Payment Terms | T/T, Western Union, L/C |
Supply Ability | 5000pcs per month |
Delivery Time | 7-15days |
Packaging Details | Carton box |
Type | Online UPS 220V |
Phase | 1:1 phase online ups |
Protection | Short circuit, over voltage/load/current, undervoltage, etc. |
IGBT | Fairchildsemi/Infineon |
Size(MM) | 330*703*755 |
Net Weight(KGS) | 80 |
Optional SNMP | Power management from SNMP manager and Web browser |
Brand Name | CPSY |
Model Number | GP1103K |
Certification | CE,TLC,ISO9001, OHSAS18001,ISO14001 |
Place of Origin | China |
View Detail Information
Explore similar products
kvs Oms Low Frequency UPS Double Conversion Ups DSP Technology Remote Management
15kva/12kw Low Frequency UPS Three Phase In/Out With Isolate Transformer
Maxima Ups 3 Phase 384vdc , 50hz 60hz Circuit Board Pure Sine Wave Online Ups
160KVA/128KW Low Frequency UPS Professional Global Power Solution Company No
Product Specification
Payment Terms | T/T, Western Union, L/C | Supply Ability | 5000pcs per month |
Delivery Time | 7-15days | Packaging Details | Carton box |
Type | Online UPS 220V | Phase | 1:1 phase online ups |
Protection | Short circuit, over voltage/load/current, undervoltage, etc. | IGBT | Fairchildsemi/Infineon |
Size(MM) | 330*703*755 | Net Weight(KGS) | 80 |
Optional SNMP | Power management from SNMP manager and Web browser | Brand Name | CPSY |
Model Number | GP1103K | Certification | CE,TLC,ISO9001, OHSAS18001,ISO14001 |
Place of Origin | China | ||
High Light | three phase ups ,sine wave online ups |
3kva price online ups with isolation transformer green power online ups 220V 230V 240V
Low Frequency Online UPS
Technical Specifications
True Online Dual Conversion UPS
Built-in Galvanic Isolation Transformer
Field Proven Rugged design for tough power conditions
State of the art technology
IGBT based SPWM technology
Excellent warranty & post warranty support
Wide range of products from 1KVA to 300KVA
Wide input range
Compact size
High performance/High efficient design
Near unity input power factor
Excellent Voltage Regulation and Transient response
User friendly comprehensive LCD display and mimic diagram
Supports all types of batteries
Extended Run Time
Generator Compatible
After Sale support available in major cities across the country
Optional Intelligent Computer Interface and SNMP
Optional Auto Bypass (Static bypass)
Optional Parallel redundancy / Static redundancy
Applications
Office Automation
Data Centres
Building Management
Education Institutes
Telecommunication Centres
Satellite Earth Station
CNC Machines
Banking
Defence
R and D Centres
Bio-medical Equipments
Lift and Elevators
Industrial Instrumentation
Machine Tools
Security and surveillance equipments
Colour Lab Equipment
Photo Copying Machines
Printers and Plotters
Embroidery Machines
Medical Equipments
Diagnostic/Lab Equipments
Ultra Sonic Sonography Machines
ATM Centres
Technical Parameters:
Model | GP1103K | GP1106K | GP1110K | GP1115K | GP1120K | |
Capacity | 3KVA/2.4KW | 6KVA/4.8KW | 10KVA/8KW | 15KVA/12KW | 20KVA/16KW | |
INPUT | ||||||
Input Voltage range | 165VAC~275VAC | |||||
Bypass Voltage Range (Vac) | 220±15% | |||||
Mains frequency range (Hz) | 45~55Hz | |||||
Bypass frequency range (Hz) | 47~53/57~63(Hz) | |||||
Phase | Single-phase three-wire | |||||
Bypass lock function | The generator frequency is locked in 47 ~ 53Hz | |||||
Battery voltage (Vdc) | 192V(220V) | |||||
OUTPUT | ||||||
Voltage range (Vdc) | 220 ± 1%, isolated transformer output | |||||
Frequency (Hz) | 50 ± 0.5% (battery mode) | |||||
Waveform | Sine wave,THD <3% (linear load) THD <5% (non-linear load) | |||||
Switch time | ≤ 0ms (2ms between bypass and inverter) | |||||
Overload capacity | (1) 100% <load ≤110%, long-term load; (2) 110% <load ≤ 130%, 10 minutes Bypass; (3) 130% <load ≤150%, 30S bypass (4) load ≥150% 10S bypass |
|||||
output method | Wiring row | |||||
Peak coefficient | 3:01 | |||||
OTHER CHARACTERISTIC | ||||||
Display function | LCD liquid crystal display input voltage, output voltage, load size, battery voltage and so on | |||||
Alarm function | Overload, mains abnormality, battery undervoltage, battery overvoltage, UPS fault | |||||
Protective function | Battery undervoltage, overload, overtemperature, short circuit, output overvoltage, output undervoltage | |||||
Communication function (optional) | Through RS232, support power monitoring software, suitable for a variety of computer operating platform, optional SNMP network adapter to achieve power management network | |||||
Fault dry contact | Interface can be up to 2A current, easy to use, safe | |||||
Standby time | Can be configured arbitrarily | |||||
Battery efficiency | > 85% | |||||
Altitude | Meet the provisions of GB / T 7260.3-2003 | |||||
Standard | IEC 61000-4-5 Protection surge;IEC62040-1 EMC/EMI, IEC62040-1 Safety | |||||
PHYSICAL | ||||||
Dimension,D×W×H (mm) | 330*703*755 | 430*902*934 | ||||
Net Weight(KGS) | 80 | 93 | 111 | 171 | 198 | |
ENVIRONMENT | ||||||
Operating Temperature | "-10~40℃ continuous running; 45℃ derating to 85% with linear load | |||||
Humidity | 0~90% (Non-Condensing) | |||||
Noise level | less than 55dB @ 1 Meter (YD/T1095-2008) | |||||
MAINTENANCE | ||||||
Modbus RS-232/RS485 | Support Windows 2000/2003/XP/Vista/2008/7/8,Linux and MAC | |||||
Optional SNMP | Power management from SNMP manager and Web browser |
Online ups advantage:
UPS Products Detection/Injection:
A. Pre-Production -------Board Detective
B. Production -------------The detection of the parameters, waveform, voltage, current and so on.
C. Ageing detection------stability, work status, charging situation and so on.
D. Appearance and function detection before packing.
After-sales service:
Customers Provide proper instructions to the technical support department through proper procedures to explain the cause and condition of any damage to the product. The detail procedure of warranty as belowing:
1. Send Photo or video of damage products with Serial number label to shangyu, will reply you in 12 hours.
2. The technical engineers will send the Detection table to you for feedback in 24hours.
3. Fault handling and suggestion table will be send to you in 48hours after technical department get the Detection table.
4. We will send you the spare parts by free if the problems caused by us during warranty period.If it is the men-made problems,we also send the spare parts,but you should pay.
5. Other problems can be solved according to the Fault handling and suggestion table.
If any misunderstand, call us immediately.
Company Details
Business Type:
Manufacturer,Trading Company
Year Established:
2011
Total Annual:
15000000-20000000
Employee Number:
100~200
Ecer Certification:
Active Member
Shangyu (Shenzhen) Technology Co. Ltd A Professional Manufacturer of Uninterruptible Power Supply Shangyu (Shenzhen) Technology Co. Ltd is a professional manufacturer of uninterruptible power supplies. We are located in Shenzhen and have a registered capital of $2.3 million and ... Shangyu (Shenzhen) Technology Co. Ltd A Professional Manufacturer of Uninterruptible Power Supply Shangyu (Shenzhen) Technology Co. Ltd is a professional manufacturer of uninterruptible power supplies. We are located in Shenzhen and have a registered capital of $2.3 million and ...
Get in touch with us
Leave a Message, we will call you back quickly!