 230kW-1920kW 330㎡-5103㎡ (R404A/Ta35℃/Tk50℃) | |||||||||
Ammonia Condensers | 910 | A | 72kW-779kW 141㎡-2721㎡ (NH3/Ta35℃/Tk50℃ ) | |||||||
1250 | 181kW-1554kW 351㎡-5625㎡ (NH3/Ta35℃/Tk50℃ ) | |||||||||
1800 | 262kW-1986kW 421㎡-5907㎡ (NH3/Ta35℃/Tk50℃ ) | |||||||||
Gas Coolers | 910 | G | 49kW-862kW 96㎡-1824㎡ ( CO2/Tair32℃/Tin113℃/P94Bar/Tout34℃) | |||||||
Oil Coolers | 910 | O | 49kW-1041kW 120㎡-2307㎡ (OIL ISO VG 46/Ta35℃/Tin85℃/Tout60℃) | |||||||
1250 | 75kW-2021kW 302㎡-4842㎡ (OIL ISO VG 46/Ta35℃/Tin85℃/Tout60℃) | |||||||||
1800 | 92kW-2505kW 330㎡-5103㎡ (OIL ISO VG 46/Ta35℃/Tin85℃/Tout60℃) | |||||||||
Fan Model | 910 | EC | W3G910KU2503 (2.55kW) or FN091-ZIQ.GL.V5P1 (3.2kW) | |||||||
910 | AC | W6D910GB0101 (2.02kW) or FN091-SDS.6N.V7P2 (1.85kW) | ||||||||
1250 | EC | 160M2-8P-5.5kW/720RPM/1250_5-5_LP_39°_PPG_9W2L | ||||||||
1250 | AC | 160M2-8P-5.5kW/720RPM/1250_5-5_LP_39°_PPG_9W2L | ||||||||
No of Fans | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | ||
Overall Dimensions | 910 | Lenth-1 | 1980 | 3480 | 4980 | 6480 | 7980 | 9480 | 10980 | 12480 |
Lenth-2 | 2280 | 4080 | 5880 | 7680 | 9480 | 11280 | 13080 | 14880 | ||
Width | 1230 | |||||||||
Height | 1740 (Including 800Leg) | |||||||||
1250 | Lenth | 2600 | 4600 | 6600 | 8600 | 10600 | 12600 | 14600 | 16600 | |
Width | 2280 | |||||||||
Height | 1970 (Including 800Leg) | |||||||||
1800 | Lenth | 3000 | 5400 | 7800 | 10200 | 12600 | 15000 | 17400 | // | |
Width | 2280 | |||||||||
Height | 2170 (Including 1000Leg) |
Company Details
Business Type:
Manufacturer
Year Established:
2009
Employee Number:
>100
Ecer Certification:
Active Member
Introduction: Shanghai Shenglin is a professional manufacturer and sales of heat exchanger and air conditioning unit since 2009, located in Shanghai, China. Shanghai Shenglin was established in 2009, at the beginning only do HVAC international trading, then from 2012, we ... Introduction: Shanghai Shenglin is a professional manufacturer and sales of heat exchanger and air conditioning unit since 2009, located in Shanghai, China. Shanghai Shenglin was established in 2009, at the beginning only do HVAC international trading, then from 2012, we ...