China factories

China factory - Shenzhen Xinhe'an Technology Co., Ltd.

Shenzhen Xinhe'an Technology Co., Ltd.

  • China,Shenzhen ,Guangdong
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China OEM ODM Conventional Fire Alarm System Minimum 80dB Audible And Visual Alarm
China OEM ODM Conventional Fire Alarm System Minimum 80dB Audible And Visual Alarm

  1. China OEM ODM Conventional Fire Alarm System Minimum 80dB Audible And Visual Alarm
  2. China OEM ODM Conventional Fire Alarm System Minimum 80dB Audible And Visual Alarm

OEM ODM Conventional Fire Alarm System Minimum 80dB Audible And Visual Alarm

  1. MOQ: 1
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms T/T, Western Union
Supply Ability 50000PCS/Month
Delivery Time 3 Working days
Packaging Details 60pcs/carton
Working Voltage DC16-30V
Alarm Type Audible and Visual
Apaitplicon Conventional Smoke Alarm System
Installation Wall-mounted
Sound Level ≥80dB
Humidity Range 10% to 95% non-condensing
Operating Temperature -10°C to 50°C
Detection Method Smoke and Heat
Customized Optional
Brand Name XHA
Model Number XHA8061
Certification CE
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, Western Union Supply Ability 50000PCS/Month
Delivery Time 3 Working days Packaging Details 60pcs/carton
Working Voltage DC16-30V Alarm Type Audible and Visual
Apaitplicon Conventional Smoke Alarm System Installation Wall-mounted
Sound Level ≥80dB Humidity Range 10% to 95% non-condensing
Operating Temperature -10°C to 50°C Detection Method Smoke and Heat
Customized Optional Brand Name XHA
Model Number XHA8061 Certification CE
Place of Origin China
High Light OEM Conventional Fire Alarm SystemODM Conventional Fire Alarm System80dB Audible And Visual Alarm

80dB Minimum Alarm Sound Audible-Visual Device For Conventional Fire Alarm System

 



Introduction

 

A sounder-flasher, also known as a combination sounder-strobe or audible-visual device is a type of fire alarm notification appliance that combines both audible and visual signaling capabilities. Here's a more detailed introduction to sounder-flashers:

 

Audible Signaling:
The sounder component of the device is responsible for producing an audible alarm, typically in the form of a siren, horn, or other loud sound.
The audible signal is designed to alert building occupants of the emergency and prompt them to evacuate the premises.
The volume and tone of the sounder are often adjustable to ensure the alarm can be heard clearly, even in noisy environments.


Visual Signaling:
The flasher or strobe component of the device is responsible for providing a visual alarm signal.
The strobe light, which typically flashes at a rate of 1-3 Hz, is intended to attract the attention of building occupants, particularly those who may have difficulty hearing the audible alarm.
The visual signal can be especially important for individuals who are hard of hearing or deaf, as it provides a supplementary means of alerting them to the emergency.


Integrated Design:
Sounder-flashers combine the audible and visual alarm capabilities into a single, integrated device.
This design helps to streamline the installation process and ensures that both audible and visual signals are consistently placed throughout the building.


Placement and Coverage:
Sounder-flashers are strategically placed throughout a building, often near exits, stairwells, and other common areas, to ensure adequate coverage and visibility.
The placement and quantity of sounder-flashers are typically determined by local fire codes and regulations to meet the specific needs of the building and its occupants.
Power Supply:
Sounder-flashers are typically connected to the building's fire alarm system, which provides the necessary power and control for their operation.

 

Features


The Sound Strobe of notification appliances offers a wide range of Sound/strobes, for wall and ceiling applications, indoors. They are designed to be used in 24 volt DC systems.
Key Specifications/Special Features
DC16-30V Powered
Long life of Strobe:Minimum 40000 times
Strobe flash rate: 1 flash per second
Loud alarm sound: Minimum 80dB
Suitable for the majority of conventional fire alarm systems

 

 

 

 


Product range

Conventional Fire Alarm System
Addressable fire alarm system
Gas Extinguishing control system
Beam Detector
4 wire smoke detectors with relay output.
2 wire Conventional smoke and heat detectors
Explosion-proof flame detector for fire alarm system
Standalone smoke detectors and combustable gas detector

 

 



Service

1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.

5. Welcome sample order.




 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Year Established:

    2001

  • Total Annual:

    4300000-7140000

  • Employee Number:

    40~50

  • Ecer Certification:

    Verified Supplier

We sepecializes in design and manufacture of high quality fire protection solutions for commerical, industrial and domestic applications. we have nearly 20 years experience in the field of fire protection industry.Everlasting desire for innovation drives our company's product development progres... We sepecializes in design and manufacture of high quality fire protection solutions for commerical, industrial and domestic applications. we have nearly 20 years experience in the field of fire protection industry.Everlasting desire for innovation drives our company's product development progres...

+ Read More

Get in touch with us

  • Reach Us
  • Shenzhen Xinhe'an Technology Co., Ltd.
  • 406,Jude Building,Zhengfeng South Road,Fuyong Street,Bao'An District, Shenzhen City, Guangdong Province. China,518103
  • https://www.xhafiresafety.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement