Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Delivery Time | 2-4 weeks |
Packaging Details | Export standard wooden box (like plywood), no need to fumigate, really suitable for shipping. |
Type | Reverse Osmosis |
Capacity | 1000L/H |
Warranty | 12 Months |
After-sales service provided | Online support |
Product name | RO water treatment system |
Function | Wate Purification |
Voltage | 110V/220V/380V can be customized |
Membrane Size | 4040 |
Brand Name | Jufu |
Model Number | JFRO-1000L |
Certification | ISO9001 |
Place of Origin | China |
View Detail Information
Explore similar products
500LPH Reverse Osmosis Filtration System
80TPH RO Water Treatment System FRP Pure Water Reverse Osmosis System
Pharmaceutical RO Water Treatment Plant Purified Water Machine 1000LPH
Water Reuse RO Water Treatment System 50TPH Water Filter System
Product Specification
Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram | Delivery Time | 2-4 weeks |
Packaging Details | Export standard wooden box (like plywood), no need to fumigate, really suitable for shipping. | Type | Reverse Osmosis |
Capacity | 1000L/H | Warranty | 12 Months |
After-sales service provided | Online support | Product name | RO water treatment system |
Function | Wate Purification | Voltage | 110V/220V/380V can be customized |
Membrane Size | 4040 | Brand Name | Jufu |
Model Number | JFRO-1000L | Certification | ISO9001 |
Place of Origin | China | ||
High Light | Pure Water Purifying Machine 1000L/H ,Double Stage Water Reverse Osmosis System ,Reverse Osmosis Water Purifying Machine 110V |
Water Purifying Machine Double Stage Reverse Osmosis Pure Water Equipment
Reverse osmosis technology process
RO membrane itself is sensitive to the pH, temperature and specific chemicals of the influent. The water quality of the influent strictly requires the pH value range of 4~10, temperature <40℃, silt density index SDI<5, free chlorine <0.1mg·L-1, turbidity <1, iron content <0.1mg·L-1, etc. In order to meet the requirements of RO membrane water, raw water before entering the RO membrane system must first preprocessing (sedimentation, coagulation and microfiltration, ultrafiltration, activated carbon absorption, pH adjustment, etc.), then the pump pressure into the membrane module, the pressure under the action of raw water as water production through the RO membrane, and inorganic salts, organic matter and particle by RO membrane intercept on the other side of the membrane to form thick liquid. The concentrated solution can be recycled or reprocessed according to the requirements of the specific process. RO can be used with ultrafiltration, nanofiltration and other membrane devices to form an integrated membrane device.
Working Principle of Reverse Osmosis Water Treatment System:
When a pressure greater than osmotic pressure is applied on the saltwater side of the membrane, the flow of water is reversed and the water in the saltwater flows into the fresh side, a phenomenon called reverse osmosis.
Technical Specifications of Reverse Osmosis Water Treatment System:
6m³/h Reverse Osmosis System | |
Model | JFRO-6000L |
Host Size | 3000x800x1600mm (can be customized) |
Power | 5.5KW |
Power Supply | 220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized |
Operating Pressure | 0.8-1.2MPa |
Recovery Rate | 60% |
Designed Water Inlet | 10000L/h |
Outlet Flow | 6000L/h |
Desalination Rate | ≥99.5% |
RO Frame | SUS304 |
Membrane Size | 8040 |
Membrane Elements | DOW /Hydranautics/Troy/ Vontron (Optional) |
Number of Membranes | 6 |
Raw Water Pump | CNP/NYP/GRUNDFOS (Optional) |
High Pressure Pump | CNP/NYP/GRUNDFOS (Optional) |
Tank Material | SS/FRP(Optional) |
Control Valve | Manual/Automatic |
Control Valve Brand | FLECK/RUNXIN |
Membrane Housing | FRP |
Number of Membrane housing | 3 |
Pipe Material | U-PVC/ Stainless steel (Optional) |
Process flow of reverse osmosis water treatment system:
Raw water → original water tank → original water pump → multi-media filter (quartz sand filter)→ activated carbon filter → soft water processor → precision filter → high pressure pump → first stage reverse osmosis (RO) device → pure water tank → high pressure pump → second stage reverse osmosis → ultraviolet sterilization device → water point
Application field of reverse osmosis system:
1, the electronic industry water integrated circuit, silicon chip, display tube, electrode foil and other electronic components flushing water.
2, pharmaceutical industry water transfusion, injection, tablet, biochemical products, equipment cleaning, etc.
3, chemical industry process water chemical circulating water, chemical product manufacturing, fertilizer, etc.
4, the power industry boiler supply water thermal power boilers, factories and mines in low pressure boiler power system.
5, food industry water application of purified water, drinks, beer, liquor, health products, etc.
6, seawater, brackish water desalination islands, ships, offshore drilling platforms, brackish water areas.
7, drinking water real estate, community, enterprises and institutions, etc.
8, other process water automobile, home appliance product coating, coated glass, cosmetics, fine chemicals, printing and dyeing, etc.
FAQ:
1, What are the inlet water quality requirements for ro water treatment system membrane components?
| NTU | SDI | Residual chlorine(mg/L) | Fe2+(mg/L) | TOC(mg/L) |
Limits | ≤1 | ≤5 | ≤4 | ≤3 |
2. What is the material of ro water treatment system membrane?
Acetate membrane (CA) : mainly because of its resistance to chlorine, so it is still durable. But its suitable pH range is small, easy hydrolysis
Aromatic polyamide membrane (PA) : water almost can not have chlorine, only through a variety of pretreatment chlorine.
3. RO water treatment system configuration:
First-stage multi-stage process: if the recovery rate is not achieved in the first stage (50-65% in the first stage and 65-75% in the second stage), the multi-stage tandem filtration can be used. The effective cross-sectional area of each segment decreases. 2:2 and 2:3 and 4:2:1
Multi-stage process: when the first stage process cannot meet the effluent quality requirements (the first stage is generally ≤20μs/cm), the product water of the first stage process is sent to another reverse osmosis unit.
The arrangement of membrane components can be divided into series and parallel.
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2008
Total Annual:
1-10 Mln
Employee Number:
20~100
Ecer Certification:
Active Member
Jufu Water is a Hi-tech enterprise which specialized in integrating Research & Development, Manufacturing, Sales, Engineering installation and Consulting on water treatment and water purification equipment and technologies. Jufu has strong power on know-how solution providing. The w... Jufu Water is a Hi-tech enterprise which specialized in integrating Research & Development, Manufacturing, Sales, Engineering installation and Consulting on water treatment and water purification equipment and technologies. Jufu has strong power on know-how solution providing. The w...
Get in touch with us
Leave a Message, we will call you back quickly!