Payment Terms | L/C,D/A,D/P,T/T,Western Union,MoneyGram,In cash, escrow |
Supply Ability | 80 sets per month |
Delivery Time | 20 workdays after order confirmed |
Packaging Details | standard export plywood |
Nominal internal volume | (8)m³ |
Inner box size | W(2000 )mm × H(2000 )mm × D(2000 )mm |
Dimensions | W(3700 )mm × H(2300 )mm × D(1300 )mm |
Weight | (1200 )KG |
temperature range | 10℃ |
control precision | Temperature ± 0.2 ° C |
Heating time | 2 ° C / min |
Cooling time | 0.75~1℃/min |
Brand Name | JIEDONG |
Model Number | JD-8m³ |
Place of Origin | Guangdong, China |
View Detail Information
Explore similar products
80L Temperature Humidity Chamber 80l Programmable Constant JD-8001B-80
Stainless Steel Temperature Humidity Test Chamber Low Temperature Test -70°c--0
3a Current Temperature Humidity Chamber 800 Constant IEC60068-2-2
Programmable Constant Temperature And Humidity Test Chamber 150l Stainless Steel
Product Specification
Payment Terms | L/C,D/A,D/P,T/T,Western Union,MoneyGram,In cash, escrow | Supply Ability | 80 sets per month |
Delivery Time | 20 workdays after order confirmed | Packaging Details | standard export plywood |
Nominal internal volume | (8)m³ | Inner box size | W(2000 )mm × H(2000 )mm × D(2000 )mm |
Dimensions | W(3700 )mm × H(2300 )mm × D(1300 )mm | Weight | (1200 )KG |
temperature range | 10℃ | control precision | Temperature ± 0.2 ° C |
Heating time | 2 ° C / min | Cooling time | 0.75~1℃/min |
Brand Name | JIEDONG | Model Number | JD-8m³ |
Place of Origin | Guangdong, China | ||
High Light | temperature and humidity test chamber ,humidity test chamber |
Jd-8m3 temperature Humidity Chamber Constant Temperature And Humidity Chamber
(2) Technical agreement
Product number |
Walk-in constant temperature and humidity chamber JD-8m3 |
|
This test equipment is prohibited:
Testing or storage of flammable, explosive, volatile materials
Testing or storage of corrosive substance samples
Testing or storage of biological samples
Testing or storage of samples of strong electromagnetic emission sources
Testing or storage of radioactive material samples
Testing or storage of highly toxic substances
Testing or storage of specimens that may cause flammable, explosive, volatile, highly toxic, corrosive and radioactive materials during testing or storage
|
3.Volume, size and weight
|
|
|
(8)m³ |
|
W(2000 )mm × H(2000 )mm × D(2000 )mm |
|
W(3700 )mm × H(2300 )mm × D(1300 )mm |
|
(1200 )KG |
|
|
|
The ambient temperature is +5~+28°C, the relative humidity is ≤85%, and there is no sample under the test chamber.
|
3.2. Test method |
GB/T 5170.2-2008 temperature test equipment
GB/T 5170.5-2008 damp heat test equipment
|
|
10℃ |
|
Temperature: ±0.2 °C
(refers to the difference between the controller set value and the measured value of the controller)
|
|
≤0.5°C (temperature fluctuation is half of the difference between the highest temperature and the lowest temperature measured at the center point)
|
|
≤±1°C (the average temperature of the display temperature controller minus the average temperature measured at the center point)
|
|
≤2.0°C (temperature uniformity is the arithmetic mean of the difference between the measured maximum temperature and the lowest temperature in each test)
|
|
2 ° C / min (non-linear no-load) |
|
0.75~1°C/min (non-linear no-load) |
3.9. Working noise |
A sound level ≤ 70dB (A)
(Measured in a soundproof room with a ring temperature of 25 ° C and less echo; use A weighting to test the average of 8 points; each test point is 1 m away from the noise source and 1 m above the ground)
|
3.9. Satisfy the test method
|
GB/T2423.1-2008 (IEC60068-2-1:2007) Low temperature test method Ab
GB/T2423.2-2008 (IEC60068-2-2:2007) High temperature test method Bb
GJB150.4-1986 Low temperature test
GJB150.3-1986 high temperature test
GB/T2423.3-2006 (IEC60068-2-78:2007) constant damp heat test method Cab
GB/T2423.4-2008 (IEC60068-2-30:2005) Alternating damp heat test method Db
GJB150.9-1986 Damp heat test (Figure 1, Figure 2)
(The heat capacity of steel with a load of not more than 35kg/m3 per cubic meter, no active wet and hot load during the damp heat test) |
|
|
4.1. Thermal insulation structure
|
1. Outer wall material: high quality color steel plate
2. Inner wall material: high quality SUS#304 stainless steel plate
3. Box insulation material: rigid polyurethane foam + fiberglass
|
4.1. Air conditioning channel
|
1. Adopt multi-blade centrifugal circulation fan, strengthen the shaft and add high-low temperature resistant rotating blade aluminum alloy to achieve forced convection.
2. FLOW THROW air supply mode; horizontal diffusion vertical heat exchange arc cycle. 3. Adjustable side air outlet and guard return air outlet.
|
4.1. Test box standard configuration
|
1. Observation window: 1 transparent tempered glass hollow tempered glass (located on the door)
2. Lead hole: φ50mm 1 (on the left side of the box)
3. Indoor lighting on the door (high efficiency and long life energy saving lamp)
4. Host computer communication software CD, U disk interface, RS23 communication interface, misoperation hardware lock LOCK, communication cable 1 |
|
Double-open hinged door (left hinge, right handle when facing the cabinet), with observation window, lighting, window frame/door frame anti-condensation electric heating device, door opening size: (1.6)M
|
|
Controller display, U disk interface, RS232 computer communication interface, misoperation hardware lock LOCK, power switch, emergency stop switch, status indicator and sound and light alarm device
|
4.3. Mechanical room |
Refrigeration unit, water tray, drain hole
Condenser, plate heat exchanger, wind motor
Freezing system safety protection device (see configuration list for details)
|
|
IO board, machine tool transformer, ballast, intermediate relay, time relay, solid state relay, AC contactor, thermal relay, fuse, under-reverse phase relay, air switch
|
|
1. Nickel-chromium alloy electric wire heater
2. Heater control mode: non-contact and other periodic pulse width adjustment, SSR (solid state relay)
3. Heater power: (27) KW
|
4.5. Humidifier
|
1. External detachable boiler humidification method
2. Stainless steel armored humidifier
3. Humidifier control mode: non-contact and other periodic pulse width adjustment, SSR (solid state relay)
4. Water level control device, humidifier anti-drying device, sediment collecting device, liquid level observation window
5. Humidifier power: (18) KW
|
4.5. Waterway |
1. Automatic water supply device
2.RO membrane + activated carbon water supply filter, removable cleaning
3. High and low temperature double water level electronic level switch to prevent malfunction
4. Water shortage and air pollution over temperature protection + ultra low water level protection + water supply timeout to ensure safe operation of equipment
|
|
Located on the back of the machine room |
|
|
5.1. Ways of working | Binary cascade cooling |
|
Fully enclosed (semi-closed) low noise rotor compressor |
|
Outer fin internal threaded tube heat exchanger (also used as dehumidifier) |
|
Air-cooled: outer fin internal threaded tube heat exchanger |
|
Expansion valve + capillary |
(usedincascaderefrigeration system) |
Stainless steel brazed plate heat exchanger |
|
1. The control system automatically adjusts the optimal energy-saving condition of the chiller operation according to the test conditions.
2. The evaporator cooling capacity is switched by the control system to drive the solenoid valve
3. Compressor return air cooling circuit
|
|
R404a/R23 (Ozone depletion index is 0, R23 is used in cascade refrigeration system) |
|
|
|
Japan OYO9256P |
monitor |
OYO9256P: 5.7 inches, 640 x 480 dot matrix, TFT color LCD display
|
Operation mode |
Program mode, setting method
|
Setting method |
OYO9256P Chinese and English menu (free choice), touch screen input
|
Program capacity |
OYO9256P (touch type)
1. Program: up to 120 groups
2. Number of segments: up to 14400 segments
3. Number of cycles: maximum infinite loop
|
Predetermined area |
Temperature: adjusted according to the temperature range of the equipment
|
Resolution |
Temperature: 0.01 ° C; time: 1 min; Humidity: 0.1% RH (temperature and humidity test equipment)
|
Input |
0~5VDC analog signal
|
Communication function |
U disk interface, RS-232 interface, misoperation hardware lock LOCK, random computer communication software
|
control method |
1. Anti-integration saturation PID
2.BTC balance temperature control mode + DCC intelligent cooling capacity control + DEC intelligent electrical control (temperature test equipment)
3. BTHC balance temperature regulation and humidity control mode + DCC intelligent cooling capacity control + DEC intelligent electrical control (temperature and humidity test equipment)
|
Curverecording function |
With battery-protected RAM, it can save the set value, sampling value and sampling time of the device; the maximum recording time is 180 days (when the sampling period is 60S)
|
Accessory function |
1. Fault alarm and cause, processing prompt function
2. Power failure protection function
3. Upper and lower limit temperature protection function
4. Calendar timing function (automatic start and automatic stop operation)
5. Self-diagnosis function.
|
|
Swiss Rodriguez electronic temperature and humidity sensor (damp heat only) |
|
|
|
Solenoid valve + water level switch automatic control |
|
The back of the machine room is connected to Younik automatic pure water filtration, and the external interface directly connects the user to the sustainable water source. |
|
Resistivity ≥ 2600 Ω.cm (≥ tap water quality) |
|
|
|
1. Compressor overheat protection
2. Compressor overcurrent protection
3. Compressor high and low voltage protection
4. Compressor oil pressure protection (optional for large semi-hermetic compressors)
5. Supply temperature over temperature protection
6. Ultra high pressure relief protection
7. Air-cooled: condensing fan overheated
|
8.2. Humidification system |
1. Humidification heat pipe dry burning protection
2. Water level abnormal protection
3. Water supply overtime protection
|
|
1. Adjustable over temperature protection
2. Air conditioning channel limit over temperature protection
3. Fan motor overheat protection
|
|
1. Total power phase sequence and phase loss protection (for three-phase power supply)
2. Overload and short circuit protection
3. The cabinet is opened several times to cause the refrigeration system fault alarm protection
|
(three) configuration list
Serial number | name | Origin brand | Remarks |
1 | Controller (R232+U disk storage interface) | Japan OYO | OYO9256P |
2 | Electromagnetic switch | Taiwan Shilin or Taiwan Taian | SP-11/16/18,CU-11/16/18 |
3 | thermal relay | Taiwan Shilin or Taiwan Taian | 380V5.5-8.5A(8.5-12.5A) |
4 | Intermediate relay | Japan Omron | MY2 or MY2N-JS |
5 | Time Relay | Japan CKC | AH3-2 |
6 | Under-reverse phase relay | Swiss Jiale | DPA51CM44 |
7 | Over temperature protection | Korea RAINBOW | TS-320S |
8 | SSR | Taiwan Kaitong or Taiwan Yangming | 20A~40A |
9 | Temperature and humidity sensor (damp heat only) | Roznik | H-300 |
10 | flashlight | Chinese rainbow | 40W high temperature type |
11 | Signal indicator | Shanghai Tianyi | LA12D |
12 | Flash buzzer | Shanghai Tianyi | LA42S |
13 | Machine control transformer | Taiwan Huada | 500W |
14 | Fuseless switch | Taiwan Shilin | 380V/40A/60A/100A |
15 | power switch button | Japan CKC | 240V 5A |
16 | Emergency stop switch | Japan CKC | 240V 5A |
17 | Heater (warming and humidifying) | Taiwan Longxing | custom made |
18 | Circulation fan | TaiwanYongzhengorTaiwan Mitsukoshi | 220V90W |
19 | wind mill | Taiwan Shangyu | 9F |
20 | Liquid level switch (for constant temperature and humidity) | Hong Kong Chinatown | 300V |
21 | Pure water device (for constant temperature and humidity) | Ukrainian | Standard |
22 | Inlet water solenoid valve | Japanese SNS | 220V 1/4 |
23 | Anti-sweat line | Taiwan GOOLMAX | 24VDC50W |
24 | Multi-layer vacuum glass window | Hong Kong Qingqiang | custom made |
25 | High temperature line | China Jin Mingtai | Optional |
26 | Wire and Cable | China Jin Mingtai | Optional |
27 | compressor | France Taikun or Bitzer | Optional |
28 | Condenser | Taiwan Keweili | custom made |
29 | Condensing fan (for air-cooled) | Guo Dunli or Shimmer | 220V350mm |
30 | Water tower (for water cooling) | China Liangyan | 10~50T |
31 | Water pump (for water-cooled type) | China Kenflay | 1.5P~5P |
32 | Dry filter | Danfoss, Denmark | DCL032/053/083/085 |
33 | Expansion valve | Danfoss, Denmark | TS2 |
34 | The electromagnetic valve | Japanese Heron Palace or Kasto | 3/8 or 5/8 |
35 | Plate heat exchanger (multilayer type) | Japan Eastern Union | CB14-20HSR16 |
36 | Evapo Taiwan Keweili rator | Taiwan Zhongli | custom made |
37 | The refrigerant | DuPont | R404A/R23 |
38 | Frozen oil | British ice bear | RL32H |
39 | Oil separator | Emerson(formerly American ALCO) | Largesystemsupporting 55824/55855 |
40 | Gas Company Details Bronze Gleitlager,Bronze Sleeve BushingsandGraphite Plugged Bushingsfrom Quality China Factory
Dongguan Jiedong Test Equipment Co., Ltd. ... Dongguan Jiedong Test Equipment Co., Ltd. ... Get in touch with us