Payment Terms | T/T in advance, LC AT SIGHT |
Supply Ability | 10 pcs per month |
Delivery Time | 35 working days after received your payment |
Packaging Details | Solid plywood case suitable for long distance transportation |
Product Name | Medical Autoclave Sterilizer |
Design pressure | 0.3Mpa |
Chamber material | SS304 material |
Jacket material | SS304 material |
Power | AC 380V,3ψ,50Hz |
Water | 1~3kg/cm3 |
Steam | 4~5kg/cm3 |
Air | 4~5kg/cm3 |
Brand Name | Medpharm |
Model Number | MD-1.2Y |
Certification | CE/SGS |
Place of Origin | China |
View Detail Information
Explore similar products
PLC System Large Pharmaceutical Autoclave Steam Sterilizer With Horizontal
Program Automatic Controlled Large Steam Sterilizer With Indicating Lights
Rectangular Single Ended Construction Large Steam Sterilizer With Visually And
Safety Interlock Medical Waste Large Steam Sterilizer with thermally insulated
Product Specification
Payment Terms | T/T in advance, LC AT SIGHT | Supply Ability | 10 pcs per month |
Delivery Time | 35 working days after received your payment | Packaging Details | Solid plywood case suitable for long distance transportation |
Product Name | Medical Autoclave Sterilizer | Design pressure | 0.3Mpa |
Chamber material | SS304 material | Jacket material | SS304 material |
Power | AC 380V,3ψ,50Hz | Water | 1~3kg/cm3 |
Steam | 4~5kg/cm3 | Air | 4~5kg/cm3 |
Brand Name | Medpharm | Model Number | MD-1.2Y |
Certification | CE/SGS | Place of Origin | China |
High Light | Steam Autoclave Sterilizer ,Healthcare Sterilizer |
1200 Liter Large Steam Sterilizer With Safety Valves In Jacket And Chamber
Specification
Model No | MD-1.2Y | |
Chamber dimensions | mm | 680*1180*1500 |
Overall dimensions | mm | 2200*2000*1910 |
Inner capacity | L | 1200 |
Door operation | AUTO | Horizontal single sliding |
Setting range time | min | 0~99 |
Setting range temperature | ℃ | 110~135 |
Controller | Panel | Touch screen |
System | PLC | |
Display | 5.7" Touch Screen | |
Version | Chinese/English/Spanish/Thai | |
Output interface | RS-232 | |
Vacuum | Drawing | Vacuum pump |
Printer | Paper | Heat sensitive type with auto rolling back |
Accessories | Trolley | 1 set of floor-Loading carriage |
Printer paper | 2 rolls | |
Manual | 1 copy of operation and maintenance manual |
Program Parameter
Cycle name | Further details | Application |
Instruments/Tools | 3 times Vacuum, expose temperature 132℃, expose time 8 min, drying time 5 min. | Solid materials to be sterilized: |
Clothing | 3 times Vacuum, expose temperature 121℃, expose time 15 min, drying time 25 min. | Materials to be sterilized from which air can’t be easily displaced |
User Programmable | All preset parameters can be reset; Multiple customized programs can be set and stored by user. | Customized |
Test programs | ||
B-D Test | 3 times Vacuum, expose temperature 134℃, expose time 4 min, drying time 3 min. | Test program |
Vacuum Leakage Test | Test the chamber connecting parts’ tightness effect. It’s important to ensure the sterilization effect. | Test program |
Description of sterilization cycle
Pre-Vacuum Cycle - pre-conditioning of load during air removal using programmable ramped
positive and negative pressure pulsing to remove entrapped air. Programmable ramped vacuum
drying.
Micro Isolator Cycle - pre-vacuum cycle using programmable, ramped, positive and negative pressure pulsing to reduce internal and external crazing of animal housing by allowing pressure stabilization to product items being processed.
Test Cycles Leak Test - programmable vacuum leak test to verify door seal, sterilizer chambe
r and piping integrity through monitoring of acceptable vacuum loss over selected time.
Autoclave air removal test - pre-programmed vacuum cycle used to verify removal of residual air from
chamber and load, and ensure steam penetration into the test load.
Bio-Waste Cycle - designed for pre-sterilization conditioning through positive and negative pressurization to ensure air removal from mixed products in containers. Programmable ramped steam pressurization is used to maximize heat penetration of mixed laboratory biohazard waste.
F0 Temperature Control Cycle - for the sterilization of heat sensitive materials using time-at-temperature calculations beginning at a predetermined point of the conditioning phase. This reduces the product exposure to higher temperatures normally found in standard sterilization cycles.
Gravity Cycle - for non-air retentive products; utilizes positive steam pressure with vacuum assist air removal for conditioning of load. The end of cycle exhaust is programmable for dry and non-dry phases
Liquid Cycles Liquid Cycle - cycle used for liquids in vented borosilicate glass or metal containers. Positive steam pressure with vacuum assisted air removal with programmable ramped heating and exhaust to ambient with optional cooling phase.
Liquid, Air Cool Cycle - cycle used for liquids in vented borosilicate glass or metal containers
. Positive steam pressure with vacuum assisted air removal with programmable ramped
heating and introduction of filtered air during exhuast to speed cooling.
Pre-Vacuum Liquid Cycle - pre-conditioning of load using programmable, ramped, positive
and negative pressure pulsing to assist in removal of entrapped air. Chamber temperatures
at negative pressures are controlled to prevent boiling of product. Controlled ramped exhaust
to ambient with optional cooling phase.
Effluent - for the processing of items in BSL3 and BSL4 laboratories. The cycle uses a heated,
jacketed, 0.2 micron hydrophobic filter to contain biohazard contents in sterilizer chamber
while allowing exhaust of sterile gasses.
Advantages
Reliability - Industrial grade valves and high temperature gaskets prevent otherwise costly
and common service downtime. The vessel is tested and certified to exceed national pressure
vessel standards and carries a manufacturer’s warranty.
Safety - Operator and technician safety is ensured through temperature and pressure monitoring,
relief valves, safety interlocks overrides.
Serviceability - Reduce costly maintenance downtime with easy to access consumable and
expendable components.
Simplicity - The intuitive touch screen interface provides users with clearly identifiable selections
to begin cycles.
Long Life Door Gasket - Medpharm high temperature, air actuated door gaskets are seated
into a machined groove that provides a close tolerance creating a less strenuous environment,
extending door gasket life.
Brochure load down from here
Medpharm medical large steam autoclave brochure.pdf
Company Details
Business Type:
Manufacturer,Trading Company
Ecer Certification:
Verified Supplier
MEDPHARM Company team is committed to providing quality sterilization products, service, parts and maintenance training at significant savings. From customized parts packages to turnkey&n... MEDPHARM Company team is committed to providing quality sterilization products, service, parts and maintenance training at significant savings. From customized parts packages to turnkey&n...
Get in touch with us
Leave a Message, we will call you back quickly!