Products
Manufacturer of a wide range of products which include 90KV Very Low Frequency VLF High Voltage Testing Set For Cable And Generator,90KV Very Low Frequency VLF High Voltage Testing Set For Cable And Generator,Large Power Generator...
MOQ: One Set
Price: Negotiable
Payment Terms | L/C, T/T |
Supply Ability | 20 sets / month |
Delivery Time | 20~30 working days |
Packaging Details | Export standard wooden case with fumigation free |
Test Principle: | Very-low frequency technology principle |
Usage | 0.1Hz Withstand Voltage test for 45KV and below MV power cable and generator |
Design Feature | Two HV boosters, 40KV/50KV for single one |
Component | Controller,HV booster,Compensation capacitor Load |
Test Frequency | 0.1Hz, 0.05Hz, 0.02Hz |
Max.Test Voltage | 0~ 90KV(peak), continuously adjustable |
Load Range: | 0.1Hz, ≤0.5μF ; 0.05HZ,≤0.1μF ;0.02HZ ≤2.5μF |
Test Accuracy | No Less Than 3% |
Output Waveform | Good Sine Wave,Voltage, Waveform distortion ≤ 5% |
HV Booster Using Way | Single or In Series Connection |
Duty Cycle | 60mints |
Brand Name | Fanke High-voltage |
Model Number | VLF-90KV/0.1Hz |
Certification | ISO9001 |
Place of Origin | China |
MOQ: One Set
Price: Negotiable
Payment Terms | L/C, T/T |
Supply Ability | 20 sets / month |
Delivery Time | 20~30 working days |
Packaging Details | Export standard wooden case with fumigation free |
Test Principle: | Very-low frequency technology principle |
Usage | 0.1Hz Withstand Voltage test for 45KV and below MV power cable and generator |
Design Feature | Two HV boosters, 40KV/50KV for single one |
Component | Controller,HV booster,Compensation capacitor Load |
Test Frequency | 0.1Hz, 0.05Hz, 0.02Hz |
Max.Test Voltage | 0~ 90KV(peak), continuously adjustable |
Load Range: | 0.1Hz, ≤0.5μF ; 0.05HZ,≤0.1μF ;0.02HZ ≤2.5μF |
Test Accuracy | No Less Than 3% |
Output Waveform | Good Sine Wave,Voltage, Waveform distortion ≤ 5% |
HV Booster Using Way | Single or In Series Connection |
Duty Cycle | 60mints |
Brand Name | Fanke High-voltage |
Model Number | VLF-90KV/0.1Hz |
Certification | ISO9001 |
Place of Origin | China |
MOQ: One unit
Price: 40000~150000 USD /Unit according to detailed model
Payment Terms | L/C, T/T |
Supply Ability | 5units/2months |
Delivery Time | 35~45 work days |
Packaging Details | Export standard wooden case with fumigation free |
Test Principle | Power Frequency Resonant Circuit |
Usage | AC Hipot Test for large generator stator or rotor winding |
Max.capacity: | 3750KVA |
Max. Voltage | 65KV |
Design Feature: | Adjustable inductance test reactor , 50Hz or 60Hz testing ,Dedicated to large hydroelectric generator stator test |
Component | Control console,Voltage regulator,Excitation Transformer,Adjustable inductance reactor, Optional load compensation load reactor, And Voltage Divider |
Test Frequency | 50Hz or 60Hz |
Duty Cycle | 10mints or made by order |
Test Accuracy | No Less Than 1.0% |
Output Waveform | Pure Sine Wave |
Special For | AC Hipot test for Large hydro-generator stator or thermal generator stator |
Test Standard: | IEC60060-1:2010 ; IEC 60034-1:2004; IEEE 115:2009; GB/T 8564-2003; JB/T 6204-2002 |
Note | PD free Type can be made by order |
Brand Name | Fanke High-voltage |
Model Number | CHX-L-3750KVA/65KV |
Certification | ISO9001 |
Place of Origin | CHINA |
MOQ: One unit
Price: 40000~150000 USD /Unit according to detailed model
Payment Terms | L/C, T/T |
Supply Ability | 5units/2months |
Delivery Time | 35~45 work days |
Packaging Details | Export standard wooden case with fumigation free |
Test Principle | Power Frequency Resonant Circuit |
Usage | AC Hipot Test for large generator stator or rotor winding |
Max.capacity: | 3750KVA |
Max. Voltage | 65KV |
Design Feature: | Adjustable inductance test reactor , 50Hz or 60Hz testing ,Dedicated to large hydroelectric generator stator test |
Component | Control console,Voltage regulator,Excitation Transformer,Adjustable inductance reactor, Optional load compensation load reactor, And Voltage Divider |
Test Frequency | 50Hz or 60Hz |
Duty Cycle | 10mints or made by order |
Test Accuracy | No Less Than 1.0% |
Output Waveform | Pure Sine Wave |
Special For | AC Hipot test for Large hydro-generator stator or thermal generator stator |
Test Standard: | IEC60060-1:2010 ; IEC 60034-1:2004; IEEE 115:2009; GB/T 8564-2003; JB/T 6204-2002 |
Note | PD free Type can be made by order |
Brand Name | Fanke High-voltage |
Model Number | CHX-L-3750KVA/65KV |
Certification | ISO9001 |
Place of Origin | CHINA |
MOQ: One unit
Price: Negotiable
Payment Terms | T/T |
Supply Ability | 5units/1months |
Delivery Time | 15~25 work days |
Packaging Details | Export standard wooden case with fumigation free |
Usage | DC hipot test for big power generator with water-cooled |
Appliaction | Generator test machine |
Max. voltage | 80KV |
Max. Output current | 200mA |
Max .Output power | 16KW |
Component | Control console,DC HV booster,Test connection wires |
Power supply | AC 380V±10% three phase four wires;50/60Hz |
Test Accuracy | 1.5%(full scale)±1 LSB |
Ripple factor | ≤3% |
Weight | Control console: 40kgs,DC HV booster: 40kgs |
Brand Name | Fanke High-voltage |
Model Number | FKSZG-80KV/200mA |
Certification | ISO9001 |
Place of Origin | Wuhan , China |
MOQ: One Unit
Price: Negotiable
Payment Terms | L/C, T/T |
Supply Ability | 5sets /month |
Delivery Time | 25~45 Working Days |
Packaging Details | Export Standard Wooden Case With Fumigation Free |
Test Principle | Variable inductance resonant Circuit |
Usage | HV booster in resonant test system |
MAX.Capacity | 45A/piece or OEM |
Max.Voltage | 60KV/piece or OEM |
Test Frequency | 50Hz/60Hz |
Duty Cycle | 15 mints or OEM |
Test Accuracy | No less than 1.5% |
Special For | AC hipot test for big capacity power generator |
Brand Name | Fanke High-voltage |
Model Number | CHX series or OEM |
Certification | ISO9001 |
Place of Origin | Wuhan ,China |
MOQ: One unit
Price: Negotiable
Payment Terms | T/T |
Supply Ability | 5units/1months |
Delivery Time | 15~25 work days |
Packaging Details | Export standard wooden case with fumigation free |
Usage | DC hipot test for big power generator with water-cooled |
Appliaction | Generator test machine |
Max. voltage | 80KV |
Max. Output current | 200mA |
Max .Output power | 16KW |
Component | Control console,DC HV booster,Test connection wires |
Power supply | AC 380V±10% three phase four wires;50/60Hz |
Test Accuracy | 1.5%(full scale)±1 LSB |
Ripple factor | ≤3% |
Weight | Control console: 40kgs,DC HV booster: 40kgs |
Brand Name | Fanke High-voltage |
Model Number | FKSZG-80KV/200mA |
Certification | ISO9001 |
Place of Origin | Wuhan , China |
MOQ: One Unit
Price: Negotiable
Payment Terms | L/C, T/T |
Supply Ability | 5sets /month |
Delivery Time | 25~45 Working Days |
Packaging Details | Export Standard Wooden Case With Fumigation Free |
Test Principle | Variable inductance resonant Circuit |
Usage | HV booster in resonant test system |
MAX.Capacity | 45A/piece or OEM |
Max.Voltage | 60KV/piece or OEM |
Test Frequency | 50Hz/60Hz |
Duty Cycle | 15 mints or OEM |
Test Accuracy | No less than 1.5% |
Special For | AC hipot test for big capacity power generator |
Brand Name | Fanke High-voltage |
Model Number | CHX series or OEM |
Certification | ISO9001 |
Place of Origin | Wuhan ,China |
MOQ: One unit
Price: Negotiable
Payment Terms | T/T |
Supply Ability | 5units/1months |
Delivery Time | 10~20 work days |
Packaging Details | Export standard wooden case with fumigation free |
Usage | Very Low Frequency Voltage Withstand Test |
Appliaction | Diagnosing Stator End Insulation Defects |
Max. voltage | 60KV (80KV can be ordered) |
Output frequency | 0.1Hz, 0.05Hz, 0.02Hz |
Test Accuracy | 3% |
Voltage wave form distortion | ≤ 5% |
Output waveform | Sine wave |
Power supply | AC50Hz, 220V ±5% |
Brand Name | Fanke High-voltage |
Model Number | VLF-60KV or VLF-80KV |
Certification | ISO9001 |
Place of Origin | Wuhan , China |
MOQ: One unit
Price: Negotiable
Payment Terms | T/T |
Supply Ability | 10units/month |
Delivery Time | 10 work days |
Packaging Details | Export standard wooden case with fumigation free |
Usage | Capacitance & Tan Delta Tester within 12KV or 12KV |
HV output | 0-12KV |
Test object | Motor , power generator and so on. |
Test range | 50pF~1uF; 0~12KV |
Anti-interference | Variable Frequency Method, 5mA |
Test Accuracy | Reading*1.5% |
Brand Name | Fanke High-Voltage |
Model Number | FKGST 12KV |
Certification | ISO9001 |
Place of Origin | China |