China Jd-8002 Temperature And Humidity Box Heating Time ≤5-8 °c/min High Temperature
China Jd-8002 Temperature And Humidity Box Heating Time ≤5-8 °c/min High Temperature

  1. China Jd-8002 Temperature And Humidity Box Heating Time ≤5-8 °c/min High Temperature
  2. China Jd-8002 Temperature And Humidity Box Heating Time ≤5-8 °c/min High Temperature

Jd-8002 Temperature And Humidity Box Heating Time ≤5-8 °c/min High Temperature

  1. MOQ: 1
  2. Price: Negotiate
  3. Get Latest Price
Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram,In cash, escrow
Supply Ability 80 sets per month
Delivery Time 20 workdays after order confirmed
Packaging Details standard export plywood
Temperature range Section B: RT+10~500°C
Inner box size 400mm × 450mm × 450mm
Accuracy Control accuracy ±1 °C
Distribution temperature ±2.5 °C% (no load)
Heating time ≤5-8°C/min
Power 5KW
Brand Name JIEDONG
Model Number JD-8002
Place of Origin Guangdong, China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram,In cash, escrow Supply Ability 80 sets per month
Delivery Time 20 workdays after order confirmed Packaging Details standard export plywood
Temperature range Section B: RT+10~500°C Inner box size 400mm × 450mm × 450mm
Accuracy Control accuracy ±1 °C Distribution temperature ±2.5 °C% (no load)
Heating time ≤5-8°C/min Power 5KW
Brand Name JIEDONG Model Number JD-8002
Place of Origin Guangdong, China
High Light temperature and humidity test chamberhumidity test chamber

 
Jd-8002 Temperature And Humidity Box Heating Time ≤5-8 °c/min High Temperature Oven
 
 
Manufacturing Overview:
 
The high temperature safety oven is designed and manufactured according to the national standard (JB/T 5520-91 drying box technical conditions), and is widely used in petroleum, chemical, composite materials, electronics, medical pharmacy, scientific research laboratories and other related production and research fields. Used for drying, baking, heat treatment, etc. of articles. This device has the following basic features:
 Adopt centrifugal multi-wing fan circulation system, unique air duct structure, stable temperature control and uniform temperature field. The manufacturing process specification is beautiful in appearance, convenient in operation and maintenance, and the buyer only needs to provide power and meet the required working environment.
 The matching of components and assembly is good. The main functional components are all original parts with international advanced level.
The temperature adopts intelligent digital display temperature control system. The control system adopts digital display and has PID control function. It can realize automatic operation of test program, and can automatically combine subsystems such as heating and fan to ensure high quality control of the whole temperature system. .
 Designed with a safe venting hole, located at the rear of the box, can automatically discharge pressure when the gas expands in the working chamber, to avoid damage to the door when the gas inside the studio expands and further damage the staff.
 The control system is equipped with a stand-alone digital over-temperature power-off protection system, which can be used with confidence when unattended.
 Configure high temperature resistant graphite sealing strips, humanized environmental awareness, and protect the health of users.

 
 
First, the main technical indicators:
 

  1.1   Temperature range:   R.T.+10°C~500°C;
  1.2   Temperature fluctuation:   ≤ ± 1 ° C
  1.3   Temperature uniformity   ≤ ± 2.5% ° C
  1.4   Heating time   ≤5-8 °C/min
  1.5   Power   5KW
  1.6   Power supply voltage   220V 50HZ

 
Second, the room structure characteristics:
2.1 Structure: The horizontal integrated structure is used, and the control operating system is located on the upper side of the studio.
2.2 Box outer wall material: It is made of 1.5mm cold-rolled steel plate, and the outer surface is electrostatically sprayed;
2.3 Box body wall material: made of 304 stainless steel plate;
2.4 Gate and insulation sealing material: single door, high density asbestos,
2.5 partition: 2 layers, adjustable up and down;

 
 
Third, the air conditioning system:
3.1 Temperature control mode: Balanced temperature regulation (BTC), temperature difference with temperature control mode (TB). The method not only controls the output of the heater through the PID automatic calculation output according to the set temperature point, but also compensates for the heat loss, and finally achieves a dynamic balance control method.
3.2 Air circulation device: There are 2 high-temperature resistant stainless steel long-axis centrifugal multi-wing fans in the air conditioning room. The unique air duct forced closed circulation mode is used to push the circulating airflow through the heater to the working chamber, which greatly improves the air flow. And heat exchange capacity with the heater, thereby greatly improving the temperature uniformity.
3.3 Air heating mode: stainless steel closed electric heating tube, non-contact control (solid state relay).

 
 
Fourth, the control system
4.1 Control platform Shanghai Haihong intelligent temperature controller;
4.2 Display mode LED digital tube display;
4.3 Setting method Film type button input;
4.4 Operation mode Fixed value operation mode, full digital PID self-tuning adjustment;
4.5 Setting range Temperature: 0~500°C;
4.6 Resolution Temperature: 1 ° C;
4.7 Other functions Heating and over-temperature LED dynamic prompts;
4.8 Control Features Modular PID control with high precision and stable control;
Thin-film buttons for setting and digital calibration are convenient and simple;
LED digital display, intuitive and easy to read.

 
 
Five, safety protection device
5.1 Safe and reliable grounding device;
5.2 studio digital over-temperature protection; (optional)
5.3 Heater short circuit, motor overheating heat, leakage protection;
5.4 Alarm device: sound and light alarm. (optional)

 
 
Sixth, equipment use conditions
6.1 Working voltage
Frequency and error: 50±0.5Hz;
Voltage and error: AC 220±10%V, three-phase five-wire system;
Main power switch: aerodynamic switch with leakage protection;
6.2 Spatial location:
For ventilation, operation and maintenance, please place the equipment according to the space requirements listed below;
At least one space should be left around the equipment, ie ≥800mm;
The space at which the door of the device is opened can be arbitrarily switched.
6.3 Environmental conditions around the equipment
Temperature range: 5 ~ 40 ° C;
Humidity range: ≤85%R.H.;
Atmospheric pressure: 86 ~ 106KPa;
Ground requirements: smooth, well ventilated;
Ambient air quality requirements: no high concentration of dust and flammable, explosive gas or dust, no strong electromagnetic radiation source nearby.

 
 
Seven, product implementation standards:
7.1 JB/T 5520-91 drying oven technical conditions.
 
 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Seller

  • Year Established:

    2012

  • Total Annual:

    300-500

  • Employee Number:

    100~200

  • Ecer Certification:

    Active Member

                                                              Dongguan Jiedong Test Equipment Co., Ltd.           ...                                                               Dongguan Jiedong Test Equipment Co., Ltd.           ...

+ Read More

Get in touch with us

  • Reach Us
  • Dongguan jie dong test equipment co.,LTD