Payment Terms | T/T, Western Union |
Delivery Time | 2-4 work days |
Packaging Details | Neutral Package |
Category | medical apparatus |
Description | Power Supply |
Service | Repair service/Exchange sale |
Warranty | 60 days |
Condition | Oringal |
Purpose | imaging scan system |
Brand Name | |
Model Number | IU22 |
View Detail Information
Explore similar products
GE Logiq F8/F6 Medical Keyboard DOK V6227H 5442979
5552220-2 R1 R2 R2.5 Ultrasound Spare Parts GE Logiq P7 P9 MDC Assy
5393439 Trackball Assy With Cable 5393439-2/4 5491128 TAS4729N FLT20UWB-G1
Toshiba Xario SSA-660A Trackball Ultrasound System Accessories
Product Specification
Payment Terms | T/T, Western Union | Delivery Time | 2-4 work days |
Packaging Details | Neutral Package | Category | medical apparatus |
Description | Power Supply | Service | Repair service/Exchange sale |
Warranty | 60 days | Condition | Oringal |
Purpose | imaging scan system | Brand Name | |
Model Number | IU22 | ||
High Light | Imaging Scan System Ultrasound Spare Parts ,IU22 Power Supply Ultrasound Spare Parts |
IU22 Power Supply Ultrasound Parts Accessories Healthcare Solutions Medical Equipment Supply
iU22 Power Supply Ultrasound Parts Accessories healthcare solutions
1. Available for Exchange and Repair Service
2. Warranty: 60 days
3. Compatiable with iU22
Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ mintenance range.
Other ultrasound parts related to that we can offer:
Brand | System | Description |
iU22/iE33 | Front End Controller 453561278261/453561278266/453561464291/453561153751 | |
iU22/iE33 | excelsior motherboard 453561419431/453561382231/453561419431 | |
iU22/iE33 | Unified Motherboard 453561254492 453561360251 | |
iE33 | G Cart Channel Board 453561303332 | |
iE33 | TI board 453561167791 | |
iE33 | Front End Controller board 453561278265 | |
iE33 | PC components | |
iE33/iU22 | version G Cart power boardMP6-3L-0M 73-560-7011 453561642151/453561395402/453561395432 | |
ClearVue350 | AC/DCpower board | |
ClearVue350 | numeric keyboard | |
ClearVue350 | track board | |
CX50/CX30 | AC power board adapter 453561367414 | |
CX50 | Channel board 453561662431 | |
CX50/CX30 | power board 453561375144 | |
CX50 | control panel 453561685791 | |
CX50 | monitor | |
CX50 | systems 3.1.1 | |
CX50 | TI board 453561473251 | |
CX50 | QWERY Alphanumeric Keyboard numeric keyboard 453561364341 | |
EPIQ 5 | ACQ Acquisition Module board 453561734844/ 453561704246 | |
EPIQ 5 | channel board 453561704244 version A | |
Affiniti 50G | mother board 453561736531B | |
Affiniti 50 | ACB Assy acquisition control board | |
Affiniti 70 | ACB Assy acquisition control board | |
ATL | HDI-3500/HDI-5000 | AIFOM ASSY 7500-1413-03A |
ATL | HDI-3500/HDI-5000 | Module Assy 3500-3079-01 |
ATL | HDI-3500/HDI-5000 | power board 2500-1342-02A |
ATL | HDI-3500/HDI-5000 | SPM 3500-2988 |
ATL | HDI-3500/HDI-5000 | PIM board 7500-1917-02c |
Knowledge Point
Color Doppler flow imaging
Color Doppler flow imaging system can simultaneously display B-type image and Doppler blood flow data (blood flow direction, flow velocity, flow dispersion) of dual ultrasound scanning system. Color power angio(CPA) detected the backscattered energy of blood cells in the blood flow, which did not distinguish the flow direction, and had nothing to do with the angle θ (the angle between the direction of sound wave and the direction of blood flow). CPA can improve the sensitivity of blood flow detection, especially suitable for displaying low-speed blood flow of small vessels, but can not show the direction of blood flow.
Common failures of color Doppler ultrasound
1. Control panel failure
2. System software, application software failure
3. Back end failure
4. Power failure (Main power supply, Low-voltage power supply, High-voltage power supply)
5. Transducer Probe failure
6. Front-end failure (Interface board, Transmitter, Receiver, Control, VIDEO, Front-end connection)
7. Display failure (Display, Workstation, Touch screen)
8. Failure caused by external environment
Front end troubleshooting summary
1. The front and back connection processing board has multiple functions
2. TR Board, image processing
3. Probe interface board failure
4. The back end board is responsible for the whole machine
5. The video board is responsible for image problems
Company Details
Business Type:
Distributor/Wholesaler,Exporter,Trading Company,Seller
Year Established:
2014
Total Annual:
5,000,000-10,000,000
Employee Number:
50~60
Ecer Certification:
Verified Supplier
Rongtao Medical was established in 2013, we have been focusing on providing after-sales service for medical equipment for the last ten years, especially in ultrasound. We have been continuously improving our technical capabilities, breaking through technical problems, innovating service models to ex... Rongtao Medical was established in 2013, we have been focusing on providing after-sales service for medical equipment for the last ten years, especially in ultrasound. We have been continuously improving our technical capabilities, breaking through technical problems, innovating service models to ex...
Get in touch with us
Leave a Message, we will call you back quickly!