China factories

China factory - Beijing Ding Ding Future Technology Co.Ltd

Beijing Ding Ding Future Technology Co.Ltd

  • China,Beijing ,Beijing
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China UMP-400-48 UMP-400-24 Rectifier Module
China UMP-400-48 UMP-400-24 Rectifier Module

  1. China UMP-400-48 UMP-400-24 Rectifier Module
  2. China UMP-400-48 UMP-400-24 Rectifier Module

UMP-400-48 UMP-400-24 Rectifier Module

  1. MOQ: 1 piece
  2. Price: USD 299
  3. Get Latest Price
Payment Terms L/C, T/T
Supply Ability 3000 pieces per month
Delivery Time 8-10 weeks
Packaging Details cartons
Brand MEAN WELL
Product Name UMPS series
Output currency 16.7A/8.3A
Rated power 400W
Input frequency 47 ~ 63Hz
DC voltgae 22.8 ~ 25.2V / 45.6 ~ 50.4V
Input Voltage 90 ~ 264VAC / 127 ~370VDC
Protection over voltgae / over load
Dimension 250*89*37mm (L*W*H)
Weight 0.88kg
Brand Name MEAN WELL
Model Number ump-400-24 /UMP-400-48
Certification CE
Place of Origin CN

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, T/T Supply Ability 3000 pieces per month
Delivery Time 8-10 weeks Packaging Details cartons
Brand MEAN WELL Product Name UMPS series
Output currency 16.7A/8.3A Rated power 400W
Input frequency 47 ~ 63Hz DC voltgae 22.8 ~ 25.2V / 45.6 ~ 50.4V
Input Voltage 90 ~ 264VAC / 127 ~370VDC Protection over voltgae / over load
Dimension 250*89*37mm (L*W*H) Weight 0.88kg
Brand Name MEAN WELL Model Number ump-400-24 /UMP-400-48
Certification CE Place of Origin CN
High Light UMP-400-48 Rectifier ModuleUMP-400-24 Rectifier ModuleMeanwell UMP-400-24

 

Mean Well UMP Series UMP-400 Series UMP-400-24 UMP-400-48 Rectifier Module

 

Features :

Fan-less, 1U design

Modular design, with DC-DC module cards (NID35/65/100 series models)

Can be used as a single rail PSU

wide operating temperature ranges from -30 ~ +70 ° C

Meet OVC III requirements

Meet 2x MOPP isolation requirements, ideal for BF rated medical equipment

 

Technical 

 

MODEL UMP-400-24 UMP-400-48

 

 

 

SINGLE OUTPUT

(Standard model)

DC VOLTAGE 24V 48V
RATED CURRENT 16.7A 8.3A
RATED OUTPUT POWER 400W max.
VOLTAGE ADJ. RANGE 22.8 ~ 25.2V 45.6 ~ 50.4V
RIPPLE & NOISE (max.) Note.2 240mVp-p 360mVp-p
VOLTAGE TOLERANCE Note.3 ±1.0% ±1.0%
LINE REGULATION ±0.5% ±0.5%
LOAD REGULATION ±1.0% ±1.0%
SETUP, RISE TIME 1000ms, 50ms/230Vac ; 2000ms, 50ms/115Vac
HOLD UP TIME (Typ.) 12ms@230Vac ; 12ms@115Vac

MULTIPLE OUTPUT

(Optional Model)

DC VOLTAGE CH1 output 24V or 48V + NID DC modules for CH2,3,4
TOTAL OUTPUT POWER CH2,3,4 output power can be flexible depending on NID selection. Combined power on all channels must not exceed 400W

 

 

 

INPUT

VOLTAGE RANGE Note.4 90 ~ 264VAC 127 ~370VDC
FREQUENCY RANGE 47 ~ 63Hz
POWER FACTOR PF>0.95/230VAC PF>0.98/115VAC at full load
EFFICIENCY(Typ.) Note.5 88.5%, full case load with each type of module at nominal voltage
AC CURRENT 2.5A/230VAC 4.7A/115VAC
INRUSH CURRENT 40A/230VAC 25A/115VAC
LEAKAGE CURRENT Earth leakage current <300uA / 264VAC, Touch current <100uA/264VAC

 

 

PROTECTION

OVERLOAD 105 ~ 135% rated output power
Protection type CH1: constant current limiting protection ( If a long short circuit continues, the OTP action will be triggered ), CH2,CH3,CH4: Hiccup mode protection
OVER VOLTAGE 26.4 ~ 31.2V 52.8 ~ 62.4V
Protection type: shut down o/p voltage, re-power on to recover
OVER TEMPERATURE Shut down o/p voltage, re-power on to recover

 

 

ENVIRONMENT

WORKING TEMP. -30 ~ +70℃ (Refer to "Derating Curve")
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP. -40 ~ +85℃
TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 50℃)
VIBRATION 10~500Hz, 2G 10min./1 cycle, 60 min. each along X, Y, Z axes
OPERATING ALTITUDE Note.6 5000 meters /OVCⅡ
OVER VOLTAGE GATEGORY Ⅲ; According to IEC62368-1; altitude up to 2000 meters

 

 

 

 

 

 

 

 

 

SAFETY & EMC

(Note 7)

SAFETY STANDARDS EAC TP TC 004; UL62368-1, Dekra seal BS EN/EN62368-1 approved; Design refer to ANSI/AAMI ES60601-1, TUV BS EN/EN60601-1, IEC 60601-1 (3rd edition)
ISOLATION LEVEL Primary-Secondary: 2x MOPP, Primary-Earth: 1x MOPP
WITHSTAND VOLTAGE I/P-O/P: 4KVAC I/P-FG: 2KVAC O/P-FG: 1.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC / 25℃/ 70% RH

 

 

EMC EMISSION

Parameter Standard Test Level / Note
Conducted BS EN/EN55032 (CISPR32) / Design refer to BS EN/EN55011 (CISPR11) Class B
Radiated BS EN/EN55032 (CISPR32) / Design refer to BS EN/EN55011 (CISPR11) Class B
Harmonic Current BS EN/EN61000-3-2 Class A
Voltage Flicker BS EN/EN61000-3-3 -----

 

 

 

 

EMC IMMUNITY

BS EN/EN55035; Design refer to BS EN/EN60601-1-2
Parameter Standard Test Level / Note
ESD BS EN/EN61000-4-2 Level 4, 8KV air; Level 4, 4KV contact
RF field BS EN/EN61000-4-3 Level 3, 3V/m
EFT/ Burst BS EN/EN61000-4-4 Level 3, 1KV
Surge BS EN/EN61000-4-5 Level 4, 2KV/Line-FG; 1KV/Line-Line
Conducted BS EN/EN61000-4-6 Level 2, 3V
Magnetic Field BS EN/EN61000-4-8 Level 1, 1A/m
Voltage Dips and Interruptions BS EN/EN61000-4-11

100% dip 1 periods, 30% dip 25 periods,

100% interruptions 250 periods

 

OTHERS

MTBF 1428.4K hrs min. Telcordia SR-332 (Bellcore) ; 187.3K hrs min. MIL-HDBK-217F (25℃)
DIMENSION 250*89*37mm (L*W*H)
PACKING 0.88Kg; 14pcs/13Kg/0.89CUFT

 

 

 

NOTE

1. All parameters NOT specifically mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor.

3. Tolerance: includes set up tolerance, line regulation and load regulation.

4. De-rating may be needed under low input voltages. Please check the derating curve for more details.

5. The efficiency changes by installing different output modules.

6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m (6500ft).

7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by

mounting the unit on a 450mm*450mm metal plate with 3mm of thickness. The final equipment must be re-confirmed that it still meets

EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”

(as available on http://www.meanwell.com)

※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

 


 


 



 

 
 
Solutions
We provide a complete solutions including site survey, propose professional plan according to customer’s request ,technical support, and maintenance service for Telecommunication Companies in and out of China. We have a competent team and a network of trusted Partners around the world.
 
FAQ :
1. How do you control the quality?
A:All products before the shipment are simulated usage scenarios, load and full load and current sharing test to ensure the quality of the product.
 
2. What is your minimum order quantity?
A:There is no minimum order quantity, and one can also be done. The only difference is the price and schedule.
 
3. Can you introduce your company?
A:I am very honored. I will send you the company’s introduction document later to give you a more comprehensive and direct introduction to our company’s information.
 
4. What are the advantages of your company?
A:Adequate inventory, and supply guarantee for the subsequent renewal of supply, flexible provided according to different to different needs of customers, providing different solutions.
 
5. Can i send samples?Report it to me along with the price?
A:You can send samples, the samples are subject to large pride, and the freight needs to be borne by you.
 
6. How do your company deal with the problem on quality?
A:Our company has been doing this industry for almost 10 years. It has already had a certain reputation. We will carefully analyze it. If it is indeed our quality problem, you can rest assured that it will do things according to the contract agreement and will never let you have any after the worries, our service team will be happy to serve you.
 
7 What about the quality ?
A:100% original with new package. we will test each item before posted to make sure each item with good quality.
8 How many months for guarantee ?
A: 1 year quality guarantee
9 How to deal with any inferior -quality goods ?
A: Goods can be post by with our charge of post fee for any bad quality products within guarantee time.
 

 
 
 
 
 
 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler,Agent,Trading Company

  • Year Established:

    2017

  • Total Annual:

    4,000,000-5,000,000

  • Employee Number:

    20~30

  • Ecer Certification:

    Verified Supplier

Ding Ding Future Power Company provide professional solutions to the telecommunications and network power industries across Africa,the Middle East , South America and Southeast Asia clients.   we have grown rapidly since our inception in 2017 as a small company for telecom after-sale serv... Ding Ding Future Power Company provide professional solutions to the telecommunications and network power industries across Africa,the Middle East , South America and Southeast Asia clients.   we have grown rapidly since our inception in 2017 as a small company for telecom after-sale serv...

+ Read More

Get in touch with us

  • Reach Us
  • Beijing Ding Ding Future Technology Co.Ltd
  • No 803,Unit 3 ,DaDou Road, Huihao Building .Fangshan District,Beijing,China
  • https://www.telecompowersystem.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement