China SIL 2 P+F Sensors Switch Amplifier KFD2-SR2-Ex1.W
China SIL 2 P+F Sensors Switch Amplifier KFD2-SR2-Ex1.W

  1. China SIL 2 P+F Sensors Switch Amplifier KFD2-SR2-Ex1.W
  2. China SIL 2 P+F Sensors Switch Amplifier KFD2-SR2-Ex1.W
  3. China SIL 2 P+F Sensors Switch Amplifier KFD2-SR2-Ex1.W

SIL 2 P+F Sensors Switch Amplifier KFD2-SR2-Ex1.W

  1. MOQ: 1pc
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms T/T
Supply Ability 100pcs per month
Delivery Time on request
Packaging Details standard carton packing
Signal type Digital Input
Safety Integrity Level (SIL) SIL 2
Systematic capability (SC) SC 3
Connection Power Rail or terminals 14+, 15-
Rated voltage 19 ... 30 V DC
Ripple ≤ 10 %
Rated current ≤ 35 mA
Power dissipation ≤ 0.7 W
Brand Name P+F
Model Number KFD2-SR2-Ex1.W
Certification CE
Place of Origin Germany

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Supply Ability 100pcs per month
Delivery Time on request Packaging Details standard carton packing
Signal type Digital Input Safety Integrity Level (SIL) SIL 2
Systematic capability (SC) SC 3 Connection Power Rail or terminals 14+, 15-
Rated voltage 19 ... 30 V DC Ripple ≤ 10 %
Rated current ≤ 35 mA Power dissipation ≤ 0.7 W
Brand Name P+F Model Number KFD2-SR2-Ex1.W
Certification CE Place of Origin Germany
High Light P+F Sensors Switch AmplifierSIL 2 P+F SensorsKFD2-SR2-Ex1.W

Switch Amplifier KFD2-SR2-Ex1.W

 

1-channel isolated barrier
24 V DC supply (Power Rail)
Dry contact or NAMUR inputs
Relay contact output
Line fault detection (LFD)
Reversible mode of operation
Up to SIL 2 (SC 3) acc. to IEC/EN 61508

 

General specifications

Signal type Digital Input

 
Functional safety related parameters

Safety Integrity Level (SIL) SIL 2

Systematic capability (SC) SC 3

 
Supply

Connection Power Rail or terminals 14+, 15-

Rated voltage 19 ... 30 V DC

Ripple ≤ 10 %

Rated current ≤ 35 mA

Power dissipation ≤ 0.7 W

Power consumption ≤ 0.7 W

 
Input

Connection side field side

Connection terminals 1+, 2+, 3-

Rated values acc. to EN 60947-5-6 (NAMUR)

Open circuit voltage/short-circuit current approx. 8 V DC / approx. 8 mA

Switching point/switching hysteresis 1.2 ... 2.1 mA / approx. 0.2 mA

Line fault detection breakage I ≤ 0.1 mA , short-circuit I > 6 mA

Pulse/Pause ratio min. 20 ms / min. 20 ms

 
Output

Connection side control side

Connection terminals 7, 8, 9

Output signal ; relay

Contact loading 250 V AC/2 A/cos φ > 0.75; 126.5 V AC/4 A/cos φ > 0.75; 40 V DC/2 A resistive load

Minimum switch current 2 mA / 24 V DC

Energized/De-energized delay approx. 20 ms / approx. 20 ms

Mechanical life 107 switching cycles

Collective error message Power Rail

 
Transfer characteristics

Switching frequency < 10 Hz

 
Galvanic isolation

Input/Output reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

Input/power supply reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

Output/power supply reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

 
Indicators/settings

Display elements LEDs

Control elements DIP switch

Configuration via DIP switches

Labeling space for labeling at the front

 
Directive conformity

Electromagnetic compatibility

Directive 2014/30/EU EN 61326-1:2013 (industrial locations)

Low voltage

Directive 2014/35/EU EN 61010-1:2010+A1:2019+A1:2019/AC:2019

 
Conformity

Electromagnetic compatibility NE 21:2017 , EN 61326-3-1:2017 , EN IEC 61326-3-2:2018

Degree of protection IEC 60529:1989+A1:1999+A2:2013

Functional safety IEC/EN 61508:2010

Input EN 60947-5-6:2000

 
Ambient conditions

Ambient temperature -40 ... 70 °C (-40 ... 158 °F)

 
Mechanical specifications

Degree of protection IP20

Connection screw terminals

Mass approx. 150 g

Dimensions 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) (W x H x D) , housing type B2

Height 119 mm

Width 20 mm

Depth 115 mm

Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001

 
Data for application in connection with hazardous areas

EU-type examination certificate PTB 00 ATEX 2080

Marking Ex-Hexagon II (1)G [Ex ia Ga] IIC

Ex-Hexagon II (1)D [Ex ia Da] IIIC

Ex-Hexagon I (M1) [Ex ia Ma] I

Input Ex ia

Voltage 10.5 V

Current 13 mA

Power 34 mW (linear characteristic)

Supply

Maximum safe voltage 253 V AC / 125 V DC (Attention! Um is no rated voltage.)

Output

Maximum safe voltage 253 V AC (Attention! The rated voltage can be lower.)

Fault indication output

Maximum safe voltage 40 V DC (Attention! Um is no rated voltage.)

Certificate PF 08 CERT 0803

Marking Ex-Hexagon II (3)G [Ex ic Gc] IIC

Input Ex ic

Voltage 10.5 V

Current 13 mA

Power 34 mW (linear characteristic)

Certificate TÜV 99 ATEX 1493 X

Marking Ex-Hexagon II 3G Ex ec nC IIC T4 Gc

Galvanic isolation

Input/Output safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V

Input/power supply safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V

Directive conformity

Directive 2014/34/EU EN IEC 60079-0:2018+AC:2020 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012 , EN IEC 60079-15:2019

 
 
 
 

Related Part Number:

 

KCD2-SCD-EX1 KFU8-UFT KFD0-CS-Ex1.51P NBB8-18GM50-A2-V1
KCD2-STC-EX1.20 K-HM26-2M-261533 KFD0-CS-Ex2.50P NBB8-18GM50-E0
KFD2-SR2-Ex1.W.LB NBB15-U1-E2 KFD0-CS-Ex2.51P NBB8-18GM50-E0-V1
KFD2-SR2-2.W.SM NBB1,5-5GM25-E2 KFD0-RO-Ex2 NBB8-18GM50-E2
KFD2-SR2-Ex2.W.SM NBB1,5-5GM25-E2-V3 KFD0-SCS-Ex1.55 NBB8-18GM50-E2-V1
KFD2-SR2-Ex2.2S NBB1,5-F79-E0 KFD0-SD2-Ex2.1045 NBB8-18GM50-E2-V1-M
KFD2-SR2-2.2S NBB1,5-F79-E2 KFD0-SD2-Ex2.1245 NBB8-18GM60-A2-V1
KFA6-DWB-EX1.D NBB15-U1-Z2 KFD0-TR-Ex1 NBB8-18GM60-US
KFA6-SR2-Ex2.W NBB5-18GM50-E2-V1 KFD0-CC-1 NBN3-8GM40-E2-V3
KFA6-SR-2.3L.FA NBB15-30GM30-E2-V1 KFD0-HMS-16 NBN3-F25F-E8-V1
KFA6-ER-1.5 NBB15-30GM50-A2-V1 KFD0-RSH-1.4S.PS2 NBN40-U1K-N0
KFA6-ER-1.6 NBB15-30GM50-E2 KFD0-SD2-EX1.10100 NBN40-U4LK-N0
KFA6-ER-1.W.LB NBB15-30GM50-E2-M KFD0-SD2-EX1.1045 NBVB15-U1.Z2
KFA6-ER-2.W.LB NBB15-30GM50-E2-V1 KFD2-UT2-1 NCB5-18GM40-NO
KFA6-ER-Ex1.W.LB NBB15-30GM50-E2-V1-M KFD2-CD-1.32 NJ10-30GM-N-5M
KFA6-SR-2.3L.FA NBB8-18GM30-E2 KFD2-CD-EX1.32 NJ15-30GK-N
KFA6-STR-1.24.4 NBB8-18GM30-E2-V1 KFD2-HMM-16 NJ2-12GK-SN
KFD0-CS-Ex1.50P NBB8-18GM60-A2-V1 KFD2-SH-EX1.T NJ2-12GM-N
KFD2-SH-Ex1.T.OP NJ4-12GK-SN KFD2-UT2-1 RD0-FB-EX4.COM
KFD2-SL2-EX2.B NJ5-18GK-N KFD2-VR4-EX1.26 SC3,5-G-N0
KFD2-SR2-EX1.W NJ5-18GK-N-150 KFU8-UFC-1.D SC3,5-G-N0-5M
KFD2-SR2-Ex2.W NJ5-18GM-N V15-G-2M SC3,5-G-N0-6M
KFD2-STC5-1.2O NJ8-18GK-N Z 787 SJ3,5-N
KFD2-STC5-Ex1 RD0-FB-EX4 Z787.H SJ3,5-S1N
KFD2-STC5-Ex1.H RD0-TI-Ex8.FF.* HIC2031 UPR-03
HIC2031 Z787.F Z787.H.F SJ3,5-N-BU

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Trading Company

  • Year Established:

    2010

  • Total Annual:

    5000000-8000000

  • Employee Number:

    100~150

  • Ecer Certification:

    Verified Supplier

  SC Automation Limited (hereinafter referred to as SC) was established in 2010 and is a company focused on international trade.We are committed to serving customers worldwide based on the principle of integrity. After years of experience, we have formed good cooperative relationships ...   SC Automation Limited (hereinafter referred to as SC) was established in 2010 and is a company focused on international trade.We are committed to serving customers worldwide based on the principle of integrity. After years of experience, we have formed good cooperative relationships ...

+ Read More

Get in touch with us

  • Reach Us
  • SC Automation Limited
  • Unit 1406B 14/F,The Belgian Bank Building, Nos. 721-725 Nathan Road, Mongkok, Kowloon,Hong kong.
  • https://www.industrialautomation-sensors.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement