Payment Terms | T/T, L/C, D/A, D/P, Western Union |
Supply Ability | 2000 sets per month |
Delivery Time | 10-15 days |
Packaging Details | carton / wooden case |
Accuracy | 0.2%, 0.5% |
Product name | Electromagnetic heat meter, energy measurement |
Liquid media | conductive liquid, water |
Output | 4-20 mA, Pulse, frequency |
Communication | Modbus RS485, bacnet, Mbus, GPRS |
Medium temperature | -20℃~+120℃, -20°C - +180 °C, ≤120℃, -40~180℃ |
Work pressure | 16 bar / 1.6 Mpa / 232 psi / PN16 |
Usage | heating system, HVAC, sewage, waste water, STP, ETP |
Flow rate | 0.01 - 15 m/s, resolution: 0.0001 m/s |
Liner | PTFE, Rubber, NR |
Brand Name | Runpaq |
Model Number | YR-E80-2 |
Certification | CE, EXD |
Place of Origin | China |
View Detail Information
Explore similar products
Flange Thermal Mass Electromagnetic Water Flow Meter PN16 15m/S
Electromagnetic 316L Electrode Thermal Mass Flow Meter RS485 Communication
Seawater Electromagnetic Water Flow Meter With Rubber Liner
316L Electrode PTFE Liner Wastewater Flow Meter With Flanges Port
Product Specification
Payment Terms | T/T, L/C, D/A, D/P, Western Union | Supply Ability | 2000 sets per month |
Delivery Time | 10-15 days | Packaging Details | carton / wooden case |
Accuracy | 0.2%, 0.5% | Product name | Electromagnetic heat meter, energy measurement |
Liquid media | conductive liquid, water | Output | 4-20 mA, Pulse, frequency |
Communication | Modbus RS485, bacnet, Mbus, GPRS | Medium temperature | -20℃~+120℃, -20°C - +180 °C, ≤120℃, -40~180℃ |
Work pressure | 16 bar / 1.6 Mpa / 232 psi / PN16 | Usage | heating system, HVAC, sewage, waste water, STP, ETP |
Flow rate | 0.01 - 15 m/s, resolution: 0.0001 m/s | Liner | PTFE, Rubber, NR |
Brand Name | Runpaq | Model Number | YR-E80-2 |
Certification | CE, EXD | Place of Origin | China |
High Light | PTFE Electromagnetic Water Flow Meter ,PN16 Electromagnetic Water Flow Meter ,NR Thermal Mass Flow Meter |
flange Electromagnetic Water Flow Meter, Thermal Mass Flow Meter working principle
Description
Newly designed magnetic heat meter works on Law of Faraday's electromagnetic induction. We've owned our own patents: ZL2010 20145263.9 and ZL2011301682. It consists of: flow measurement, heat integrating unit and temperature sensor. The magnetic meter is designed to improve the accuracy and reliability of trade settlement in HVAC, centra air conditioning system.
The electromagnetic heat meter utilizes the relationship between flow rate and cooling effect for direct measurement of mass flow. With no moving parts and minimal invasiveness, thermal flow meters provide a highly repeatable, accurate, low cost, easy to install solution for flow measurements and calculating energy consumption. We provide flow meters suitable for applications in pipes and ducts, from DN10 to DN2000.
Measure theory
The electromagnetic flowmeters, can detect flow by using Faraday's Law of induction. Inside a magnetic flow meter, there is an electromagnetic coil, that generates a magnetic field, and the electrodes that capture electromotive force (voltage).
Features
Applications
MUNICIPAL WATER
INDUSTRIAL LIQUID
WASTEWATER
IRRIGATION
CHEMICALS
POWER SUPPLY
PHARMACEUTICALS
FOOD
PAPER PLANTS
METALLURGICAL MINES
Technical data
Product name | Electromagnetic flowmeter | ||
Product type | Local|compact display | Remote display | Signal converter |
Model | IYF-E | IYF-F | IRT |
Pipe Diameter (mm) | DN10-DN2000 | ||
Power supply | 100-240 VAC / 18-36 VDC | ||
Accuracy | + 0.5% | + 0.5% | + 0.5% |
Power consumption | <6w | <6w | <6w |
Enclosure rating | IP65 | IP68 | IP65 |
Liquid temperature | -25-120℃ | -25-120℃ | -25-120℃ |
Ambient temperature | -25-50℃ | -25-50℃ | -25-50℃ |
Relative humidity | 10-90% | 10-90% | 10-90% |
Meter ratio | 1:100 | 1:100 | 1:100 |
Flow direction | Bi-direction flow | Bi-direction flow | Bi-direction flow |
Communication | RS485 / Bacnet | RS485 / Bacnet | RS485 / Bacnet |
Signal Output | 4-20mA/Pulse/Frequency | 4-20mA/Pulse/Frequency | 4-20mA/Pulse/Frequency |
Accuracy
Pipe Dia (mm) | Velocity (m/s) | Accuracy |
3-20 | <0.3 | + 0.25% FS |
0.3-1 | + 1.0% Readout | |
1-15 | + 0.25% Readout | |
25-600 | 0.1-0.3 | + 0.25% FS |
0.3-1 | + 0.5% Readout | |
1-15 | + 0.3% Readout | |
700-3000 | <0.3 | + 0.25% FS |
0.3-1 | + 1.0% Readout | |
1-15 | + 0.25% Readout |
Model selection
Notice on the selection of local type and remote type:
Remote type means the transmitter and converter display are mounted in different locations, it’s suggested to select
remote type in the following conditions:
No | Model | ||||||||
YF | Electromagnetic flowmeter | ||||||||
TF | Turbine | ||||||||
VF | Votex | ||||||||
LX | Vane wheel | ||||||||
T | Ultrasonic | ||||||||
E/F display mode | E: compact/local display, F: remote display | ||||||||
Pipe Dia | Type (mm) | ||||||||
xxxx | 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 400, 500, 600, 800, 1000 | ||||||||
Code | Accuracy | ||||||||
1 | + 0.5% FS | ||||||||
2 | + 1.0% FS | ||||||||
3 | + 0.2% FS | ||||||||
Code | Type | ||||||||
N | Converter: 12 / 24 VDC, pulse output | ||||||||
A | Transmitter: 24VDC, 4-20mA outpt | ||||||||
B | Intelligent, Lion battery, no local display | ||||||||
G | Smart, local display, 4-20mA output | ||||||||
C1 | Smart, local display, RS485 | ||||||||
C2 | Smart, local display, HART | ||||||||
Code | Type | ||||||||
S | Carbon steel housing | ||||||||
L | Stainless steel housing | ||||||||
G | High pressure housing | ||||||||
HL | 316L electrode | ||||||||
HTi | Titanium electrode | ||||||||
HTa | Tantlum electrode | ||||||||
HC | Hastelloy-C electrode | ||||||||
L1 | Liquid media | ||||||||
L2 | Gas media | ||||||||
P | Pressure compensation | ||||||||
T | Temperature compensation | ||||||||
PT | Pressure&Temp. Compensation | ||||||||
F | PTFE liner | ||||||||
X | Rubber liner | ||||||||
Sample: IYF-E-0100-1-C1-S-HL-L1-F, Magmeter, local display, Dia: 100mm, + 0.5%FS, carbon steel housing, smart, 4-20mA outpt, RS485, 316L electrodes, liquid media meter, PTFE liner |
Applicable metering liquid:
Non-applicable metering medial
Pipe Diameter, flow volume and product dimension
Dia | Flow volume (m3/h) | Product dimension (mm) | |||||
(mm) | Normal | Min | Max | L | D | H | H1 |
15 | 1.5 | 0.06 | 9.5 | 150 | 95 | 272 | 254 |
20 | 2.5 | 0.11 | 16.9 | 105 | 277 | 254 | |
25 | 3.5 | 0.18 | 26.5 | 115 | 283 | 254 | |
32 | 6 | 0.29 | 43.6 | 140 | 297 | 270 | |
40 | 10 | 0.45 | 67.8 | 150 | 307 | 280 | |
50 | 15 | 0.71 | 106.0 | 200 | 165 | 318 | 294 |
65 | 25 | 1.19 | 179.1 | 185 | 337 | 313 | |
80 | 40 | 1.81 | 271.4 | 200 | 352 | 326 | |
100 | 60 | 2.83 | 424.1 | 250 | 220 | 371 | 344 |
125 | 100 | 4.42 | 665 | 250 | 401 | 372 | |
150 | 135 | 6.36 | 954 | 300 | 285 | 431 | 403 |
200 | 250 | 11.3 | 1696 | 350 | 340 | 486 | 460 |
250 | 375 | 17.66 | 2650 | 400 | 395 | 547 | 511 |
300 | 540 | 25.43 | 3817 | 450 | 445 | 597 | 565 |
350 | 735 | 34.62 | 5195 | 505 | 657 | 620 | |
400 | 960 | 45.22 | 6785 | 500 | 565 | 717 | 675 |
450 | 1200 | 57.23 | 8588 | 550 | 615 | 757 | 727 |
500 | 1500 | 70 | 10602 | 600 | 670 | 817 | 782 |
600 | 2160 | 100 | 15268 | 780 | 917 | 782 | |
700 | 2950 | 138 | 20781 | 700 | 895 | 1027 | 1068 |
800 | 3850 | 180 | 27100 | 800 | 1015 | 1137 | 1157 |
Industrial applications
Chemical | Food & beverage | Paper mill |
Metallurgy | Environment protection | Hydraulic |
Mining | Stainless | Petroleum |
Pharmacy | Air conditioner | Effluent treatment plant |
Seawater desalination | Pharmacy | Water treatment |
Competitive advantage
Details demonstration
Inhouse PCB production Silicon steel transformer Calibration line
How to use the magnetic flow meter
The ElectroMagnetic flowmeters measure the velocity of conductive liquids in pipes, such as water, acids, caustic, and slurries. Magnetic flowmeters can measure properly when the electrical conductivity of the liquid is greater than approximately 5μS/cm. Be careful because using magnetic flowmeters on fluids with low conductivity, such as deionized water, boiler feed water, or hydrocarbons, can cause the flowmeter to turn off and measure zero flow.
Company Details
Business Type:
Manufacturer,Agent
Year Established:
2009
Total Annual:
30000000-50000000
Employee Number:
100~200
Ecer Certification:
Active Member
We're a national key high-tech enterprise serving in fields of new energy management system and equipment, main services include: HVAC central air-conditioning and cold storage, solar distributed energy & regional energy, flow & energy management. We have integrative certification of ... We're a national key high-tech enterprise serving in fields of new energy management system and equipment, main services include: HVAC central air-conditioning and cold storage, solar distributed energy & regional energy, flow & energy management. We have integrative certification of ...
Get in touch with us
Leave a Message, we will call you back quickly!