China 0.5VV DC 45Hz 65Hz Digital Clamp Ampere Meter Overload Protection
China 0.5VV DC 45Hz 65Hz Digital Clamp Ampere Meter Overload Protection

  1. China 0.5VV DC 45Hz 65Hz Digital Clamp Ampere Meter Overload Protection
  2. China 0.5VV DC 45Hz 65Hz Digital Clamp Ampere Meter Overload Protection

0.5VV DC 45Hz 65Hz Digital Clamp Ampere Meter Overload Protection

  1. MOQ: 10pc
  2. Price: Negotiation
  3. Get Latest Price
Payment Terms T/T, Western Union,Paypal,L/C
Supply Ability 50000pcs/month
Delivery Time 5-35days
Packaging Details 1pcs/gift box, 30~50pcs/ctn
product name Best Clamp Meter For Electrician
Mode CHX-CM008A
Display LCD
AC Current range 400A
Resolution 0.1A
Accuracy ±(2.5% + 10)
Frequency 45Hz ~65Hz
Ambient temperature 23 ± 5 ℃
Brand Name CHX
Model Number CHX-CM008A
Certification CE, RoHS
Place of Origin CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, Western Union,Paypal,L/C Supply Ability 50000pcs/month
Delivery Time 5-35days Packaging Details 1pcs/gift box, 30~50pcs/ctn
product name Best Clamp Meter For Electrician Mode CHX-CM008A
Display LCD AC Current range 400A
Resolution 0.1A Accuracy ±(2.5% + 10)
Frequency 45Hz ~65Hz Ambient temperature 23 ± 5 ℃
Brand Name CHX Model Number CHX-CM008A
Certification CE, RoHS Place of Origin CHINA
High Light 0.5VV DC Ampere Clamp Meter45Hz Digital Clamp Ampere Meter65Hz Ampere Clamp Meter

0.5VV DC 45Hz ~ 65Hz Digital Clamp Infrared Themometer

 

3.2 Technical indicators

 

Environment temperature:23±5℃ Relative humidity:<75%

 

3.2.1 AC Current

 

Range Resolution Accuracy
6A 0.001A ±(3.0% + 20)
60A 0.01A ±(2.5% + 8)
400A 0.1A ±(2.5% + 10)

 

- Min input current:0.02A AC

- Max input:400A AC

- Frequency:45Hz ~65Hz

- When ac current is measured, the meter automatically opens an internal low-pass filter to filter out high-frequency current.

 

3.2.2 DC voltage

 

Range Resolution Accuracy
6V 0.001V ±(0.5% + 3)
60V 0.01V
600V 0.1V ±(0.8% + 5)

 

- Min/ input voltage:0.5VV DC

- Input impedance:10MW

- Maximum/ input voltage:600V AC (Effective value)OR 600V DC

 

3.2.4 AC voltage 

 

Range Resolution Accuracy
6V 0.001V

 

±(1.0% + 5)

60V 0.01V
600V 0.1V ±(1.2% + 5)

- Min/ input voltage:1.0V DC

- Input impedance:10MW

- Maximum/ input voltage:600V AC (Effective value)or 600V DC

- Frequency range:45Hz ~65Hz

 

 

3.2.5 Frequency 

 

3.2.5.1 Through the V file:

 

Range Resolution Accuracy
60.0Hz 0.1Hz ±(1.0% + 5)
1000Hz 1Hz

 

- Range:40Hz ~ 1000Hz

- Input range:≥ 0.2A AC(Effective value)

 

3.2.5.2 Through A File (From Clamp)

 

Range Resolution Accuracy
60.0Hz 0.1Hz ±(1.0% + 5)
1000Hz 1Hz

- Range:40Hz ~ 1000Hz

- Input range:≥ 1.0V AC(Effective value)

 

3.2.6 Resistance

 

Range Resolution Accuracy
6kW 0.001kW ±(0.8% + 3)
60kW 0.01kW
600kW 0.1kW
6MW 0.001MW ±(1.2% + 3)
10MW 0.1MW

 

- Overload protection: 600V DC or AC(Effective value)

 

 

Current measurement

 

1) Hold the trigger, open the pliers, and clamp a wire of the circuit under test in the pliers.
2) When the measured signal is greater than or equal to 0.02A, the main screen of the instrument will display the measured current value, and the secondary screen will display the frequency value of the current (note: the meter will only display the frequency value if the current is greater than or equal to 0.02A)

 

Noted


1) The correct measurement results cannot be obtained by clamping two or more wires of the circuit under test at the same time.
2) In order to obtain accurate readings, the conductor under test should be placed as far as possible in the center of the current clamp.
3)  Represents the maximum input ac current of 400 A.
4) Please hold the clamp head when the current measurement machine to open the clamp head and nose pliers head clip conductor under test, and then slowly let go of the trigger, until the clamp head closed completely, please be sure to test whether the conductor is picking up in the middle of the tong head, not in the tong head center will produce additional error, clamp table can only measure electrical conductor, a conductor if two or more current is measured at the same time, the measuring reading will be wrong.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2010

  • Total Annual:

    3000000-8000000

  • Employee Number:

    80~100

  • Ecer Certification:

    Active Member

Shenzhen Xishen Development Co.,LTD,business mogel for testing instruments for more than 10 years.Our engineers have been in this industry for over 20 years and served some of the most famous customers from all over the world.We can provide below services for all our partners in this ... Shenzhen Xishen Development Co.,LTD,business mogel for testing instruments for more than 10 years.Our engineers have been in this industry for over 20 years and served some of the most famous customers from all over the world.We can provide below services for all our partners in this ...

+ Read More

Get in touch with us

  • Reach Us
  • SHENZHEN XISHEN DEVELOPMENT COMPANLY LIMITED
  • 502, No. 31, Yangmei Road, Bantian Street, Shenzhen, Guangdong, China
  • https://www.smart-multimeter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement