China ISO14001 Standard Clean Room Air Conditioning System Air Handler
China ISO14001 Standard Clean Room Air Conditioning System Air Handler

  1. China ISO14001 Standard Clean Room Air Conditioning System Air Handler
  2. China ISO14001 Standard Clean Room Air Conditioning System Air Handler
  3. China ISO14001 Standard Clean Room Air Conditioning System Air Handler

ISO14001 Standard Clean Room Air Conditioning System Air Handler

  1. MOQ: 1
  2. Price: 5000~30000USD/unit
  3. Get Latest Price
Payment Terms T/T, Western Union
Supply Ability 100 Units Per Month
Delivery Time 35~40days
Packaging Details Plywood wooden box or pallet
Type Chilled water and modular type
Air cooled or water cooled Air cooled
Cooling coil Seamless copper tube and aluminum fin
Structure type Cabinet/ ceiling / vertical / horizontal type
Fan type Low noise centrifugal fan
Application hotels, theaters, shopping malls, office buildings
Air volume 2000~50000m³/h
Optional installation accessories Air valve, air duct or air grill
Advantage Drain tray applied thicken insulation material and no leakage.
Brand Name Shenglin
Model Number SL-ZKW Series
Certification CE
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, Western Union Supply Ability 100 Units Per Month
Delivery Time 35~40days Packaging Details Plywood wooden box or pallet
Type Chilled water and modular type Air cooled or water cooled Air cooled
Cooling coil Seamless copper tube and aluminum fin Structure type Cabinet/ ceiling / vertical / horizontal type
Fan type Low noise centrifugal fan Application hotels, theaters, shopping malls, office buildings
Air volume 2000~50000m³/h Optional installation accessories Air valve, air duct or air grill
Advantage Drain tray applied thicken insulation material and no leakage. Brand Name Shenglin
Model Number SL-ZKW Series Certification CE
Place of Origin China
High Light ISO14001 Clean Room Air Conditioning System2000m3 h Clean Room Air Conditioning System2000m3 h modular air handling unit
ISO14001 Standard Clean Room Air Conditioning System Air Handler
 
The combined air handling untis are modular designed ,each modular can be used independently and can also work together and company with fan coil units to add refresh air. Not only reduce operation costs and energy saving, but also optimize air quality and create a congnitive indoor space to meet the human health requirements.
 
Feature:
1, Complying with above China Standard, which is from ARI standard. ISO9001 and ISO14001 qualified.
2, Choose best materials, main components are from China top brand or imported.
3, The modular casing design, easy interchanging each other. easy install,easy transport,easy maintaince.
4, Unique no-cold-bridge design, improve the insulation and air tightness, total air leak rate ≤2.5%;
5, With dynamic balanced double inlet Centrifugal fan, with good air dynamic features, and accurate working, high efficiency, low vibration, low noise etc.
6, High efficient heat exchanger coil, ensure to provide the enough cooling capacity to the unit. And also high efficient breakwater panel is provided if required, water flow in coil ≤3×10-4kg/kg
7, Strong structure, good looking and permanent color.
8, Reasonable inside structure, with the suitable space for maintenance and cleaning.
9, Casing sheet: Provide double-skin construction constructing Sandwich type comprising 0.5mm thick galvanized internal and external skins and with 30mm thick polystyrene insulation of minimum 45kg/m3 density. Good airproof material is use between the casing and the frame to reduce the rate of the air leak.
 
Technical Data:
Chilled Water Air Handing Unit Spec. Table No. 2
Model SL-ZKW-()CW 300 350 400 450 500 550 600 700 800 1000
Air volume(m³/h) 30000 35000 40000 45000 50000 55000 60000 70000 80000 100000
Outlet air pressure(pa) 600 600 600 600 600 800 800 800 800 800
Supply fan capacity(kw) 18.5 18.5 22 22 30 30 37 37 45 55
Heating capacity(kw) 72 84 96 96 1201 120 150 180 180 210
Heating capacity(kg/h) 21 30 30 45 45 60 72 90 100 120
Filter type Pre-filter G4 (Med-filter F8 / Nano carbon filtration)
Power 3N-380V-50Hz
                         
Cooling 4 Rows Return Air Return air(kw) 179 210 245 277 306 340 375 440 504 590
water flow(m³/h) 28.2 36.2 42.1 47.6 53 58.2 64.6 76.1 86.8 101.3
water resistance(m³/h) 50 20 27 29 32 35 40 25 35 48
pipe diameter (DN) 80 65*2 65*2 80*2 80*2 80*2 80*2 100*2 100*2 100*2
4 Rows Fresh Air All fresh air(kw) 310 360 410 456 510 570 600 720 840 1020
water flow(m³/h) 55 62.5 72.2 78.4 87.6 98 103.1 123.7 144.3 175.3
water resistance(m³/h) 35 40 31 38 43 48 36 48 35 50
pipe diameter (DN) 80*2 80*2 100*2 100*2 100*2 100*2 80*3 80*3 100*3 100*3
6 Rows Return Air Return air(kw) 210 240 280 310 350 380 400 490 560 680
water flow(m³/h) 36 42.5 48.1 52.3 60 66 68.8 84.2 96.6 116.8
water resistance(m³/h) 25 0.3 35 40 49 26 34 39 32 40
pipe diameter (DN) 100 65*5 80*2 80*2 80*2 100*2 100*2 100*2 80*3 80*3
6 Rows Fresh Air All fresh air(kw) 420 456 532 590 665 720 760 930 1060 1290
water flow(m³/h) 72.5 78.4 91.4 101 114.3 123.7 130 160 182 221.6
water resistance(m³/h) 40 45 50 38 42 48 31 40 50 45
pipe diameter (DN) 100*2 100*2 100*2 80*3 80*3 80*3 100*3 100*3 100*3 125*3
8 Rows Return Air Return air(kw) 264 290 330 380 420 470 480 590 680 820
water flow(m³/h) 44.2 49.8 56.7 65.3 72.7 80.8 82.5 101.4 116.8 141
water resistance(m³/h) 29 35 40 31 36 42 45 30 40 42
pipe diameter (DN) 80*2 80*2 80*2 100*2 100*2 80*2 80*2 80*2 80*2 100*3
8 Rows Fresh Air All fresh air(kw) 500 550 630 720 800 890 910 1120 1290 1560
water flow(m³/h) 85 94.5 108.3 123.7 137.5 153 1564 192.5 221.7 268
water resistance(m³/h) 40 38 46 50 38 45 35 40 45 42
pipe diameter (DN) 100*2 80*3 80*3 80*3 100*3 100*3 100*3 125*3 125*3 100*4
 
Heating 2 Rows Return Air Return air(kw) 170 199 235 260 290 32 350 408 467 565
water flow(m³/h) 15 17 20 23 25 27.5 30 35 40 49
water resistance(m³/h) 11.5 16 14 21 22 15 20 26 32 24
pipe diameter (DN) 65 65 80 80 80 100 100 100    
2 Rows Fresh Air All fresh air(kw) 256 298 349 392 426 468 500 598 685 793
water flow(m³/h) 22 25 30 34 37 10.3 43 52 59 49
water resistance(m³/h) 20 24 25 14.5 14.9 19 22 17.8 15 16
pipe diameter (DN) 80 80 100 100 100 125 180 210 100*2  
4 Rows Return Air Return air(kw) 270 316 370 415 4.5 5.5 7.8 10 739 855
water flow(m³/h) 23.5 27.5 32 36 40 40 50 50 64.6 76.1
water resistance(m³/h) 16 13 12 110 140 200 250 320 10.5 20
pipe diameter (DN) 80 80 100 4.8 6.3 9 11 13.5 18.2  
4 Rows Fresh Air All fresh air(kw) 400 470 548 616 670 750 822 972 1095 1340
water flow(m³/h) 35 40 47 53 58 64.6 71 84 94 115
water resistance(m³/h) 20 17 24 27 27 29 31 35 42 25
pipe diameter (DN) 100 56 80 110 140 200 250 320 380  
 
Section
size
Standard Length(mm) 1960 2270 2270 2580 2580 3270 3270 3270 3270 3825
height(mm) 2040 2340 2340 2650 2650 2650 265 3340 3340 3340
 
Function
section
Mixing section Length(mm) 800 1000 1000 1000 1200 1200 1200 1200 1200 1200
Pre-filter section Length(mm) 100 100 100 100 100 100 100 100 100 100
Med-filter section Length(mm) 500 500 500 500 500 500 500 500 500 500
Cooling coil section Length(mm) 1000 1200 1200 1200 1200 1200 1200 1200 1200 1200
Heating section Length(mm) 100 500 500 500 500 600 600 600 600 600
Humidifying section Length(mm) 600 600 600 600 600 600 600 600 600 600
Fan section Length(mm) 1850 2000 2000 2000 2000 2200 2200 2300 2700 2700
Current balance section Length(mm) 700 800 500 800 800 800 800 800 800 800
Sound deadening section Length(mm) 1000 1200 1200 1200 1200 1200 1400 1400 1400 1400
Sterilization section Length(mm) 600 600 600 600 800 800 800 800 800 800
Air outlet section Length(mm) 800 1000 100 100 1200 1200 1500 1500 1500 1500
1. Cooling condition: supply and return water temp7/12℃,
indoor dry bulb/ wet bulb temp35/28℃, fresh air dry bulb/ wet bulb temp35/28℃

2. Heating condition conditions: supply and return water temp60/50℃,
indoor dry bulb/ wet bulb temp20/ -℃, fresh air dry bulb/ wet bulb temp7/6℃

3. The air volume, residual pressure and power in the table are standard parameters,
and are able to be customized

4. Heater, humidifier and heat recovery device are optional, which can be configured as spacific form according to customer's requirements

5. G4 filter is adopted as the unit standard, which can be configured as other form according to customer's requirements

6. The length and size are determined by the functional sections. Please consult us for details.

 

Application:

The units are widely used in the air system of many inductries like mechanical ,electronic, textile,medical,chemical,energy and foo inductries ,etc. the units are also ideal solution for restaurants, office buildings,hospitals,theaters,supermarkets and palaestra.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2009

  • Employee Number:

    >100

  • Ecer Certification:

    Active Member

Introduction:   Shanghai Shenglin is a professional manufacturer and sales of heat exchanger and air conditioning unit since 2009, located in Shanghai, China.   Shanghai Shenglin was established in 2009, at the beginning only do HVAC international trading, then from 2012, we ... Introduction:   Shanghai Shenglin is a professional manufacturer and sales of heat exchanger and air conditioning unit since 2009, located in Shanghai, China.   Shanghai Shenglin was established in 2009, at the beginning only do HVAC international trading, then from 2012, we ...

+ Read More

Get in touch with us

  • Reach Us
  • Shanghai Shenglin M&E Technology Co., Ltd.
  • Room B321, Building No.1, No. 619, Longchang Road, Yangpu District, Shanghai,China
  • https://www.waterchillerunits.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement