Payment Terms | T/T |
Supply Ability | 100 units per month |
Delivery Time | 15 days |
Packaging Details | Plywood wooden box |
Product Name | Water-Cooled Scroll Chiller |
Compressor | Scroll Compressor |
Evaporator | Shell and Tube |
Condenser | Shell and Tube |
Controller | Microprocessor |
Noise Level | ≤75dB(A) |
Refrigerant | R22/R407C/R410A |
Protection | High/Low Pressure, Overload, Overheat, etc. |
Warranty | 1 Year |
Brand Name | JIALIS |
Model Number | JLSK-60HP |
Certification | CE/ISO9001 |
Place of Origin | Dongguan China |
View Detail Information
Explore similar products
Low Noise Water Cooled Scroll Chiller For Injection Molding Bottle Blowing
JLSK-30HP Scroll Water Cooled Chiller For Injection Moulding Machine Pharmaceuti
JLSK-12HP Water Cooled Scroll Chiller , Cooling Chiller Machine 220V 380V 50Hz
JLSK-75HP Water Cooled Scroll Chiller For Robots 3D Printing CE Certified
Product Specification
Payment Terms | T/T | Supply Ability | 100 units per month |
Delivery Time | 15 days | Packaging Details | Plywood wooden box |
Product Name | Water-Cooled Scroll Chiller | Compressor | Scroll Compressor |
Evaporator | Shell and Tube | Condenser | Shell and Tube |
Controller | Microprocessor | Noise Level | ≤75dB(A) |
Refrigerant | R22/R407C/R410A | Protection | High/Low Pressure, Overload, Overheat, etc. |
Warranty | 1 Year | Brand Name | JIALIS |
Model Number | JLSK-60HP | Certification | CE/ISO9001 |
Place of Origin | Dongguan China | ||
High Light | Electrophoresis Industrial Water Chiller Machine ,Electroplating Industrial Water Chiller Machine |
JLSK-60HP Water-Cooled Scroll Chiller Electroplating, Electrophoresis, Hydraulic Pressure, Mold Cooling
Product Description:
Water-cooled open-type chiller is a cooling device used in refrigeration and air-conditioning systems. Its working principle is to use a compressor to compress the refrigerant into a high-temperature and high-pressure gas, and then cool it into a low-temperature and low-pressure gas through a heat exchanger, and then pass through After the expansion valve is adjusted, it enters the evaporator to make it absorb the heat in the air and cool it down, and finally passes through the compressor to and fro to form a refrigeration cycle.
Different from closed-type chillers, water-cooled open-type chillers use public water sources (such as tap water) in the cooling process, and circulate water through cooling towers and cooling water pipelines to cool the refrigerant, thereby achieving cooling effects. At the same time, the cooling water of the water-cooled open chiller will be sprayed on the cooling tower during the cooling process to form water mist, so it is called "open type".
Production Features:
Water-cooled open chiller is a cooling equipment used in industrial and commercial air-conditioning systems, and its features are as follows:
1.High efficiency and energy saving: The water-cooled open chiller adopts high-efficiency compressors and heat exchangers, which can quickly cool down during operation, improve the efficiency of the air conditioning system, and reduce energy consumption costs.
2.High reliability: The design and manufacture of the water-cooled open chiller adopts proven technology and materials, which has high reliability and can maintain stable performance during long-term operation.
3.Space-saving: The water-cooled open chiller is small in size and takes up less space, so it can be used in places with limited space.
4.Easy maintenance: The water-cooled open chiller has a simple structure, easy maintenance, and low maintenance costs.
5.Environmental protection and energy saving: The water-cooled open chiller uses environmentally friendly refrigerants, which will not pollute the environment, and at the same time can reduce energy consumption and achieve the purpose of energy saving and emission reduction.
6.Wide range of applications: Water-cooled open chillers are suitable for air-conditioning systems of various scales and can meet the needs of different applications.
Working Principle:
The water-cooled scroll chiller is a chiller that uses water cooling. It adopts scroll compressor technology, which can generate high pressure in a small space, making the cooling effect more excellent. The water-cooled scroll chiller is mainly composed of a compressor, a condenser, an expansion valve and an evaporator. Its working principle is as follows:
1.Compressor: The water-cooled scroll chiller uses a scroll compressor to compress low-temperature and low-pressure refrigerant gas into high-temperature and high-pressure gas.
2.Condenser: The high-temperature and high-pressure gas exchanges heat with the external water through the condenser, so that the refrigerant gas is cooled and condensed into a high-pressure liquid.
3.Expansion valve: The high-pressure liquid is depressurized through the expansion valve, becomes a low-temperature low-pressure liquid, and then enters the evaporator.
4.Evaporator: The low-temperature and low-pressure liquid exchanges heat with the outside air through the evaporator, thereby absorbing the heat in the air and evaporating the refrigerant liquid into a low-temperature and low-pressure gas.
5.Cycle: Low-temperature and low-pressure gas enters the compressor to start a new refrigeration cycle.
Compared with air-cooled chillers, water-cooled scroll chillers use water cooling, so a water source is required. However, compared with air, water is less compressible, so the cooling effect of water-cooled scroll chiller is more stable, the noise is lower, and it is also more environmentally friendly. In addition, scroll compressors are more efficient than traditional reciprocating compressors, and can generate high pressure in a small space, resulting in better cooling effects.
Techinical Parameters:
Model | JLSK-5HP | JLSK-10HP | JLSK-15HP | JLSK-20HP | JLSK-25HP | JLSK-30HP | JLSK-40HP | JLSK-50HP | JLSK-60HP | ||
Cooling capacity | KW | 15.5 | 31 | 46.5 | 62 | 77.5 | 93 | 124 | 155 | 186 | |
Kcal/h | 13,750 | 27500 | 41,250 | 55,000 | 68,750 | 82,500 | 110,000 | 137,500 | 165,000 | ||
Temperature range | 5℃~35℃(Below 0℃ can be customized) | ||||||||||
Power supply | 3N-380V/415V 50HZ/60HZ | ||||||||||
Total power | KW | 4.1 | 8.1 | 12.4 | 16.5 | 20.2 | 24.6 | 32.2 | 40.3 | 48.5 | |
Chilled water | m³/h | 2.6 | 5.5 | 8.2 | 10.8 | 13.6 | 16 | 21.2 | 26.5 | 31.8 | |
Cooling water | m³/h | 3.2 | 6.8 | 10.3 | 13.9 | 17.2 | 20.5 | 27.3 | 34.2 | 40.8 | |
Compressor | Type | Fully enclosed scroll/piston | |||||||||
Start method | Y-△启动 | ||||||||||
Output Power | KW | 3.8 | 7.5 | 11.3 | 15 | 18.8 | 22.5 | 30 | 37.5 | 45.5 | |
Refrigerant | Type | R-22/R407C/R410A | |||||||||
Control method | Temperature Sensing External Pressure Equalizing Expansion Valve | ||||||||||
Filling volume | KG | 2.5 | 5 | 7.5 | 10.5 | 12.5 | 15 | 20.2 | 25 | 30 | |
Evaporator | Type | shell and tube | |||||||||
Diameter | ㏑ | G1.5″ | G2″ | G2.5″ | G3″ | ||||||
Condenser | Type | shell and tube | |||||||||
Diameter | ㏑ | G1.5″ | G2″ | G2.5″ | G3″ | ||||||
Protective device | High and low voltage switch, antifreeze protection, soluble plug/safety valve, overload protection device, coil overheat protector, automatic temperature protection switch, etc. | ||||||||||
Dimensions | L | mm | 950 | 1260 | 1600 | 1600 | 1850 | 1850 | 2250 | 2250 | 2600 |
W | mm | 500 | 650 | 650 | 700 | 700 | 700 | 850 | 850 | 850 | |
H | mm | 1220 | 1220 | 1300 | 1300 | 1300 | 1360 | 1420 | 1420 | 1420 | |
Unit weight | KG | 150 | 280 | 460 | 520 | 600 | 850 | 1050 | 1380 | 1550 |
Application Industry:
Water-cooled open chillers are widely used in refrigeration and air-conditioning systems in various industries, including but not limited to the following:
1.Industrial refrigeration: Water-cooled open chillers are widely used in the field of industrial refrigeration, such as cold storage, pharmaceuticals, chemicals, plastics, rubber, electronics, metallurgy, food, beverages and other industries.
2.Commercial air conditioning: Commercial buildings such as large shopping malls, office buildings, hotels, hospitals, etc. need to use water-cooled open chillers to maintain indoor temperature.
3.Transportation: Water-cooled open chillers are also widely used in the field of transportation, such as the cooling system of high-speed rail, aircraft, ships and other vehicles.
4.Energy field: Water-cooled open chillers are also widely used in the energy field, such as nuclear power plants, wind power generation, solar power generation and other fields.
Automotive Manufacturing Chemical Engineering Electronics Industry Electroplating Industry
Injection Molding Industry Pharmaceutical Industry Plastic Packaging Industry Printing Industry
Upport and Services:
Air Cooled Chiller technical support and service includes:
1. 24/7 customer support
2. Remote guidance installation and maintenance
3. Remote Diagnostics and Troubleshooting
4. Phone/Email Advice and Guidance
5. User friendly documentation and manuals
6. Software Updates and Upgrades
7. Cost price of spare parts and consumables
Packing and Shipping:
Air-cooled chillers are packaged and shipped in standard plywood wooden boxes. All components are secured and protected with a film, and the unit is then placed on a pallet for easy transport. And affix the shipping mark information label on the wooden box to ensure correct delivery.
Product Maintenance:
Water-cooled scroll chiller is an important refrigeration equipment. In order to ensure its normal operation and prolong its service life, regular maintenance is required. The following are the matters needing attention in the maintenance of the water-cooled scroll chiller:
1.Regular cleaning: The water-cooled scroll chiller needs to be cleaned regularly, including cleaning the condenser and evaporator and other components to ensure that its surface is clean and free from dirt or dust, so as to ensure the cooling effect.
2.Clean the filter screen regularly: The filter screen needs to be cleaned regularly to avoid dust and dirt from clogging the filter screen and affecting the cooling effect.
3.Regularly replace the refrigerant: The refrigerant needs to be replaced regularly to ensure its cooling effect.
4.Regular inspection of pipes: Regular inspection of pipes is required to ensure that they are not leaking or damaged, so as to avoid refrigerant leakage and affect cooling effect and safety.
5.Regular inspection of electrical components: Regular inspection of electrical components is required to ensure good electrical connections and normal operation of electrical equipment to avoid safety accidents caused by electrical failures.
6.Regular inspection of scroll compressors: Scroll compressors need to be inspected regularly to ensure their normal operation and avoid safety accidents caused by compressor failures.
7.Regularly check the surrounding environment of the unit: It is necessary to regularly check the surrounding environment of the unit to ensure that there are no sundries or obstacles to avoid affecting the normal operation of the unit.
In short, the maintenance of the water-cooled scroll chiller is very important. It needs regular cleaning, replacement of refrigerant, inspection of pipelines, electrical components and scroll compressors, etc. to ensure its normal operation and safety. At the same time, it is necessary to pay attention to regular maintenance, and do not overuse or overload the operation to avoid damage to the equipment.
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Agent,Exporter,Trading Company,Seller
Year Established:
2008
Total Annual:
10 million-15 million
Employee Number:
200~300
Ecer Certification:
Verified Supplier
Dongguan Jialisheng Refrigeration Equipment Co., Ltd. is a modern enterprise focusing on the research, development, production, sales and service of industrial temperature control equipment. Since its establishment, the company has been focusing on the field of industrial temperature control. With a... Dongguan Jialisheng Refrigeration Equipment Co., Ltd. is a modern enterprise focusing on the research, development, production, sales and service of industrial temperature control equipment. Since its establishment, the company has been focusing on the field of industrial temperature control. With a...