Product Name | Cross Flow Cooling Tower |
Flow | 100m3/h-8000m3/h |
Machine Parts | Aluminum Alloy Fan/Special Motor/PVC Filler/Drain Tray/Glass Fiber Reinforced Plastic Components/Steel Structural Parts |
Type | Low Temperature Type/Standard Type/Medium Temperature Type/High Temperature Type |
Casing Material | Stainless Steel |
Application | Water Treatment Equipment |
Model Number | HLT Series |
Certification | CTI/ISO9001:2008 |
Place of Origin | Jiangsu, China |
View Detail Information
Explore similar products
CTI Institute Square Combined Crossflow Open Circuit Cooling Tower
CTI Institute Cross Flow Natural Draft Open Loop Cooling Tower
Steel Structure FRP Counterflow Open Circuit Cooling Tower High Efficiency
Package Type Industrial Counter Flow Open Loop Cooling Tower
Product Specification
Product Name | Cross Flow Cooling Tower | Flow | 100m3/h-8000m3/h |
Machine Parts | Aluminum Alloy Fan/Special Motor/PVC Filler/Drain Tray/Glass Fiber Reinforced Plastic Components/Steel Structural Parts | Type | Low Temperature Type/Standard Type/Medium Temperature Type/High Temperature Type |
Casing Material | Stainless Steel | Application | Water Treatment Equipment |
Model Number | HLT Series | Certification | CTI/ISO9001:2008 |
Place of Origin | Jiangsu, China | ||
High Light | Induced Draft Open Circuit Cooling Tower ,Stainless Steel Open Circuit Cooling Tower ,Cross Flow Open Circuit Cooling Tower |
Stainless Steel Induced Draft Cross Flow Cooling Tower Open Circuit Cooling Tower
Cooling Tower Quality Control:
Under standard working conditions, the circulating cooling water volume, cooling effect and operating noise are ensured. During the manufacturing process of the cooling tower, each process of the product is strictly controlled in accordance with the ISO9001 quality system assurance model standard to ensure its operating effect and ensure that unqualified products do not flow into the next process. Before the cooling tower leaves the factory, a trial run is carried out to detect its noise and wind speed, so that the various indicators of the product meet the user's requirements.
Cooling Tower Specification:
Model | Volume | Temp Difference ℃ | Dimension | Fan | User-made Pipe Valve | Noise dB(A) |
Weight kg |
Weight kg | ||||||||||
28℃ |
27℃ | L×W×H | Air Volume ( Ten Thousand) m3/h |
Diameter cm |
Power kw |
Trans mission |
Number |
Water inlet pipe mm |
Water distribution mm |
Water outlet mm |
Water supply mm |
Overflow pipe mm |
Drainage outlet mm | |||||
10 |
10 |
12 |
5 | 1700×850×1250 | 0.60 | 500 | 0.37 | Direct |
1 |
40 |
32x2 |
65 |
25 |
30 |
30 |
∠50 | 200 | 450 |
6 | 1700x850×1500 | 0.72 | 600 | 0.75 | 210 | 460 | ||||||||||||
10 | 1700x850×1750 | 1.05 | 700 | 0.75 | 220 | 470 | ||||||||||||
25 | 1700×850×2000 | 1.80 | 700 | 1.5 | 230 | 480 | ||||||||||||
15 |
15 |
18 |
5 | 1800x950x1500 | 0.72 | 600 | 0.55 | Direct |
1 |
50 |
40x2 |
65 |
25 |
30 |
30 |
∠50 | 230 | 530 |
6 | 1800x950×1750 | 1.05 | 700 | 0.75 | 240 | 540 | ||||||||||||
10 | 1800×950x2000 | 1.80 | 700 | 1.10 | 260 | 560 | ||||||||||||
25 | 1800×950×2250 | 2.70 | 800 | 1.5 | 280 | 580 | ||||||||||||
20 |
20 |
25 |
5 | 1900×1150x1750 | 1.05 | 700 | 0.75 | Direct |
1 |
65 |
50×2 |
80 |
25 |
40 |
30 |
∠50 | 320 | 870 |
6 | 1900x1150×2000 | 1.25 | 800 | 0.75 | 340 | 800 | ||||||||||||
10 | 1900x1150×2250 | 1.8 | 800 | 1.10 | 360 | 910 | ||||||||||||
25 | 1900×1150×2500 | 3.2 | 800 | 1.5 | 380 | 930 | ||||||||||||
30 |
30 |
a5 |
5 | 2100x1150×2000 | 1.8 | 800 | 1.10 | Direct |
1 |
65 |
50x2 |
80 |
25 |
40 |
40 |
∠50 | 350 | 950 |
6 | 2100x1250×2250 | 2.2 | 900 | 1.10 | 380 | 980 | ||||||||||||
10 | 2100×1250×2500 | 3.3 | 900 | 1.5 | 400 | 1000 | ||||||||||||
25 | 2100×1250×2700 | 4.4 | 1000 | 2.2 | 450 | 1050 | ||||||||||||
50 |
50 |
55 |
5 | 2800x1450×2250 | 3.3 | 1000 | 1.1 | Direct |
1 |
80 |
65×2 |
100 |
40 |
50 |
50 |
∠50 | 750 | 1450 |
6 | 2800x1450x2500 | 3.8 | 1200 | 1.5 | 760 | 1510 | ||||||||||||
10 | 2800x1450×2750 | 4.8 | 1200 | 2.2 | 820 | 1600 | ||||||||||||
25 | 2800×1450×2900 | 6.5 | 1200 | 2.2 | 900 | 1700 |
Model | Volume | Temp Difference℃ | Dimension | Fan | User-made Pipe Valve | Noise dB(A) |
Weight kg |
Weight kg |
||||||||||
28℃ | 27℃ | L×W×H |
Air Volume ( Ten Thousand) m3/h |
Diameter cm |
Power kw |
Trans mission |
Number |
Water inlet pipe mm |
Water distribution mm |
Water outlet mm |
Water supply mm |
Overflow pipe mm |
Drainage outlet mm |
|||||
B0 |
80 |
90 |
5 | 3500×1700×3000 | 5.4 | 1200 | 2.2 | Direct |
1 |
100 |
80×2 |
125 |
40 |
50 |
50 |
∠51 | 890 | 1900 |
6 | 3500×1700x3200 | 6.2 | 1500 | 3.0 | 1000 | 2100 | ||||||||||||
10 | 3500×1700×3600 | 6.5 | 1500 | 3.0 | 1300 | 2400 | ||||||||||||
25 | 3500×1700×4100 | 7.2 | 1500 | 4.0 | 1500 | 2600 | ||||||||||||
100 |
100 |
115 |
5 | 3800×2100x3000 | 6,5 | 1500 | 3.0 | Direct |
1 |
125 |
100x2 |
150 |
40 |
50 |
50 |
∠51 | 1050 | 2550 |
6 | 3800×2100×3100 | 6.8 | 1800 | 3.0 | 1200 | 2600 | ||||||||||||
10 | 3800×2100×3600 | 7.5 | 1800 | 4.0 | 1500 | 2750 | ||||||||||||
25 | 4000×2300×4100 | 10.5 | 2000 | 5.5 | 1800 | 2950 | ||||||||||||
125 |
125 |
140 |
5 | 3800×2400×3000 | 7.2 | 1500 | 3.0 | Direct |
1 |
125 |
100×2 |
150 |
40 |
50 |
50 |
∠52 | 1300 | 2650 |
6 | 3800×2400×3100 | 9.7 | 1800 | 4.0 | 1400 | 2700 | ||||||||||||
10 | 3800×2400×3600 | 10.5 | 1800 | 4.0 | 1600 | 2950 | ||||||||||||
25 | 4000x240084100 | 13.6 | 2000 | 5.5 | 2000 | 3350 | ||||||||||||
150 |
150 |
170 |
5 | 4000×2700×3000 | 8.5 | 1800 | 4.0 | Direct |
1 |
150 |
125×2 |
200 |
40 |
50 |
50 |
∠52 | 1400 | 2850 |
6 | 4000×2700×3100 | 9.7 | 2000 | 4.0 | 1650 | 3100 | ||||||||||||
10 | 4200×2700×3600 | 13.6 | 2000 | 5.5 | 2000 | 3450 | ||||||||||||
25 | 4400×2700×4100 | 16.0 | 2400 | 7.5 | 2400 | 4150 | ||||||||||||
175 |
175 |
180 |
5 | 4000×2800×3000 | 9.0 | 1800 | 4.0 |
Direct Reduce |
1 |
150 |
125×2 |
200 |
40 |
50 |
50 |
∠50 | 1800 | 3400 |
6 | 4200×2800x3100 | 9.8 | 2000 | 5.5 | 1900 | 3550 | ||||||||||||
10 | 4200×2800×3600 | 14.0 | 2000 | 5.5 | 2400 | 3900 | ||||||||||||
25 | 4400×2800×4100 | 16.0 | 2400 | 7,5 | 2700 | 4300 | ||||||||||||
200 |
200 |
230 |
5 | 4200×3000×3000 | 12.2 | 2000 | 5.5 |
Direct Reduce |
1 |
200 |
125×2 |
250 |
40 |
50 |
50 |
∠53 | 1950 | 3600 |
6 | 4200x3000×3100 | 13.0 | 2000 | 5.5 | 2100 | 3780 | ||||||||||||
10 | 4400×3000×3600 | 16.2 | 2400 | 7.5 | 2400 | 4250 | ||||||||||||
25 | 4800×3200×4100 | 18.0 | 2800 | 11.0 | 2700 | 4750 | ||||||||||||
250 |
250 |
280 |
5 | 4400x3300x3000 | 13.6 | 2400 | 7.5 | Reduce |
1 |
200 |
150×2 |
250 |
40 |
65 |
65 |
∠56 | 2400 | 4470 |
6 | 4400x3300×3100 | 16.2 | 2400 | 7.5 | 2600 | 4700 | ||||||||||||
10 | 4800×3300×3600 | 18.5 | 2800 | 11.0 | 2700 | 4900 | ||||||||||||
25 | 4800x3300x4100 | 20.5 | 2800 | 11.0 | 2900 | 5300 | ||||||||||||
300 |
300 |
320 |
5 | 4800x3900x3000 | 16.2 | 2800 | 7.5 | Reduce |
1 |
250 |
150×2 |
300 |
40 |
65 |
65 |
∠56 | 2700 | 5450 |
6 | 4800x3900×3100 | 18.6 | 2800 | 11.0 | 2900 | 5650 | ||||||||||||
10 | 5000x3900x3600 | 18.6 | 3000 | 11.0 | 3000 | 5900 | ||||||||||||
25 | 5200×3900×4100 | 20.5 | 3200 | 11.0 | 3150 | 6700 | ||||||||||||
350 |
350 |
375 |
5 | 4000x5600x3000 | 18,6 | 1800 | 4.0 |
Direct Reduce |
2 |
250 |
125×4 |
200×2 |
40×2 |
50x2 |
50×2 |
∠56 | 3100 | 6900 |
6 | 4200×5600x3000 | 20.5 | 2000 | 5.5 | 3180 | 7300 | ||||||||||||
10 | 4200×5600x3600 | 23.0 | 2000 | 5.5 | 3450 | 7800 | ||||||||||||
25 | 4400x5600×4100 | 25.8 | 2400 | 7.5 | 3900 | 8500 | ||||||||||||
400 |
400 |
430 |
5 | 4200×6000×3000 | 25.0 | 2000 | 5.5 |
Direct Reduce |
2 |
200 |
125×4 |
250×2 |
40×2 |
50x2 |
50x2 |
∠59 | 3300 | 7200 |
6 | 4200×6000×3100 | 27.0 | 2000 | 5.5 | 3500 | 7500 | ||||||||||||
10 | 4400×6000×3600 | 32.0 | 2400 | 7.5 | 3950 | 7700 | ||||||||||||
25 | 4800×6400×4100 | 40.0 | 2800 | 11.0 |
4200 |
8000 |
Model | Volume |
Temp Difference ℃ |
Dimension | Fan | User-made Pipe Valve | Noise dB(A) |
Weight kg
|
Weight kg
|
||||||||||
28℃ | 27℃ | L×W×H | Air Volume ( Ten Thousand) m3/h |
Diameter cm
|
Power kw |
Trans mission
|
Number |
Water inlet pipe mm
|
Water distribution mm
|
Water outlet mm
|
Water supply mm
|
Overflow pipe mm
|
Drainage outlet mm | |||||
450 |
450 |
480 |
5 | 4000×8100×3000 | 25.0 | 1800 | 4.0 |
Direct Reduce
|
3 |
300 |
125×6 |
200x3 |
40×3 |
50×3 |
50×3 |
∠59 | 4050 | 8400 |
6 | 4000x8100x3100 | 29.0 | 1800 | 4.0 | 4200 | 8500 | ||||||||||||
10 | 4200×8100×3600 | 40.0 | 2000 | 5,5 | 4500 | 9000 | ||||||||||||
25 | 4400x8100x4100 | 48.0 | 2400 | 7.5 | 4900 | 10000 | ||||||||||||
500 |
500 |
550 |
5 | 4400×6600×3000 | 27.0 | 2400 | 7.5 | Reduce |
2 |
300 |
150×4 |
250×2 |
40×2 |
65×2 |
65×2 |
∠60 | 4100 | 8600 |
6 | 4400x6600x3100 | 32.0 | 2400 | 75 | 4250 | 9000 | ||||||||||||
10 | 4800×6600×3600 | 38.0 | 2800 | 11.0 | 4600 | 11000 | ||||||||||||
25 | 4800x6000x4100 | 52.0 | 2800 | 11.0 | 4960 | 11500 | ||||||||||||
600 |
00 |
650 |
5 | 4200×9000×3000 | 32.5 | 2000 | 5.5 |
Direct Reduce
|
3 |
350 |
125×6 |
250×3 |
40x4 |
50×3 |
50x3 |
∠61 | 4650 | 10500 |
6 | 4200x9000x3100 | 40.0 | 2000 | 5.5 | 4800 | 11000 | ||||||||||||
10 | 4400×9000×3600 | 45.5 | 2400 | 7.5 | 5300 | 12500 | ||||||||||||
25 | 4800x9600×4100 | 60.0 | 2800 | 11.0 | 5900 | 13000 | ||||||||||||
700 |
700 |
750 |
5 | 4000×11200×3000 | 40.0 | 1800 | 4.0 |
Direct Reduce
|
4 |
350 |
125x8 |
200×4 |
40×4 |
50×4 |
50×4 |
∠62 | 6100 | 13000 |
6 | 4200×11200x3100 |
45.5 |
2000 | 5.5 | 6250 | 13500 | ||||||||||||
10 | 4200×11200x3600 | 52.5 | 2000 | 5.5 | 6700 | 14000 | ||||||||||||
25 | 4400×11200×4100 | 70.0 | 2400 | 7.5 | 7600 | 15000 | ||||||||||||
800 |
800 |
860 |
5 | 4200x12000x3000 | 48.0 | 2000 | 5.5 |
Direct Reduce
|
4 |
400 |
125×8 |
250x4 |
40×4 |
50×4 |
50×4 |
∠62 | 6100 | 15100 |
6 | 4200×12000×3100 | 52.5 | 2000 | 5.5 | 6300 | 15600 | ||||||||||||
10 | 4400×12000×3600 | 72.0 | 2400 | 7.5 | 7200 | 16000 | ||||||||||||
25 | 4800x12800×4100 | 80.0 | 2800 | 11.0 | 8100 | 16900 | ||||||||||||
900 |
900 |
960 |
5 | 4000x16200x3000 | 54.0 | 1800 | 4.0 |
Direct Reduce
|
6 |
400 |
125×12 |
200×6 |
40×6 |
50×6 |
50×6 |
∠65 | 6600 | 13800 |
6 | 4000x16200x3100 | 57.5 | 2000 | 4.0 | 7000 | 16000 | ||||||||||||
10 | 4200×16200×3600 | 67.5 | 2000 | 5.5 | 8600 | 16800 | ||||||||||||
25 | 4400×16200×4100 | 90.0 | 2400 | 7.5 | 10000 | 17600 | ||||||||||||
1000 |
1000 |
1230 |
5 | 4200×15000×3100 | 62.5 | 5000 | 5.5 |
Direct Reduce
|
5 |
400 |
125×10 |
250x5 |
40×5 |
50×5 |
50x5 |
∠68 | 7600 | 16600 |
6 | 4200×15000×3100 | 65.5 | 2000 | 5.5 | 7800 | 16900 | ||||||||||||
10 | 4200×15000×3100 | 75.5 | 2400 | 7.5 | 9100 | 18900 | ||||||||||||
25 | 4800x16000x4100 | 98.0 | 2800 | 11.0 | 10100 | 20700 | ||||||||||||
1200 |
1200 |
1350 |
5 | 4200x18000×3000 | 100 | 2000 | 5.5 |
Direct Reduce
|
6 |
500 |
125×12 |
2506 |
40%6 |
50×6 |
50x6 |
∠68 | 9400 | 21000 |
6 | 4200x18000×3100 | 115 | 2000 | 5.5 | 9600 | 22000 | ||||||||||||
10 | 4400x18000x3600 | 140 | 2400 | 7.5 | 10100 | 23000 | ||||||||||||
25 | 4800×19200×4100 | 210 | 2800 | 11.0 | 12200 | 26000 | ||||||||||||
1500 |
1500 |
1650 |
5 | 4400×19800×3000 | 100 | 2400 | 7.5 | Reduce |
6 |
500 |
125x12 |
250x6 |
40x6 |
65×6 |
65x6 |
∠68 | 10100 | 23000 |
6 | 4400×19800×3100 | 115 | 2400 | 7.5 | 11500 | 25000 | ||||||||||||
10 | 4800×19800×3600 | 140 | 2800 | 11.0 | 12500 | 31000 | ||||||||||||
25 | 4800x19800×4100 | 210 | 2800 | 11.0 | 14500 | 36000 | ||||||||||||
1800 |
1800 |
1805 |
5 | 4200×27000×3000 | 100 | 2000 | 4.0 |
Direct Reduce
|
9 |
550 |
125x18 |
250x9 |
40x9 |
50x9 |
50x9 |
∠68 | 14200 | 22500 |
6 | 1200×27000×3100 | 120 | 2000 | 5.5 | 15000 | 24000 | ||||||||||||
10 | 4400×27000×3600 | 150 | 2400 | 7.5 | 17000 | 35000 | ||||||||||||
25 | 4800×28800×4100 | 240 | 2800 | 11.0 | 20000 | 56000 |
Cooling Tower Installation Requirements:
The cooling tower should be installed on a flat ground or building platform with good natural ventilation, no building obstruction at the air inlet and no heat impact. There must be no objects at 1.5-2 meters at the air inlet to ensure smooth natural wind.
The cooling tower should be installed on a horizontal foundation to ensure that the overall mass of the cooling tower is evenly stressed on the foundation pier.
Company Details
Business Type:
Exporter,Trading Company,Seller
Year Established:
2015
Total Annual:
1000000-1200000
Employee Number:
100~200
Ecer Certification:
Verified Supplier
Wuxi Weishi Industrial Complete Equipment Co., Ltd. was established in May 2015. The company is mainly engaged in environmental protection EPC general contracting (bulk material transportation/flue gas treatment/water treatment) and heavy industrial equipment trading have formed the "two wings ... Wuxi Weishi Industrial Complete Equipment Co., Ltd. was established in May 2015. The company is mainly engaged in environmental protection EPC general contracting (bulk material transportation/flue gas treatment/water treatment) and heavy industrial equipment trading have formed the "two wings ...
Get in touch with us
Leave a Message, we will call you back quickly!