Payment Terms | T/T, Western Union |
Supply Ability | 100 units per month |
Delivery Time | 30~35days |
Packaging Details | Stretch film and Pallet |
Tube material | Copper tubes |
Fin material | Hydrophilic aluminum foil or epoxy resin aluminum foil |
Frame material | Galvanized steel plate or stainless steel |
Power supply | 380V/3P/50Hz or 418V/3P/60Hz |
Fan brand | Usually Chinese brand Kemao |
Product category | Adiabatic Dry Coolers |
Cooling way | Crypto Immersion cooling |
Advantage | Energy saving and save floor space |
Media | Electrocool dielectric coolants |
Brand Name | Shenglin |
Model Number | SHSL-D1 Series |
Certification | CE |
Place of Origin | China |
View Detail Information
Explore similar products
Wet-Dry Coolers Direct Water Spray Two Phase Liquid Bitcoin Cooling System
Submerging Bitcoin Miners Two Phase Immersion Cooling Dry Coolers
Flat Type High Heat Transfer Efficiency Immersion Bitcoin Cooling System
Ziehl-Abegg Fan Dry Fluid Cooler Table Type Structure For Immersion Cooling
Product Specification
Payment Terms | T/T, Western Union | Supply Ability | 100 units per month |
Delivery Time | 30~35days | Packaging Details | Stretch film and Pallet |
Tube material | Copper tubes | Fin material | Hydrophilic aluminum foil or epoxy resin aluminum foil |
Frame material | Galvanized steel plate or stainless steel | Power supply | 380V/3P/50Hz or 418V/3P/60Hz |
Fan brand | Usually Chinese brand Kemao | Product category | Adiabatic Dry Coolers |
Cooling way | Crypto Immersion cooling | Advantage | Energy saving and save floor space |
Media | Electrocool dielectric coolants | Brand Name | Shenglin |
Model Number | SHSL-D1 Series | Certification | CE |
Place of Origin | China | ||
High Light | Dry Cooler BTC Cooling System ,Adiabatic BTC Cooling System ,Adiabatic BTC Cooling equipment |
What's Immersion Cooling?
Also known as liquid submersion cooling. It is the practice of submerging computer components (or full servers) in a thermally, but not electrically, conductive liquid (dielectric coolant) allowing higher heat transfer performance than air and many other benefits.
Why many large data centers have already moved or are considering the move to immersion cooling?
1. Up to 25% increase in power efficiency
2. Up to 80% cost reduction
3. Up to 60% hashrate increase
4. 50%+ equipment lifespan.
What's two-phase liquid cooling?
The cooling liquid undergoes a phase change in the process of circulating heat dissipation. The cooling liquid takes away the heat from the server and then undergoes a phase change gasification. The gaseous cooling liquid is condensed by the condenser and becomes liquid again and returns to the liquid cooling tank; the cooling liquid can use 3M electronics The boiling point of the coolant FC-72 and FC-72 is above 50℃. In this case, the temperature of the water in the condensing coil does not need to be too low. The use of a dry cooler can meet the heat exchange requirements and take away the heat. The two-phase liquid cooling has a high heat transfer efficiency due to the phase change of the electronic cooling liquid. The disadvantage is that during this phase change, the electronic fluorinated liquid will escape during the vaporization process, so there is a certain degree of tightness of the container. However, it should not be too sealed to prevent the cooling system from being interrupted and the cylinder explosion event, so certain safety facilities need to be set up.
For bitcoin mining farm, if use immersion cooling system, our dry cooler is the most cost-effective way to remove heat and a necessary component of the immersion cooling system, We designed a full range of immersion optimized dry coolers. From 5kW single fan unit to the V-shaped 48-921kW dry coolers. Made in China, sized to your needs.
Also, we have whole immersion cooling system partner in USA and European, they can also offer the whole system proposal for you.
Features of adiabatic dry coolers
1. Material options:
A. Heavy-gauge hot-dip galvanized steel is used for unit steel panels and structural elements featuring a zinc aluminium coating.
2. Heat transfer media:
A. The dry cooler is constructed of staggered and seamless copper tubes (15,9 or 12,7 diameter) with aluminium, rippled and corrugated fins (0,14 or 0,17 thickness).
B. 2.5 mm fin spacing for optimal air turbulence
C. Thick and seamless copper headers and threaded steel connections
D. Pressure tested at 30 bar
E. Try our options for aggressive environments: special pre-coated anti-corrosion aluminium fins or copper fins (0,2 mm thickness).
3. Air movement system:
A. Axial fan with exceptionally compact direct drive short integrated motor and fan guard.
B. The fan features an impeller and motor and is balanced as a complete unit using dynamic single plane balancing. Balance grade is G6.3.
C. Fan and motor totally maintenance free.
D. Bearings seals and motor encapsulation for long service life.
Our USA partner can offer the cryptocurrency miner cooling system solution, like this way:
Technical parameter
Dry cooler D1 series parameter (fin space 2.1mm)
Type | D1-005- 1x350 | D1-006- 1x350 | D1-007- 1x350 | D1-009- 1x450 | D1-011- 1x450 | D1-013- 1x450 | D1-014- 1x500 | D1-017- 1x500 | D1-020- 1x500 | ||||||
Capacity | Water | 35℃ outdoor temp. | Inlet | 45℃ | △ | KW | 4.89 | 5.9 | 6.83 | 9.39 | 10.99 | 13.33 | 14.32 | 17.01 | 19.8 |
outlet | 40℃ | Y | |||||||||||||
20% Glycol | Inlet | 45℃ | △ | 4.72 | 5.69 | 6.69 | 8.9 | 10.61 | 13.05 | 13.91 | 16.11 | 19.29 | |||
outlet | 40℃ | Y | |||||||||||||
Medium | Water flow | M3/h | 0.85 | 1.03 | 1.2 | 1.63 | 1.91 | 2.3 | 2.5 | 3 | 3.5 | ||||
Pressure drop | kPa | 36 | 31 | 58 | 25 | 40 | 80 | 50 | 60 | 40 | |||||
Air flow | △ | M3/h | 2828 | 2712 | 2492 | 6199 | 5827 | 5225 | 8469 | 8168 | 7601 | ||||
Y | |||||||||||||||
Fan motor | Phase | 1 | 1 | 1 | 3 | 3 | 3 | 3 | 3 | 3 | |||||
△ | W | 140 | 140 | 140 | 540 | 540 | 540 | 830 | 830 | 830 | |||||
Y | |||||||||||||||
△ | A | 0.6 | 0.6 | 0.6 | 1.1 | 1.1 | 1.1 | 1.45 | 1.45 | 1.45 | |||||
Y | |||||||||||||||
Fan | No X φ | 1x1x350 | 1x1x350 | 1x1x350 | 1x1x450 | 1x1x450 | 1x1x450 | 1x1x500 | 1x1x500 | 1x1x500 | |||||
Sound pressure level | △ | dB(A) | 31 | 31 | 31 | 43 | 43 | 43 | 49 | 49 | 49 | ||||
Y | 10m | ||||||||||||||
Dimension | L | mm | 870 | 870 | 870 | 1020 | 1020 | 1020 | 1220 | 1220 | 1220 | ||||
W | mm | 525 | 525 | 525 | 625 | 625 | 625 | 825 | 825 | 825 | |||||
H | mm | 797 | 797 | 797 | 820 | 820 | 820 | 870 | 870 | 870 | |||||
A | mm | 690 | 690 | 690 | 840 | 840 | 840 | 1040 | 1040 | 1040 | |||||
B | mm | -- | -- | -- | -- | -- | -- | -- | -- | -- | |||||
C | mm | -- | -- | -- | -- | -- | -- | -- | -- | -- | |||||
D | mm | 490 | 490 | 490 | 490 | 490 | 490 | 490 | 490 | 490 | |||||
Inlet φ | mm | 3/4” | 3/4” | 3/4” | 1” | 1” | 1” | 1-1/4” | 1-1/4” | 1-1/4” | |||||
Inlet φ | mm | 3/4” | 3/4” | 3/4” | 1” | 1” | 1” | 1-1/4” | 1-1/4” | 1-1/4” | |||||
Product weight(empty) | kg | 38 | 42 | 48 | 55 | 60 | 67 | 75 | 82 | 91 |
Note: Standard SHSL-D1 dry cooler is vertical air discharge, for horizontal air discharge please add “H” in nomenclature, for excmple:SHSL-D1-005H-1X350
Company Details
Business Type:
Manufacturer
Year Established:
2009
Employee Number:
>100
Ecer Certification:
Active Member
Introduction: Shanghai Shenglin is a professional manufacturer and sales of heat exchanger and air conditioning unit since 2009, located in Shanghai, China. Shanghai Shenglin was established in 2009, at the beginning only do HVAC international trading, then from 2012, we ... Introduction: Shanghai Shenglin is a professional manufacturer and sales of heat exchanger and air conditioning unit since 2009, located in Shanghai, China. Shanghai Shenglin was established in 2009, at the beginning only do HVAC international trading, then from 2012, we ...