Payment Terms | T/T, Western Union,Paypal,L/C |
Supply Ability | 50000pcs/month |
Delivery Time | 5-35days |
Packaging Details | 1pcs/gift box, 30~50pcs/ctn |
Mode | CHX-CM004 |
Display | LCD |
AC Current range | 60A |
Accuracy | ±(2.5% rdg + 8 digits) |
Resolution | 0.1A |
Max. input current | 600AAC |
Frequency range | 50Hz |
product name | Auto Range Digital Multimeter |
Brand Name | CHX |
Model Number | CHX-CM004 |
Certification | CE, RoHS |
Place of Origin | CHINA |
View Detail Information
Explore similar products
600V 750V Digital Clamp Multimeter 9.999Hz 99.99Hz With LCD Display
60A 0.01A Digital Clamp Tester , 400A AC DC Clamp On Amp Meter
400A AC Digital Clamp Multimeter Voltage Tester 1999 Display 190g
Data Keep Clamp On Digital Multimeter 190g 10MW 184.0×66.0×32.5mm
Product Specification
Payment Terms | T/T, Western Union,Paypal,L/C | Supply Ability | 50000pcs/month |
Delivery Time | 5-35days | Packaging Details | 1pcs/gift box, 30~50pcs/ctn |
Mode | CHX-CM004 | Display | LCD |
AC Current range | 60A | Accuracy | ±(2.5% rdg + 8 digits) |
Resolution | 0.1A | Max. input current | 600AAC |
Frequency range | 50Hz | product name | Auto Range Digital Multimeter |
Brand Name | CHX | Model Number | CHX-CM004 |
Certification | CE, RoHS | Place of Origin | CHINA |
High Light | 60A Digital Clamp Multimeter ,0.1A Digital Clamp Multimeter ,60A Manual Ranging Digital Multimeter |
Auto Ranging / Manual Ranging Digital Clamp Multimeter 1.5V AAA Battery
GENERAL SPEClIFICATIONS
TECHNICAL SPECIFICATIONS
Measuring range & accuracy
(Accuracy guaranteed at 23℃C±5℃C, humidity <75%)
Note: When measuring Sine waves with the true RMS method the meter may display a reading between 1-50A. This is normal and does not affect the accuracy of the meter.
AC Current
Range | Accuracy | Resolution |
60A | ±(2.5% rdg + 8 digits) | 0.01A |
600A | 0.1A |
Max. input current: 600AAC.
Frequency range: 50Hz.
DC Current
Range | Accuracy | Resolution |
60A | ±(2.0% rdg + 8 digits) | 0.01A |
600A | 0.1A |
Max. input current: 600AAC.
INRUSH Current
Range | Accuracy | Resolution |
60A | ±(5.0% rdg + 60 digits) | 0.01A |
600A | 1A |
Inrush measurement time: 100ms.
Amperage range: 20 ~ 600A.
Frequency range: 40 ~ 400Hz.
DC Voltage
Range | Accuracy | Resolution |
600mV | ±(0.8% rdg + 5 digits) | 0.1 mV |
6V | 0.001V | |
60V | 0.01V | |
600V | ±(1.0% rdg + 5 digits) | 0.1V |
Input impedance: 10MQ.
Max. input voltage: 600V AC (RMS) or 600V DC.
Frequency range: 40 ~ 1000Hz
Note:
In the low voltage range, with the test leads is not connected to the circuit under test, the Meter may have a fluctuating reading, this is normal, this it is caused by high sensitivity of the Meter, it does not affect the actual measurement results.
Company Details
Business Type:
Manufacturer
Year Established:
2010
Total Annual:
3000000-8000000
Employee Number:
80~100
Ecer Certification:
Active Member
Shenzhen Xishen Development Co.,LTD,business mogel for testing instruments for more than 10 years.Our engineers have been in this industry for over 20 years and served some of the most famous customers from all over the world.We can provide below services for all our partners in this ... Shenzhen Xishen Development Co.,LTD,business mogel for testing instruments for more than 10 years.Our engineers have been in this industry for over 20 years and served some of the most famous customers from all over the world.We can provide below services for all our partners in this ...
Get in touch with us
Leave a Message, we will call you back quickly!