AMI G3-PLC Communication Module DLMS Interface With Meter DC2-PSR4

  1. MOQ: 100
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms T/T
Supply Ability 2000 per day (based on the number of the order)
Delivery Time 30 days
Packaging Details Carton Packaging
Color Grey
Brand Willfar Information
Communication Mode G3-PLC
Application Single Phase Meter
Reference Voltage 110 ~ 240V
Relative Humidity Up to 95% non-condensing
Level of Protection IPv6
Brand Name Willfar Information Techonology Co., Ltd.
Model Number DC2-PSR4
Certification G3-PLC
Place of Origin Changsha Hunan

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Supply Ability 2000 per day (based on the number of the order)
Delivery Time 30 days Packaging Details Carton Packaging
Color Grey Brand Willfar Information
Communication Mode G3-PLC Application Single Phase Meter
Reference Voltage 110 ~ 240V Relative Humidity Up to 95% non-condensing
Level of Protection IPv6 Brand Name Willfar Information Techonology Co., Ltd.
Model Number DC2-PSR4 Certification G3-PLC
Place of Origin Changsha Hunan
High Light 4g modulegprs module

AMI G3-PLC Communication Module for Single Phase Meter Power Line DC2-PSR4

 

Company Profile


Willfar Information Technology Co., Ltd.


- Established in 2004;
- Listed on the STAR Market of the Shanghai Stock Exchange in December 2019;
- Leading supplier of meter reading (AMI) equipment and operation service;
- The first company to develop "One DCU Reading Multi-meter" solution in China;
- The first company to have large-scale application of technologies and systems like "CPU smart-card Charge and Control", "One DCU Reading Multi-meter", LoRa-based RF Communication and "District Metering Area (DMA)”

 

Introduction

 

- G3-PLC is an open power line communication module designed for smart grid communication. Its physical layer is based on OFDM modulation and complies with G3 standards.

- G3-PLC have high-speed communication, strong anti-interference ability, the communication speed is much faster than traditional PLC.

- The module has very low maintenance cost. Metering reading network operating with G3-PLC is automatically constructing, automatically addressing and route maintenance.

- It can be easily integrated in smart electric meter to provide the AMI function.

- DC2-PSR4 could be adopted to Single Phase Electric Meter.

 

 

Technical Parameter

 

Item Parameter
Reference Voltage 110 ~ 240V
Operating Voltage Range 70%-120%Un
Rated Frequency (fn) 50Hz and 60Hz
Frequency Range 47.5Hz to 63Hz
Modulation Mode OFDM (ROBO, DBPSK, DQPSK, D8PSK)
Work Frequency

CENELEC A (32kHz to 95kHz);

FCC (154kHz to 487kHz)

Anti-attenuation Capability

>78DB

(related to the operating frequency band, the impedance of the test environment and the phenotype)

Data Speed Maximum 142Kbps
Power Consumption

0.6W (static),

2.7W (Maximum working consumption)

Security 128 bit AES & AES‐CCM
Standard Support

IEEE1901.2;

IEEE802.15.4-2006;

6LoWPAN

Mechanical Dimension 65mm×45mm×16.5mm
Relative Humidity Up to 95% non-condensing
Level of Protection IPV6

 

 

Certificate

 

G3 PLC/ IEEE1901.2/IEEE802.15.4-2006/6LoWPAN/ITU G.hn/S-FSK (IEC 61334)

 

 

Features

 

1. OFDM-based PHY (BPSK, QPSK, 8PSK) makes efficient use of the spectrum

The "robust" mode of module improves communication under noisy channel conditions, operates at -15 dB SNR.

 

2. Compliant with world regulatory bodies such as CENELEC, ARIB, and FCC (10 kHz - 490 kHz)

Auto switch between CENELEC-A and FCC to adapt different scenario according to the DCU.

 

3. Standards based — pre-standard in IEEE, ITU, IEC/CENELEC and IEC/SAE

- Two layers of forward error correction (FEC) for robust data communication in harsh channels.

- Adaptive tone mapping for optimal bandwidth utilization.

- Channel estimation to select the optimal modulation scheme between neighboring nodes.

- IEEE 802.15.4-based MAC layer well suited to low data rates.

- 6LoWPAN adaptation layer to transmit IPv6 packets over powerline channels.

- Coexistence with older S-FSK (IEC 61334), and broadband IEEE P1901 and ITU G.hn standards.

- Supports IPv6 to allow Internet-based energy management systems and applications.

 

4. Security

AES-128 cryptographic engine for optimum data security.

 

5. Mesh routing protocol to determine the best path between remote network nodes

- The maximum nodes 1024

- The maximum hops 14

 

6. Over the Powerline update Firmware (OTP)

 

7. DLMS interface with meter

 

8. G3-PLC alliance Certified products

 

 

Situation

 

For Single Phase Smart Electric Meter, Data Concentrator, or other communication instruments.

 

Dimension

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Seller,Other

  • Year Established:

    2004

  • Total Annual:

    170-180 million

  • Employee Number:

    700~705

  • Ecer Certification:

    Active Member

Introduction As the first company in Hunan Province to be listed on SSE STAR Market, Willfar is the pioneer manufacturer in China that can simultaneously provide related industries with all kinds of advanced electricity, water, gas and heat metering products and meters for power distribution... Introduction As the first company in Hunan Province to be listed on SSE STAR Market, Willfar is the pioneer manufacturer in China that can simultaneously provide related industries with all kinds of advanced electricity, water, gas and heat metering products and meters for power distribution...

+ Read More

Get in touch with us

  • Reach Us
  • Willfar Information Technology Co. Ltd.
  • Wasion Industrial Park, 468 West Tongzipo Road, Yuelu District, Changsha, Hunan Province, PRC
  • https://www.willfarcommunication.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement