Payment Terms | T/T, Western Union,Paypal,L/C |
Supply Ability | 50000pcs/month |
Delivery Time | 5-35days |
Packaging Details | 1pcs/gift box, 30~50pcs/ctn |
Mode | CHX-CM008B |
Display | LCD |
Resistance range | 200W |
Resolution | 0.1W |
Accuracy | ±(0.8% + 3) |
open-circuit voltage | About 0.4V |
product name | Digital Clamp Multimeter |
Ambient temperature | 23 ± 5 ℃ |
Brand Name | CHX |
Model Number | CHX-CM008B |
Certification | CE, RoHS |
Place of Origin | CHINA |
View Detail Information
Explore similar products
600V 750V Digital Clamp Multimeter 9.999Hz 99.99Hz With LCD Display
60A 0.01A Digital Clamp Tester , 400A AC DC Clamp On Amp Meter
400A AC Digital Clamp Multimeter Voltage Tester 1999 Display 190g
Data Keep Clamp On Digital Multimeter 190g 10MW 184.0×66.0×32.5mm
Product Specification
Payment Terms | T/T, Western Union,Paypal,L/C | Supply Ability | 50000pcs/month |
Delivery Time | 5-35days | Packaging Details | 1pcs/gift box, 30~50pcs/ctn |
Mode | CHX-CM008B | Display | LCD |
Resistance range | 200W | Resolution | 0.1W |
Accuracy | ±(0.8% + 3) | open-circuit voltage | About 0.4V |
product name | Digital Clamp Multimeter | Ambient temperature | 23 ± 5 ℃ |
Brand Name | CHX | Model Number | CHX-CM008B |
Certification | CE, RoHS | Place of Origin | CHINA |
High Light | 0.1W Clamp Digital Meter ,200W Clamp Digital Meter ,200W AC DC Clamp Multimeter |
Relative Measurement Digital Clamp Multimeter With NCV Zone
Maintenance
1.4.1 Please do not attempt to test lead the shell to adjust or repair instrument, this operation can only be fully understood by technicians
1.4.2 Before test leading the instrument bottom shell and the battery cover, should be removed the test lead from the measured line test lead
1.4.3 In order to avoid false readings may cause electric shock, when the instrument display “” symbol,
The battery should be replaced immediately.
1.4.4 Use a damp cloth and a mild detergent to clean the instrument; do not use abrasive detergents or solvents.
1.4.5 The instrument when not in use should turn off the power,
1.4.6 If you do not use a meter long time, the battery should be removed to prevent damage to the instrument.
2. Description
- The instrument is an professional measuring instrument with liquid crystal display and a back light source. The user readings in easily. Single hand operation with overload protection and low battery indicator. For professional, factory, school, lovers or family use, is an ideal Multi-function instrument.
- Used for AC DC voltage,AC current, frequency, resistance, capacitance measurement and the on-off circuit, measurement, temperature measurement .
- Automatic range
- Data keep
- Auto power off
- Relative measurement
Part name
⑴ Current clamp head: For current measurement
⑵ The torch of head lamp
⑶ Panel
⑷ NCV and alarm
⑸ Function selection(FUN)
⑹ LCD Monitor
⑺ Common socket
(8) Resistor, voltage, frequency and Continuity input jack
(9) Min and Max value (MAX/MIN)
(10) Reading / backlight button
(11) Function change button
(12) NCV zone
Overview
Automatic measurement and manual measurement
Overload protection
The maximum voltage allowed between the measuring terminal and earth:600V DC or 600V AC
Display:LCD
Maximum:1999 display
Polar indication:Automatic indicator,‘-’,Display negative
Over range display:‘0L’ or ‘-0L’.
Sampling time: about 3 times / sec
Display unit and power display
Automatic power off:15Minutes
Open Jaw is 25mm; test Line OD less than23mm
Battery type:1.5V AAA
Battery voltage indication:LCD Symbol
Temperature coefficient:less 0.1
operating temperature:18℃ ~ 28℃
Storage temperature:-10℃ ~ 50℃
Size:184.0×66.0×32.5mm
Weight:about 190g(Including battery)
3.2.1 AC Current
Range | Resolution | Accuracy |
2A | 0.001A | ±(4.0% + 20) |
20A | 0.01A | ±(2.5% + 8) |
200A | 0.1A | |
400A | 1.0A |
- Max input:400A AC
- Frequency:50Hz
- When ac current is measured, the meter automatically opens an internal low-pass filter to filter out high-frequency current.
3.2.2 DC voltage
Range | Resolution | Accuracy |
2V | 0.001V | ±(0.8% + 5) |
20V | 0.01V | |
200V | 0.1V | |
600V | 0.1V | ±(1.0% + 5) |
- Input impedance:10MW
- Maximum/ input voltage:600V AC (Effective value)OR 600V DC
3.2.4 AC voltage
Range | Resolution | Accuracy |
2V | 0.001V | ±(1.2% + 5) |
20V | 0.01V | |
200V | 0.1V | |
600V | 0.1V | ±(1.5% + 5) |
-Input impedance:10MW
- Maximum/ input voltage:600V AC (Effective value)or 600V DC
In the small voltage range, the meter pen is not connected to the measured circuit, the meter may have jumping reading, this is normal, because of the high sensitivity of the meter, does not affect the actual measurement results
3.2.5 Resistance
Range | Resolution | Accuracy |
200W | 0.1W | ±(0.8% + 3) |
2kW | 0.001kW | |
20kW | 0.01kW | |
200kW | 0.1kW | |
2MW | 0.001MW | ±(1.2% + 3) |
20MW | 0.1MW |
- open-circuit voltage:About 0.4V
- Overload protection:600V DC or AC(Effective value)
Company Details
Business Type:
Manufacturer
Year Established:
2010
Total Annual:
3000000-8000000
Employee Number:
80~100
Ecer Certification:
Active Member
Shenzhen Xishen Development Co.,LTD,business mogel for testing instruments for more than 10 years.Our engineers have been in this industry for over 20 years and served some of the most famous customers from all over the world.We can provide below services for all our partners in this ... Shenzhen Xishen Development Co.,LTD,business mogel for testing instruments for more than 10 years.Our engineers have been in this industry for over 20 years and served some of the most famous customers from all over the world.We can provide below services for all our partners in this ...
Get in touch with us
Leave a Message, we will call you back quickly!