Products
Manufacturer of a wide range of products which include 90KV Very Low Frequency VLF High Voltage Testing Set For Cable And Generator,90KV Very Low Frequency VLF High Voltage Testing Set For Cable And Generator,Variable Frequency AC...
MOQ: One Set
Price: Negotiable
Payment Terms | L/C, T/T |
Supply Ability | 20 sets / month |
Delivery Time | 20~30 working days |
Packaging Details | Export standard wooden case with fumigation free |
Test Principle: | Very-low frequency technology principle |
Usage | 0.1Hz Withstand Voltage test for 45KV and below MV power cable and generator |
Design Feature | Two HV boosters, 40KV/50KV for single one |
Component | Controller,HV booster,Compensation capacitor Load |
Test Frequency | 0.1Hz, 0.05Hz, 0.02Hz |
Max.Test Voltage | 0~ 90KV(peak), continuously adjustable |
Load Range: | 0.1Hz, ≤0.5μF ; 0.05HZ,≤0.1μF ;0.02HZ ≤2.5μF |
Test Accuracy | No Less Than 3% |
Output Waveform | Good Sine Wave,Voltage, Waveform distortion ≤ 5% |
HV Booster Using Way | Single or In Series Connection |
Duty Cycle | 60mints |
Brand Name | Fanke High-voltage |
Model Number | VLF-90KV/0.1Hz |
Certification | ISO9001 |
Place of Origin | China |
MOQ: One Set
Price: Negotiable
Payment Terms | L/C, T/T |
Supply Ability | 20 sets / month |
Delivery Time | 20~30 working days |
Packaging Details | Export standard wooden case with fumigation free |
Test Principle: | Very-low frequency technology principle |
Usage | 0.1Hz Withstand Voltage test for 45KV and below MV power cable and generator |
Design Feature | Two HV boosters, 40KV/50KV for single one |
Component | Controller,HV booster,Compensation capacitor Load |
Test Frequency | 0.1Hz, 0.05Hz, 0.02Hz |
Max.Test Voltage | 0~ 90KV(peak), continuously adjustable |
Load Range: | 0.1Hz, ≤0.5μF ; 0.05HZ,≤0.1μF ;0.02HZ ≤2.5μF |
Test Accuracy | No Less Than 3% |
Output Waveform | Good Sine Wave,Voltage, Waveform distortion ≤ 5% |
HV Booster Using Way | Single or In Series Connection |
Duty Cycle | 60mints |
Brand Name | Fanke High-voltage |
Model Number | VLF-90KV/0.1Hz |
Certification | ISO9001 |
Place of Origin | China |
MOQ: One Set
Price: Negotiable
Payment Terms | L/C, T/T |
Supply Ability | 5 sets / 2months |
Delivery Time | 45~60 working days |
Packaging Details | Export standard wooden case with fumigation free |
Test Principle | Variable Frequency Resonant Circuit |
Usage | On-site AC Withstand Voltage Test |
Design Feature: | Highed Voltage Modular Test Reactor, Higher Q Value Output ,Multiple Test Range |
Component: | V/F Power Source, Excitation Transformer,lighter Modular Test Reactor, And Voltage Divider |
Test Frequency: | 30-300Hz |
Duty Cycle | 15mints or 60 Mints |
Test Accuracy | No Less Than 1.5% |
Output Waveform | Good Sine Wave |
Special For | On-site Test For UHV GIS , GIL , CT, PT |
Test Standard: | IEC60060-1:2010;IEC 62271-203:2011 for GIS |
Brand Name | Fanke |
Model Number | CHX-4800KVA/200KV,400KV,600KV,800KV |
Certification | ISO9001 |
Place of Origin | CHINA |
MOQ: One Set
Price: Negotiable
Payment Terms | L/C, T/T |
Supply Ability | 5 sets / 2months |
Delivery Time | 45~60 working days |
Packaging Details | Export standard wooden case with fumigation free |
Test Principle | Variable Frequency Resonant Circuit |
Usage | On-site AC Withstand Voltage Test |
Design Feature: | Highed Voltage Modular Test Reactor, Higher Q Value Output ,Multiple Test Range |
Component: | V/F Power Source, Excitation Transformer,lighter Modular Test Reactor, And Voltage Divider |
Test Frequency: | 30-300Hz |
Duty Cycle | 15mints or 60 Mints |
Test Accuracy | No Less Than 1.5% |
Output Waveform | Good Sine Wave |
Special For | On-site Test For UHV GIS , GIL , CT, PT |
Test Standard: | IEC60060-1:2010;IEC 62271-203:2011 for GIS |
Brand Name | Fanke |
Model Number | CHX-4800KVA/200KV,400KV,600KV,800KV |
Certification | ISO9001 |
Place of Origin | CHINA |
MOQ: One unit
Price: Negotiable
Payment Terms | T/T |
Supply Ability | 4units/2months |
Delivery Time | 45-65 work days |
Packaging Details | Export Standard Wooden Case With Fumigation Free |
Usage | Measurement and control unit for Power Frequency AC resonant withstand voltage test circuit. |
Advantage | best protections and best monitoring functions |
Operation way | Double control way , PLC computer control or manual button control |
Speical for | Replace the old traditional console to increase the efficiency |
Max.Control voltage | no limit, made by order |
Max.Control current | no limit, made by order |
Test Accuracy | No Less Than 1.5% |
Power supply | 380V, 50/60Hz, Single phase |
Brand Name | Fanke High-voltage |
Model Number | CHX-(L) Series |
Certification | ISO9001 |
Place of Origin | CHINA |
MOQ: One unit
Price: Negotiable
Payment Terms | T/T |
Supply Ability | 4units/2months |
Delivery Time | 45-65 work days |
Packaging Details | Export Standard Wooden Case With Fumigation Free |
Usage | Measurement and control unit for Power Frequency AC resonant withstand voltage test circuit. |
Advantage | best protections and best monitoring functions |
Operation way | Double control way , PLC computer control or manual button control |
Speical for | Replace the old traditional console to increase the efficiency |
Max.Control voltage | no limit, made by order |
Max.Control current | no limit, made by order |
Test Accuracy | No Less Than 1.5% |
Power supply | 380V, 50/60Hz, Single phase |
Brand Name | Fanke High-voltage |
Model Number | CHX-(L) Series |
Certification | ISO9001 |
Place of Origin | CHINA |
MOQ: One unit
Price: Negotiable
Payment Terms | L/C, T/T |
Supply Ability | 2units/3months |
Delivery Time | 65~90 work days |
Packaging Details | Export Standard Wooden Case With Fumigation Free |
Usage | EHV CVT and CB Rutine Testing |
Test Item | AC Hipot Test And Partial Discharge Test |
Test Voltage | No More Than 800KV |
Test Current | No More Than 5A |
Test Frequency | 50Hz or 60Hz |
PD Free | No More Than 10pC At 800KV |
Duty Cycle | 30mints or made by order |
Test Accuracy | No Less Than 1.0% |
Brand Name | Fanke High-voltage |
Model Number | CHX-(L) Series |
Certification | ISO9001 |
Place of Origin | CHINA |
MOQ: One unit
Price: Negotiable
Payment Terms | L/C, T/T |
Supply Ability | 2units/3months |
Delivery Time | 65~90 work days |
Packaging Details | Export Standard Wooden Case With Fumigation Free |
Usage | EHV CVT and CB Rutine Testing |
Test Item | AC Hipot Test And Partial Discharge Test |
Test Voltage | No More Than 800KV |
Test Current | No More Than 5A |
Test Frequency | 50Hz or 60Hz |
PD Free | No More Than 10pC At 800KV |
Duty Cycle | 30mints or made by order |
Test Accuracy | No Less Than 1.0% |
Brand Name | Fanke High-voltage |
Model Number | CHX-(L) Series |
Certification | ISO9001 |
Place of Origin | CHINA |
MOQ: One Set
Price: Negotiable
Payment Terms | L/C, T/T |
Supply Ability | 5 sets / 2months |
Delivery Time | 45~60 working days |
Packaging Details | Export standard wooden case with fumigation free |
Test Principle | Variable Frequency Resonant Circuit |
Usage | On-site AC Withstand Voltage Test Under 200KV,400KV,600KV, 800KV For HV GIS or GIL |
Design Feature: | Highed Voltage Modular Test Reactor, Higher Q Value Output ,Multiple Test Range |
Component: | V/F Power Source, Excitation Transformer,lighter Modular Test Reactor, And Voltage Divider |
Test Frequency: | 30-300Hz |
Duty Cycle | 15mints or 60 Mints |
Test Accuracy | No Less Than 1.5% |
Output Waveform | Good Sine Wave |
Special For | On-site Test For HV or EHV GIS ,CT,PT |
Reactor Using Way | In Series Or In Parallel Connection |
Test Standard: | IEC60060-1:2010;IEC 62271-203:2011 for GIS |
Brand Name | Fanke |
Model Number | CHX-4800KVA/200KV,400KV,600KV,800KV |
Certification | ISO9001 |
Place of Origin | CHINA |
MOQ: One Set
Price: Negotiable
Payment Terms | L/C, T/T |
Supply Ability | 5 sets / 2months |
Delivery Time | 45~60 working days |
Packaging Details | Export standard wooden case with fumigation free |
Test Principle | Variable Frequency Resonant Circuit |
Usage | On-site AC Withstand Voltage Test Under 200KV,400KV,600KV, 800KV For HV GIS or GIL |
Design Feature: | Highed Voltage Modular Test Reactor, Higher Q Value Output ,Multiple Test Range |
Component: | V/F Power Source, Excitation Transformer,lighter Modular Test Reactor, And Voltage Divider |
Test Frequency: | 30-300Hz |
Duty Cycle | 15mints or 60 Mints |
Test Accuracy | No Less Than 1.5% |
Output Waveform | Good Sine Wave |
Special For | On-site Test For HV or EHV GIS ,CT,PT |
Reactor Using Way | In Series Or In Parallel Connection |
Test Standard: | IEC60060-1:2010;IEC 62271-203:2011 for GIS |
Brand Name | Fanke |
Model Number | CHX-4800KVA/200KV,400KV,600KV,800KV |
Certification | ISO9001 |
Place of Origin | CHINA |