Payment Terms | T/T, Western Union |
Supply Ability | 50000PCS/Month |
Delivery Time | 3 Working days |
Packaging Details | 60pcs/carton |
Working Voltage | DC16-30V |
Alarm Type | Audible and Visual |
Apaitplicon | Conventional Smoke Alarm System |
Installation | Wall-mounted |
Sound Level | ≥80dB |
Humidity Range | 10% to 95% non-condensing |
Operating Temperature | -10°C to 50°C |
Detection Method | Smoke and Heat |
Customized | Optional |
Brand Name | XHA |
Model Number | XHA8061 |
Certification | CE |
Place of Origin | China |
View Detail Information
Explore similar products
2 Wire Conventional Fire Alarm System Wall Mount With Sound And Light Alarm
AC90-270V Fire Alarm Control Panel 4 Zone 8 Zone 16 Zone With Conventional Smoke
Wall / Ceiling Mount Conventional Fire Alarm System With Smoke / Heat Detector
2 Wire Fixed Rate Of Rise Heat Detector ROR For Conventional Safety Fire Alarm
Product Specification
Payment Terms | T/T, Western Union | Supply Ability | 50000PCS/Month |
Delivery Time | 3 Working days | Packaging Details | 60pcs/carton |
Working Voltage | DC16-30V | Alarm Type | Audible and Visual |
Apaitplicon | Conventional Smoke Alarm System | Installation | Wall-mounted |
Sound Level | ≥80dB | Humidity Range | 10% to 95% non-condensing |
Operating Temperature | -10°C to 50°C | Detection Method | Smoke and Heat |
Customized | Optional | Brand Name | XHA |
Model Number | XHA8061 | Certification | CE |
Place of Origin | China | ||
High Light | OEM Conventional Fire Alarm System ,ODM Conventional Fire Alarm System ,80dB Audible And Visual Alarm |
80dB Minimum Alarm Sound Audible-Visual Device For Conventional Fire Alarm System
Introduction
A sounder-flasher, also known as a combination sounder-strobe or audible-visual device is a type of fire alarm notification appliance that combines both audible and visual signaling capabilities. Here's a more detailed introduction to sounder-flashers:
Audible Signaling:
The sounder component of the device is responsible for producing an audible alarm, typically in the form of a siren, horn, or other loud sound.
The audible signal is designed to alert building occupants of the emergency and prompt them to evacuate the premises.
The volume and tone of the sounder are often adjustable to ensure the alarm can be heard clearly, even in noisy environments.
Visual Signaling:
The flasher or strobe component of the device is responsible for providing a visual alarm signal.
The strobe light, which typically flashes at a rate of 1-3 Hz, is intended to attract the attention of building occupants, particularly those who may have difficulty hearing the audible alarm.
The visual signal can be especially important for individuals who are hard of hearing or deaf, as it provides a supplementary means of alerting them to the emergency.
Integrated Design:
Sounder-flashers combine the audible and visual alarm capabilities into a single, integrated device.
This design helps to streamline the installation process and ensures that both audible and visual signals are consistently placed throughout the building.
Placement and Coverage:
Sounder-flashers are strategically placed throughout a building, often near exits, stairwells, and other common areas, to ensure adequate coverage and visibility.
The placement and quantity of sounder-flashers are typically determined by local fire codes and regulations to meet the specific needs of the building and its occupants.
Power Supply:
Sounder-flashers are typically connected to the building's fire alarm system, which provides the necessary power and control for their operation.
Features
The Sound Strobe of notification appliances offers a wide range of Sound/strobes, for wall and ceiling applications, indoors. They are designed to be used in 24 volt DC systems.
Key Specifications/Special Features
DC16-30V Powered
Long life of Strobe:Minimum 40000 times
Strobe flash rate: 1 flash per second
Loud alarm sound: Minimum 80dB
Suitable for the majority of conventional fire alarm systems
Product range
Conventional Fire Alarm System
Addressable fire alarm system
Gas Extinguishing control system
Beam Detector
4 wire smoke detectors with relay output.
2 wire Conventional smoke and heat detectors
Explosion-proof flame detector for fire alarm system
Standalone smoke detectors and combustable gas detector
Service
1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.
5. Welcome sample order.
Company Details
Year Established:
2001
Total Annual:
4300000-7140000
Employee Number:
40~50
Ecer Certification:
Verified Supplier
We sepecializes in design and manufacture of high quality fire protection solutions for commerical, industrial and domestic applications. we have nearly 20 years experience in the field of fire protection industry.Everlasting desire for innovation drives our company's product development progres... We sepecializes in design and manufacture of high quality fire protection solutions for commerical, industrial and domestic applications. we have nearly 20 years experience in the field of fire protection industry.Everlasting desire for innovation drives our company's product development progres...
Get in touch with us
Leave a Message, we will call you back quickly!