Payment Terms | T/T, Western Union, |
Supply Ability | 500PCS/Month |
Delivery Time | 3 Working days |
Packaging Details | 370mm*440mm*100mm |
Connected | Wired Conventional 2 zone Smoke alarm panel |
Power supply | 90-270VAC |
Back Up Battery | 1*12V sealed lead acid |
Capacity | Max 30 conventional detectors in one zone |
Types of Smoke Detectors | Photoelectric Smoke Detector |
Customized | Acceptable |
Name | 2 Zone Fire Alarm Panel |
Brand Name | XHA |
Model Number | XHA1002 |
Certification | CE |
Place of Origin | China |
View Detail Information
Explore similar products
2 Wire Conventional Fire Alarm System Wall Mount With Sound And Light Alarm
AC90-270V Fire Alarm Control Panel 4 Zone 8 Zone 16 Zone With Conventional Smoke
Wall / Ceiling Mount Conventional Fire Alarm System With Smoke / Heat Detector
2 Wire Fixed Rate Of Rise Heat Detector ROR For Conventional Safety Fire Alarm
Product Specification
Payment Terms | T/T, Western Union, | Supply Ability | 500PCS/Month |
Delivery Time | 3 Working days | Packaging Details | 370mm*440mm*100mm |
Connected | Wired Conventional 2 zone Smoke alarm panel | Power supply | 90-270VAC |
Back Up Battery | 1*12V sealed lead acid | Capacity | Max 30 conventional detectors in one zone |
Types of Smoke Detectors | Photoelectric Smoke Detector | Customized | Acceptable |
Name | 2 Zone Fire Alarm Panel | Brand Name | XHA |
Model Number | XHA1002 | Certification | CE |
Place of Origin | China | ||
High Light | Conventional 2 Zone Fire Alarm Panel ,2 Zone Fire Alarm Panel Customized ,270VAC Conventional Fire Alarm Panel |
Conventional 2 Zone Fire Alarm Panel For Fire Safety Alarm System
Introduction
Specification
Primary AC | 120VAC 50/60 Hz Power supply rating |
240VAC 50/60 Hz | |
Power supply rating | 2 Amps @ 24VDC |
Maximum Battery Charging Current | 0.90 Amps @ 26VDC |
Initiating Device Circuits Zones | Alarm Zone 2/4/8/16 |
Normal Initiating Operating Voltage | 22VDC, Maximum 26VDC, regulated |
Normal Monitor Current | <50mA |
Alarm Current | <150 mA |
Short Circuit Initiating Current (per zone) | 35mA Maximum |
Maximum Initiating Resistance (per zone) | 10 ohms |
Initiating End-of-Line Resistor | 4K7 ohms, 1/2W 5% |
Standby Detector Current (per zone) | 4mA maximum |
Maximum Detector Count (per zone) | 30 detectors |
Initiating Cabling Type | 18AWG Twisted Shielded pair (14 – 18 AWG) |
Detector Base Impedance | 430 ohms |
Fault Relay rating | 2A & 30VAC, resistive |
Alarm( Auxiliary ) Relay rating | 2A & 30VAC, resistive |
Connection Diagram
Service
1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.
5. Welcome sample order.
Company Details
Year Established:
2001
Total Annual:
4300000-7140000
Employee Number:
40~50
Ecer Certification:
Verified Supplier
We sepecializes in design and manufacture of high quality fire protection solutions for commerical, industrial and domestic applications. we have nearly 20 years experience in the field of fire protection industry.Everlasting desire for innovation drives our company's product development progres... We sepecializes in design and manufacture of high quality fire protection solutions for commerical, industrial and domestic applications. we have nearly 20 years experience in the field of fire protection industry.Everlasting desire for innovation drives our company's product development progres...
Get in touch with us
Leave a Message, we will call you back quickly!