China factories

China factory - Jufu Water Technology Co., Ltd

Jufu Water Technology Co., Ltd

  • China ,Shaanxi
  • Active Member

Leave a Message

we will call you back quickly!

Submit Requirement
China Pure Water Drinking Water RO System One Stage RO FRP 500LPH
China Pure Water Drinking Water RO System One Stage RO FRP 500LPH

  1. China Pure Water Drinking Water RO System One Stage RO FRP 500LPH

Pure Water Drinking Water RO System One Stage RO FRP 500LPH

  1. MOQ: 1 unit
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability
Delivery Time 2-4 weeks
Packaging Details Export standard wooden box (like plywood), no need to fumigate, really suitable for shipping.
Host size 800x600x1600mm (can be customized)
Warranty 1 Year
Producing capacity 500L/h
Power 1.5KW
Power supply 220V/380V/460V-50Hz can be customized
Recovery rate 50%
RO frame SUS304
Raw water pump CNP/NYP/GRUNDFOS (optional)
Tank material SS/FRP (optional)
Pipe material U-PVC/Stainless steel (optional)
Brand Name Jufu
Model Number JFRO-500L
Certification ISO9001
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram Supply Ability
Delivery Time 2-4 weeks Packaging Details Export standard wooden box (like plywood), no need to fumigate, really suitable for shipping.
Host size 800x600x1600mm (can be customized) Warranty 1 Year
Producing capacity 500L/h Power 1.5KW
Power supply 220V/380V/460V-50Hz can be customized Recovery rate 50%
RO frame SUS304 Raw water pump CNP/NYP/GRUNDFOS (optional)
Tank material SS/FRP (optional) Pipe material U-PVC/Stainless steel (optional)
Brand Name Jufu Model Number JFRO-500L
Certification ISO9001 Place of Origin China
High Light Pure Water Drinking Water RO System500LPH ro drinking water systemsOne Stage Drinking Water RO System

Drinking Water RO System one-Stage RO FRP 500LPH For Pure water
 
Drinking water RO system mechanism model:
1. Preferential adsorption capillary pore model: No pores were found under the dry-state membrane electron microscope of the weak point. Wet film specimens are not samples for electron microscopy.
2. Dissolution-Diffusion Model: No pores are considered.
3. Dry closed and wet open model: In the 1980s and 1990s, it was the most appropriate modern reverse osmosis mechanism model that explained the 1 and 2 models. Both the "dry closed and wet open" reverse osmosis model unifies the two most classic reverse osmosis mechanism models, the pore model and the dissolution and diffusion model.
When the film is dry, the film pores are shrunk and compacted, the pores are closed, and the dry film prepared in a dry state for microscopic examination cannot be seen under the electron microscope;
When the membrane is wet, the membrane material swells, the pores of the membrane are swelled by the solvent, and the pores open. The combination is the "dry closed wet open" desalination model.

 
Technical specifications of Drinking Water RO System
 

Model

JFRO-500L

Host Size

800x600x1600mm (can be customized)

Power

1.5KW

Power Supply

220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized

Operating Pressure

0.8-1.2MPa

Recovery Rate

50%

Designed Water Inlet

1000L/h

Outlet Flow

500L/h

Desalination Rate

≥99.5%

RO Frame

SUS304

Membrane Size

4040

Membrane Elements

DOW /Hydranautics/Troy/ Vontron (Optional)

Number of Membranes

2

Raw Water Pump

CNP/NYP/GRUNDFOS (Optional)

Raw Water Pump

CNP/NYP/GRUNDFOS (Optional)

Tank Material

SS/FRP (Optional)

Control Valve

Manual/Automatic

Control Valve Brand

FLECK/RUNXIN

Membrane Housing

SS/FRP (Optional)

Pipe Material

U-PVC, Stainless steel (Optional)

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Drinking water RO system preprocessing requirements:
1. The reverse osmosis pretreatment must be able to remove most of the impurities in the raw water to meet the water inlet requirements;
2. Reverse osmosis pretreatment must consider changes in water quality to prevent fluctuations in raw water quality from affecting the stable operation of the entire system;
3. The reverse osmosis pretreatment process must be able to operate efficiently and stably, while simplifying the process as much as possible to reduce investment and operating costs;
 

Process flow of Drinking Water RO System
Source water tank → source water booster pump → multi-media filter → active carbon filter → resin softening device → precision filter → first RO reverse osmosis pure water system → second RO reverse osmosis pure water system → water-gas mixer → ozone sterilizer → stainless steel pure water tank → automatic filling line
 

 
Drinking water RO system membrane advantages:
1. Cross-flow operation process, strong anti-pollution ability, good regeneration performance and long service life.
2. The separation precision is high, and the permeated liquid is clear and transparent, which greatly reduces the load of the subsequent refining process.
3. Achieve high multiple concentration of fermentation broth and improve product yield.
4. While improving the product yield, the bacteria in the fermentation broth can be recovered, bringing more profit points and environmental protection benefits to the enterprise.
5. There is no need for filter aids in the treatment process, and there is no retention of active ingredients in the fermentation broth.
6. Realize clean production, reduce the amount of acid, alkali and water washing, and greatly improve the biodegradability of wastewater.
7. There is no phase change in the system operation, low energy consumption and lower production cost.

 
 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

FAQ:
 
1, What are the inlet water quality requirements for ro water treatment system membrane components?

 
Items

NTU SDI Residual chlorine(mg/L) Fe2+(mg/L) TOC(mg/L)
Limits ≤1 ≤5   ≤4 ≤3

 
 
 

 
 
 
2. What is the material of ro water treatment system membrane?
 
Acetate membrane (CA) : mainly because of its resistance to chlorine, so it is still durable. But its suitable pH range is small, easy hydrolysis
 
Aromatic polyamide membrane (PA) : water almost can not have chlorine, only through a variety of pretreatment chlorine.

 
 
3. RO water treatment system configuration:
 
First-stage multi-stage process: if the recovery rate is not achieved in the first stage (50-65% in the first stage and 65-75% in the second stage), the multi-stage tandem filtration can be used. The effective cross-sectional area of each segment decreases. 2:2 and 2:3 and 4:2:1
 
Multi-stage process: when the first stage process cannot meet the effluent quality requirements (the first stage is generally ≤20μs/cm), the product water of the first stage process is sent to another reverse osmosis unit.
 
The arrangement of membrane components can be divided into series and parallel.

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    2008

  • Total Annual:

    1-10 Mln

  • Employee Number:

    20~100

  • Ecer Certification:

    Active Member

Jufu Water is a Hi-tech enterprise which specialized in integrating Research & Development, Manufacturing, Sales, Engineering installation and Consulting on water treatment and water purification equipment and technologies.   Jufu has strong power on know-how solution providing. The w... Jufu Water is a Hi-tech enterprise which specialized in integrating Research & Development, Manufacturing, Sales, Engineering installation and Consulting on water treatment and water purification equipment and technologies.   Jufu has strong power on know-how solution providing. The w...

+ Read More

Get in touch with us

  • Reach Us
  • Jufu Water Technology Co., Ltd
  • 15F, Block B, FRD International Wealth Center, Fengcheng 12th Road, Weiyang District, Xi’an,Shaanxi, China 710018
  • https://www.rowatertreatmentsystems.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement