Products
Manufacturer of a wide range of products which include 90KV Very Low Frequency VLF High Voltage Testing Set For Cable And Generator,90KV Very Low Frequency VLF High Voltage Testing Set For Cable And Generator,Variable Frequency Re...
MOQ: One Set
Price: Negotiable
Payment Terms | L/C, T/T |
Supply Ability | 20 sets / month |
Delivery Time | 20~30 working days |
Packaging Details | Export standard wooden case with fumigation free |
Test Principle: | Very-low frequency technology principle |
Usage | 0.1Hz Withstand Voltage test for 45KV and below MV power cable and generator |
Design Feature | Two HV boosters, 40KV/50KV for single one |
Component | Controller,HV booster,Compensation capacitor Load |
Test Frequency | 0.1Hz, 0.05Hz, 0.02Hz |
Max.Test Voltage | 0~ 90KV(peak), continuously adjustable |
Load Range: | 0.1Hz, ≤0.5μF ; 0.05HZ,≤0.1μF ;0.02HZ ≤2.5μF |
Test Accuracy | No Less Than 3% |
Output Waveform | Good Sine Wave,Voltage, Waveform distortion ≤ 5% |
HV Booster Using Way | Single or In Series Connection |
Duty Cycle | 60mints |
Brand Name | Fanke High-voltage |
Model Number | VLF-90KV/0.1Hz |
Certification | ISO9001 |
Place of Origin | China |
MOQ: One Set
Price: Negotiable
Payment Terms | L/C, T/T |
Supply Ability | 20 sets / month |
Delivery Time | 20~30 working days |
Packaging Details | Export standard wooden case with fumigation free |
Test Principle: | Very-low frequency technology principle |
Usage | 0.1Hz Withstand Voltage test for 45KV and below MV power cable and generator |
Design Feature | Two HV boosters, 40KV/50KV for single one |
Component | Controller,HV booster,Compensation capacitor Load |
Test Frequency | 0.1Hz, 0.05Hz, 0.02Hz |
Max.Test Voltage | 0~ 90KV(peak), continuously adjustable |
Load Range: | 0.1Hz, ≤0.5μF ; 0.05HZ,≤0.1μF ;0.02HZ ≤2.5μF |
Test Accuracy | No Less Than 3% |
Output Waveform | Good Sine Wave,Voltage, Waveform distortion ≤ 5% |
HV Booster Using Way | Single or In Series Connection |
Duty Cycle | 60mints |
Brand Name | Fanke High-voltage |
Model Number | VLF-90KV/0.1Hz |
Certification | ISO9001 |
Place of Origin | China |
MOQ: One Unit
Price: Negotiable
Payment Terms | L/C, T/T |
Supply Ability | 10sets / 3months |
Delivery Time | 75~90 Working Days |
Packaging Details | Export Standard Wooden Case With Fumigation Free |
Test Principle | Variable Frequency Resonant Circuit |
Usage | AC Withstand Voltage Test |
MAX.Capacity | 9000KVA |
Max.Voltage | 150KV,300KV,450KV |
Test Frequency | 20-300Hz |
Duty Cycle | 60 mints |
Test Accuracy | No less than 1.5% |
Special For | On-site Test For long HV XLPE cable and GIS |
Test Standard | IEC 60060-1:2010;IEC 60840:2011 and IEC 62067:2011 for XLPE cable |
Brand Name | Fanke High-voltage |
Model Number | CHX-9000KVA/150KV,300KV,450KV |
Certification | ISO9001 |
Place of Origin | Wuhan ,China |
MOQ: One Unit
Price: Negotiable
Payment Terms | L/C, T/T |
Supply Ability | 10sets / 3months |
Delivery Time | 75~90 Working Days |
Packaging Details | Export Standard Wooden Case With Fumigation Free |
Test Principle | Variable Frequency Resonant Circuit |
Usage | AC Withstand Voltage Test |
MAX.Capacity | 9000KVA |
Max.Voltage | 150KV,300KV,450KV |
Test Frequency | 20-300Hz |
Duty Cycle | 60 mints |
Test Accuracy | No less than 1.5% |
Special For | On-site Test For long HV XLPE cable and GIS |
Test Standard | IEC 60060-1:2010;IEC 60840:2011 and IEC 62067:2011 for XLPE cable |
Brand Name | Fanke High-voltage |
Model Number | CHX-9000KVA/150KV,300KV,450KV |
Certification | ISO9001 |
Place of Origin | Wuhan ,China |
MOQ: One Unit
Price: Negotiable
Payment Terms | L/C, T/T |
Supply Ability | 5sets /month |
Delivery Time | 25~30 Working Days |
Packaging Details | Export Standard Wooden Case With Fumigation Free |
Test Principle | Variable Frequency or variable inductance resonant Circuit |
Usage | HV booster in resonant test system |
MAX.Capacity | 25A/piece or OEM |
Max.Voltage | 400KV/piece or OEM |
Test Frequency | 20-300Hz or 50Hz |
Duty Cycle | 60 mints or OEM |
Test Accuracy | No less than 1.5% |
Special For | On-site Test For long HV XLPE cable and GIS |
Test Standard | IEC 60060-1:2010;IEC 60840:2011 and IEC 62067:2011 for XLPE cable |
Brand Name | Fanke High-voltage |
Model Number | CHX series or OEM |
Certification | ISO9001 |
Place of Origin | Wuhan ,China |
MOQ: One Unit
Price: Negotiable
Payment Terms | L/C, T/T |
Supply Ability | 5sets /month |
Delivery Time | 25~30 Working Days |
Packaging Details | Export Standard Wooden Case With Fumigation Free |
Test Principle | Variable Frequency or variable inductance resonant Circuit |
Usage | HV booster in resonant test system |
MAX.Capacity | 25A/piece or OEM |
Max.Voltage | 400KV/piece or OEM |
Test Frequency | 20-300Hz or 50Hz |
Duty Cycle | 60 mints or OEM |
Test Accuracy | No less than 1.5% |
Special For | On-site Test For long HV XLPE cable and GIS |
Test Standard | IEC 60060-1:2010;IEC 60840:2011 and IEC 62067:2011 for XLPE cable |
Brand Name | Fanke High-voltage |
Model Number | CHX series or OEM |
Certification | ISO9001 |
Place of Origin | Wuhan ,China |
MOQ: One Unit
Price: Negotiable
Payment Terms | L/C, T/T |
Supply Ability | 5sets /month |
Delivery Time | 25~30 Working Days |
Packaging Details | Export Standard Wooden Case With Fumigation Free |
Test Principle | Variable Frequency Resonant Circuit |
Usage | HV booster in AC Withstand Voltage Test |
MAX.Capacity | 25A/piece or OEM |
Max.Voltage | 400KV/piece or OEM |
Test Frequency | 20-300Hz |
Duty Cycle | 60 mints or OEM |
Test Accuracy | No less than 1.5% |
Special For | On-site Test For long HV XLPE cable and GIS |
Test Standard | IEC 60060-1:2010;IEC 60840:2011 and IEC 62067:2011 for XLPE cable |
Brand Name | Fanke High-voltage |
Model Number | CHX series |
Certification | ISO9001 |
Place of Origin | Wuhan ,China |
MOQ: One Unit
Price: Negotiable
Payment Terms | L/C, T/T |
Supply Ability | 5sets /month |
Delivery Time | 25~30 Working Days |
Packaging Details | Export Standard Wooden Case With Fumigation Free |
Test Principle | Variable Frequency Resonant Circuit |
Usage | HV booster in AC Withstand Voltage Test |
MAX.Capacity | 25A/piece or OEM |
Max.Voltage | 400KV/piece or OEM |
Test Frequency | 20-300Hz |
Duty Cycle | 60 mints or OEM |
Test Accuracy | No less than 1.5% |
Special For | On-site Test For long HV XLPE cable and GIS |
Test Standard | IEC 60060-1:2010;IEC 60840:2011 and IEC 62067:2011 for XLPE cable |
Brand Name | Fanke High-voltage |
Model Number | CHX series |
Certification | ISO9001 |
Place of Origin | Wuhan ,China |
MOQ: One Unit
Price: Negotiable
Payment Terms | L/C, T/T |
Supply Ability | 10sets / 3months |
Delivery Time | 75~90 Working Days |
Packaging Details | Export Standard Wooden Case With Fumigation Free |
Principle | Typical LC Test Circuit |
Appilcation | AC Withstand Voltage Test At Site |
MAX.Capacity | OEM |
Max.Voltage | OEM |
Design Feature | Cylinder And Modular Type Test Reactor |
Test Frequency | 20-300Hz |
Duty Cycle | 60 mints or OEM |
Output waveform | Good Sine Wave |
Ordered way | Components may be ordered separately |
Brand Name | Fanke High-voltage |
Model Number | CHX Series |
Certification | ISO9001 |
Place of Origin | Wuhan ,China |
MOQ: One Unit
Price: Negotiable
Payment Terms | L/C, T/T |
Supply Ability | 10sets / 3months |
Delivery Time | 75~90 Working Days |
Packaging Details | Export Standard Wooden Case With Fumigation Free |
Principle | Typical LC Test Circuit |
Appilcation | AC Withstand Voltage Test At Site |
MAX.Capacity | OEM |
Max.Voltage | OEM |
Design Feature | Cylinder And Modular Type Test Reactor |
Test Frequency | 20-300Hz |
Duty Cycle | 60 mints or OEM |
Output waveform | Good Sine Wave |
Ordered way | Components may be ordered separately |
Brand Name | Fanke High-voltage |
Model Number | CHX Series |
Certification | ISO9001 |
Place of Origin | Wuhan ,China |