Payment Terms | T/T, Western Union |
Supply Ability | 1000 PCS/month |
Delivery Time | 15~20 days |
Packaging Details | Plywood box and with dust/moisture-proof film |
COP | 4 |
Compressor | Panasonic or Copeland brand |
Application | Appartment, School, Hospital, Villa |
Supply power | 380V/3PH/50Hz |
Refrigerant | R22/R417A/R404A/R407C/R410A |
Working ambient temperature | -15~45 ° C |
Warranty | 1 Year |
Installation | Freestanding |
Heating capacity range | 15~84kW |
Water outlet temp. | 55° C |
Max water outlet temp. | 60° C |
Remark | Can OEM |
Evaporator | Fin type heat exchanger |
Condenser | Coil type heat exchanger |
Brand Name | Shenglin |
Model Number | MD series |
Certification | CE |
Place of Origin | China |
View Detail Information
Explore similar products
3.2kw Swimming Pool Inverter Heat Pump , Low Temperature Heat Pump DN25
Dn25 15kw Air Source Heat Pumps For Swimming Pool Hotel Villa
Hot Water 52KW Rooftop Heat Pump High Temperature Rooftop Hvac Units
5HP 21kW Air Source Heat Pumps , Air Temp Heat Pump 5000L H
Product Specification
Payment Terms | T/T, Western Union | Supply Ability | 1000 PCS/month |
Delivery Time | 15~20 days | Packaging Details | Plywood box and with dust/moisture-proof film |
COP | 4 | Compressor | Panasonic or Copeland brand |
Application | Appartment, School, Hospital, Villa | Supply power | 380V/3PH/50Hz |
Refrigerant | R22/R417A/R404A/R407C/R410A | Working ambient temperature | -15~45 ° C |
Warranty | 1 Year | Installation | Freestanding |
Heating capacity range | 15~84kW | Water outlet temp. | 55° C |
Max water outlet temp. | 60° C | Remark | Can OEM |
Evaporator | Fin type heat exchanger | Condenser | Coil type heat exchanger |
Brand Name | Shenglin | Model Number | MD series |
Certification | CE | Place of Origin | China |
High Light | MD150D Air Source Heat Pump ,MD150D 84kW Air Source Heat Pump ,MD150D 60C Heat Pumps packaged |
Commercial Use Air Source Heat Pump
We are a professional heat exchanger, condenser, evaporator and heat pump manufacturer in China,which has more than 16 years experience in HVAC area. Our products have been exported to Europe, USA, Japan and Middle east etc.
Technical paramater:
Air source heat pump | MODEL | Unit | MD40D | ||
Average heating input power | KW | 3.78 | |||
Rated heating capacity | KW | 15 | |||
Hot water supply | L/h | 350 | |||
Rated heating input current | A | 9 | |||
Max outlet water temp | ℃ | 60 | |||
Power | V/Hz | 380V/50 | |||
Noise | Db(a) | 55 | |||
Dimension | W*D*H | mm | 1120*490*1270 | ||
Packing size | W*D*H | mm | 1200*520*1425 | ||
Unit weight | KG | 160 | |||
Working air temp range | (-15℃)—45℃ | ||||
compressor | Type | Copeland | |||
Air source heat exchanger | Type | Finned heat exchange | |||
Fan Type | axial flow fan | ||||
Hot water side heat exchange | Type | Coil heat exchanger | |||
Water flow | L/H | 4000L/h | |||
Water pressure down | Kpa | 55 | |||
Pipe size | DN | 25 | |||
Air source heat pump | MODEL | Unit | MD50D | ||
Average heating input power | KW | 4.6 | |||
Rated heating capacity | KW | 18.6 | |||
Hot water supply | L/h | 400 | |||
Rated heating input current | A | 9 | |||
Max outlet water temp | C | 60 | |||
Power | V/Hz | 380V/50 | |||
Noise | Db(a) | 55 | |||
Dimension | W*D*H | mm | 1120*490*1270 | ||
Packing size | W*D*H | mm | 1200*520*1425 | ||
Unit weight | KG | 170 | |||
Working air temp range | (-15℃)—45℃ | ||||
compressor | Type | Copeland | |||
Air source heat exchanger | Type | Finned heat exchange | |||
Fan Type | axial flow fan | ||||
Hot water side heat exchange | Type | Coil heat exchanger | |||
Water flow | L/H | 5000L/h | |||
Water pressure down | Kpa | 45 | |||
Pipe size | DN | 25 | |||
Article | Parameter | ||||
Air source heat pump | MODEL | Unit | MD60D | ||
Average heating input power | KW | 5.2 | |||
Rated heating capacity | KW | 21 | |||
Hot water supply | L/h | 500 | |||
Rated heating input current | A | 12 | |||
Max outlet water temp | ℃ | 60 | |||
Power | V/Hz | 380/50 | |||
Noise | Db(a) | 60 | |||
Dimension | W*D*H | mm | 1120*490*1270 | ||
Packing size | W*D*H | mm | 1200*520*1425 | ||
Unit weight | KG | 180 | |||
Working air temp range | (-15℃)—45℃ | ||||
compressor | Type | Copeland | |||
Air source heat exchanger | Type | Finned heat exchange | |||
Fan Type | axial flow fan | ||||
Hot water side heat exchange | Type | Coil heat exchanger | |||
Water flow | L/H | 6000L/h | |||
Water pressure down | Kpa | 48 | |||
Pipe size | DN | 25 | |||
Air source heat pump | MODEL | Unit | MD100D | ||
Average heating input power | KW | 9.2 | |||
Rated heating capacity | KW | 36 | |||
Hot water supply | L/h | 800 | |||
Rated heating input current | A | 18 | |||
Max outlet water temp | ℃ | 60 | |||
Power | V/Hz | 380V/50 | |||
Noise | Db(a) | 60 | |||
Dimension | W*D*H | mm | 1450×760×1060 | ||
Packing size | W*D*H | mm | 1520*800*1230 | ||
Unit weight | KG | 310 | |||
Working air temp range | (-15℃)—45℃ | ||||
compressor | Type | Copeland | |||
Air source heat exchanger | Type | Finned heat exchange | |||
Fan Type | axial flow fan | ||||
Hot water side heat exchange | Type | Coil heat exchanger | |||
Water flow | L/H | 10000L/h | |||
Water pressure down | Kpa | 54 | |||
Pipe size | DN | 32 | |||
Air source heat pump | MODEL | Unit | MD150D | ||
Average heating input power | KW | 11 | |||
Rated heating capacity | KW | 42 | |||
Hot water supply | L/h | 1000 | |||
Rated heating input current | A | 24 | |||
Max outlet water temp | ℃ | 60 | |||
Power | V/Hz | 380V/50 | |||
Noise | Db(a) | 60 | |||
Dimension | W*D*H | mm | 1450×760×1060 | ||
Packing size | W*D*H | mm | 1520*800*1230 | ||
Unit weight | KG | 340 | |||
Working air temp range | (-15℃)—45℃ | ||||
compressor | Type | Copeland | |||
Air source heat exchanger | Type | Finned heat exchange | |||
Fan Type | axial flow fan | ||||
Hot water side heat exchange | Type | Coil heat exchanger | |||
Water flow | L/H | 12000L/h | |||
Water pressure down | Kpa | 54 | |||
Pipe size | DN | 32 | |||
Article | Parameter | ||||
Air source heat pump | MODEL | Unit | MD200D | ||
Average heating input power | KW | 19 | |||
Rated heating capacity | KW | 72 | |||
Hot water supply | L/h | 1600 | |||
Rated heating input current | A | 35 | |||
Max outlet water temp | ℃ | 60 | |||
Power | V/Hz | 380V/50 | |||
Noise | Db(a) | 70 | |||
Dimension | W*D*H | mm | 2040×1100×2000 | ||
Packing size | W*D*H | mm | 2080×1150×2130 | ||
Unit weight | KG | 650 | |||
Working air temp range | (-15℃)—45℃ | ||||
compressor | Type | Copeland | |||
Air source heat exchanger | Type | Finned heat exchange | |||
Fan Type | axial flow fan | ||||
Hot water side heat exchange | Type | Coil heat exchanger | |||
Water flow | L/H | 20000L/h | |||
Water pressure down | Kpa | 60 | |||
Pipe size | DN | 50 | |||
Air source heat pump | MODEL | Unit | MD300D | ||
Average heating input power | KW | 22 | |||
Rated heating capacity | KW | 84 | |||
Hot water supply | L/h | 2000 | |||
Rated heating input current | A | 40 | |||
Max outlet water temp | ℃ | 60 | |||
Power | V/Hz | 380V/50 | |||
Noise | Db(a) | 70 | |||
Dimension | W*D*H | mm | 2040×1100×2000 | ||
Packing size | W*D*H | mm | 2080×1150×2130 | ||
Unit weight | KG | 750 | |||
Working air temp range | (-15℃)—45℃ | ||||
compressor | Type | Copeland | |||
Air source heat exchanger | Type | Finned heat exchange | |||
Fan Type | axial flow fan | ||||
Hot water side heat exchange | Type | Coil heat exchanger | |||
Water flow | L/H | 25000L/h | |||
Water pressure down | Kpa | 60 | |||
Pipe size | DN | 50 |
Packing:
![]() | ![]() |
Simple installation diagram for air source:
Company Details
Business Type:
Manufacturer
Year Established:
2009
Employee Number:
>100
Ecer Certification:
Active Member
Introduction: Shanghai Shenglin is a professional manufacturer and sales of heat exchanger and air conditioning unit since 2009, located in Shanghai, China. Shanghai Shenglin was established in 2009, at the beginning only do HVAC international trading, then from 2012, we ... Introduction: Shanghai Shenglin is a professional manufacturer and sales of heat exchanger and air conditioning unit since 2009, located in Shanghai, China. Shanghai Shenglin was established in 2009, at the beginning only do HVAC international trading, then from 2012, we ...
Get in touch with us
Leave a Message, we will call you back quickly!