Payment Terms | T/T |
Supply Ability | 30SET/MONTH |
Delivery Time | 15 DAYS After Deposit |
Packaging Details | With regular Film and Carton |
Minimum dimensions recommended | Length ≥15m × Width ≥6m × Height ≥4.5m |
Walls/roof | Double-layer insulated color steel panels (rock wool core) |
Framework | Galvanized steel structure for corrosion resistance and dynamic load capacity |
Lighting | Explosion-proof LED strips (illuminance ≥800 Lux) to ensure uniform coating |
Airflow calculation | ≥100 air exchanges per hour |
Heating systems | oil-fired, gas-fired, and electric heating |
Filtration system | intake pre-filter, top-mounted HEPA filter, exhaust fiberglass and activated carbon filters |
Control system | spraying, heated spraying, paint baking, baking time setting, lighting switch, emergency stop switch, and safety devices |
Brand Name | Coarrech |
Model Number | CT-DQ-15 |
Certification | ISO9001、CE |
Place of Origin | CHINA |
View Detail Information
Explore similar products
Heavy-Duty/Oversized Bus Maintenance, Spray Painting & Drying Systems
Reliable Performance Industrial Grade Spray Booth for Heavy-Duty Applications
Robust Exterior Dimensions Of Our Spray Booth For Heavy-Duty
Industrial Grade Spray Booth with Front Door and Working Doors for Sturdy
Product Specification
Payment Terms | T/T | Supply Ability | 30SET/MONTH |
Delivery Time | 15 DAYS After Deposit | Packaging Details | With regular Film and Carton |
Minimum dimensions recommended | Length ≥15m × Width ≥6m × Height ≥4.5m | Walls/roof | Double-layer insulated color steel panels (rock wool core) |
Framework | Galvanized steel structure for corrosion resistance and dynamic load capacity | Lighting | Explosion-proof LED strips (illuminance ≥800 Lux) to ensure uniform coating |
Airflow calculation | ≥100 air exchanges per hour | Heating systems | oil-fired, gas-fired, and electric heating |
Filtration system | intake pre-filter, top-mounted HEPA filter, exhaust fiberglass and activated carbon filters | Control system | spraying, heated spraying, paint baking, baking time setting, lighting switch, emergency stop switch, and safety devices |
Brand Name | Coarrech | Model Number | CT-DQ-15 |
Certification | ISO9001、CE | Place of Origin | CHINA |
High Light | Heavy Duty Spray Painting Equipment ,Large Buses Spray Painting Equipment ,Baking Spray Painting Equipment |
I. Core Design Parameters
Dimensional Requirements
Minimum dimensions recommended: Length ≥15m × Width ≥6m × Height ≥4.5m (to accommodate double-decker buses or extended trucks).
Modular design: Expandable structure for future extensions (e.g., additional workstations or increased height).
Structural Materials
Framework: Galvanized steel structure for corrosion resistance and dynamic load capacity.
Walls/roof: Double-layer insulated color steel panels (rock wool core) for thermal insulation and noise reduction.
Flooring: Anti-static epoxy flooring with anti-slip texture to prevent paint mist accumulation.
II. Key Equipment Selection
Spray System
Dust-free environment: Three-stage filtration (primary + intermediate + high-efficiency filters, ≥98% efficiency).
Spray equipment: High-pressure airless spray guns (flow rate ≥20L/min) with adjustable nozzles for large-area coverage.
Lighting: Explosion-proof LED strips (illuminance ≥800 Lux) to ensure uniform coating.
Curing Oven System
Energy options:
Gas heating: ≥85% thermal efficiency, ideal for continuous operation.
Electric heating: Lower upfront cost but higher operational expenses (dependent on local electricity rates).
Temperature control: PID-regulated ±2°C accuracy, curing temperatures adjustable between 60–80°C based on paint specifications.
Ventilation System
Airflow calculation: ≥100 air exchanges per hour (e.g., 150,000 m³/h for a 30m×10m×5m space).
Energy-saving design: Heat recovery devices (e.g., heat exchangers) reduce energy consumption by ≥30%.
III. Safety & Environmental Compliance
Safety Measures
Explosion-proof design: ATEX/IECEx-certified electrical equipment and ventilation motors.
Fire protection: Automatic sprinklers + combustible gas detectors linked to emergency exhaust.
Emergency protocols: Emergency stop buttons and escape routes (width ≥1.2m).
Environmental Requirements
Waste gas treatment:VOC removal: Activated carbon adsorption + RCO catalytic combustion (≥90% efficiency).
Particulate filtration: Wet scrubbers or bag dust collectors.
Noise control: Soundproofing for equipment (≤75 dB(A)).
Company Details
Year Established:
1999
Total Annual:
3millions-5millions
Employee Number:
180~220
Ecer Certification:
Verified Supplier
CoatTech At CoatTech, we pride ourselves on our expertise in customized technology solutions. Our engineers and sales managers are passionate about the products we design and sell. Our sincere service has earned the trust of our clients. CoatTe... CoatTech At CoatTech, we pride ourselves on our expertise in customized technology solutions. Our engineers and sales managers are passionate about the products we design and sell. Our sincere service has earned the trust of our clients. CoatTe...