Products
Manufacturer of a wide range of products which include Large Power Generator Test Equipment Power Frequency Resonant Circuit Test,Large Power Generator Test Equipment Power Frequency Resonant Circuit Test,400KVA Circuit Breaker Te...
MOQ: One unit
Price: 40000~150000 USD /Unit according to detailed model
Payment Terms | L/C, T/T |
Supply Ability | 5units/2months |
Delivery Time | 35~45 work days |
Packaging Details | Export standard wooden case with fumigation free |
Test Principle | Power Frequency Resonant Circuit |
Usage | AC Hipot Test for large generator stator or rotor winding |
Max.capacity: | 3750KVA |
Max. Voltage | 65KV |
Design Feature: | Adjustable inductance test reactor , 50Hz or 60Hz testing ,Dedicated to large hydroelectric generator stator test |
Component | Control console,Voltage regulator,Excitation Transformer,Adjustable inductance reactor, Optional load compensation load reactor, And Voltage Divider |
Test Frequency | 50Hz or 60Hz |
Duty Cycle | 10mints or made by order |
Test Accuracy | No Less Than 1.0% |
Output Waveform | Pure Sine Wave |
Special For | AC Hipot test for Large hydro-generator stator or thermal generator stator |
Test Standard: | IEC60060-1:2010 ; IEC 60034-1:2004; IEEE 115:2009; GB/T 8564-2003; JB/T 6204-2002 |
Note | PD free Type can be made by order |
Brand Name | Fanke High-voltage |
Model Number | CHX-L-3750KVA/65KV |
Certification | ISO9001 |
Place of Origin | CHINA |
MOQ: One unit
Price: 40000~150000 USD /Unit according to detailed model
Payment Terms | L/C, T/T |
Supply Ability | 5units/2months |
Delivery Time | 35~45 work days |
Packaging Details | Export standard wooden case with fumigation free |
Test Principle | Power Frequency Resonant Circuit |
Usage | AC Hipot Test for large generator stator or rotor winding |
Max.capacity: | 3750KVA |
Max. Voltage | 65KV |
Design Feature: | Adjustable inductance test reactor , 50Hz or 60Hz testing ,Dedicated to large hydroelectric generator stator test |
Component | Control console,Voltage regulator,Excitation Transformer,Adjustable inductance reactor, Optional load compensation load reactor, And Voltage Divider |
Test Frequency | 50Hz or 60Hz |
Duty Cycle | 10mints or made by order |
Test Accuracy | No Less Than 1.0% |
Output Waveform | Pure Sine Wave |
Special For | AC Hipot test for Large hydro-generator stator or thermal generator stator |
Test Standard: | IEC60060-1:2010 ; IEC 60034-1:2004; IEEE 115:2009; GB/T 8564-2003; JB/T 6204-2002 |
Note | PD free Type can be made by order |
Brand Name | Fanke High-voltage |
Model Number | CHX-L-3750KVA/65KV |
Certification | ISO9001 |
Place of Origin | CHINA |
MOQ: One unit
Price: Negotiable
Payment Terms | L/C , T/T |
Supply Ability | 5units/2months |
Delivery Time | 45~75 work days |
Packaging Details | Export standard wooden case with fumigation free |
Test Principle | Power Frequency Test Transformer Circuit |
Application | AC hipot test and PD measurement for CB |
Max.capacity | 400KVA |
Max. Voltage | 400KV |
Usage | Factory quality inspection machine |
Component: | Control Console,Voltage Regulator,Cylinder Type Test Transformer, Protection resistance,And Voltage Divider |
Test Frequency | 50Hz Or 60Hz |
Duty Cycle | 60mints Or Made By Order |
Test Accuracy | No Less Than 1.0% |
Output Waveform | Pure Sine Wave |
PD level | PD free , No corona , No more than 5pC |
Brand Name | Fanke High-Voltage |
Model Number | CQSB-400KVA/400KV |
Certification | ISO9001 |
Place of Origin | China |
MOQ: One unit
Price: Negotiable
Payment Terms | L/C , T/T |
Supply Ability | 5units/2months |
Delivery Time | 45~75 work days |
Packaging Details | Export standard wooden case with fumigation free |
Test Principle | Power Frequency Test Transformer Circuit |
Application | AC hipot test and PD measurement for CB |
Max.capacity | 400KVA |
Max. Voltage | 400KV |
Usage | Factory quality inspection machine |
Component: | Control Console,Voltage Regulator,Cylinder Type Test Transformer, Protection resistance,And Voltage Divider |
Test Frequency | 50Hz Or 60Hz |
Duty Cycle | 60mints Or Made By Order |
Test Accuracy | No Less Than 1.0% |
Output Waveform | Pure Sine Wave |
PD level | PD free , No corona , No more than 5pC |
Brand Name | Fanke High-Voltage |
Model Number | CQSB-400KVA/400KV |
Certification | ISO9001 |
Place of Origin | China |
MOQ: One unit
Price: Negotiable
Payment Terms | T/T |
Supply Ability | 10units/month |
Delivery Time | 10 work days |
Packaging Details | Export standard wooden case with fumigation free |
Usage | Breaker Dynamic Characteristics Test |
Using field | Circuit Breaker Analyzer |
Time Test Channels | 6 or 12 channels optional |
Tested CB kinds | Vacuum, SF6, less oil, more oil type CB |
DC current source | 25~265V continuously adjustable,output current:≤ 15A( short time) |
Matched Sensor | linear displacement sensor 0-500mm/ 360 line sensor 0-1000mm |
Brand Name | Fanke High-Voltage |
Model Number | FKGC series |
Certification | ISO9001 |
Place of Origin | China |
MOQ: One unit
Price: Negotiable
Payment Terms | T/T |
Supply Ability | 10units/month |
Delivery Time | 10 work days |
Packaging Details | Export standard wooden case with fumigation free |
Usage | Breaker Dynamic Characteristics Test |
Using field | Circuit Breaker Analyzer |
Time Test Channels | 6 or 12 channels optional |
Tested CB kinds | Vacuum, SF6, less oil, more oil type CB |
DC current source | 25~265V continuously adjustable,output current:≤ 15A( short time) |
Matched Sensor | linear displacement sensor 0-500mm/ 360 line sensor 0-1000mm |
Brand Name | Fanke High-Voltage |
Model Number | FKGC series |
Certification | ISO9001 |
Place of Origin | China |
MOQ: One unit
Price: Negotiable
Payment Terms | T/T |
Supply Ability | 10units/month |
Delivery Time | 10 work days |
Packaging Details | Export standard wooden case with fumigation free |
Usage | Circuit Breaker Contact Resistance Test |
Test current | 50A, 100A, 200A three gears output |
Testing range | 0~100 mΩ |
Optional Function | With Micro-printer |
Test Accuracy | 0.5%±0.2µΩ |
Min. resolution | 0.01μΩ |
Brand Name | Fanke High-Voltage |
Model Number | KDC-200A |
Certification | ISO9001 |
Place of Origin | China |
MOQ: One unit
Price: Negotiable
Payment Terms | T/T |
Supply Ability | 10units/month |
Delivery Time | 10 work days |
Packaging Details | Export standard wooden case with fumigation free |
Usage | Circuit Breaker Contact Resistance Test |
Test current | 0-100A / 500VA output |
Testing range | 10~19999μΩ |
Optional Function | With Micro-printer |
Test Accuracy | +-(0.5%+2d) |
Min. resolution | 0.01μΩ |
Brand Name | Fanke High-Voltage |
Model Number | KDC-100A |
Certification | ISO9001 |
Place of Origin | China |
MOQ: One unit
Price: Negotiable
Payment Terms | T/T |
Supply Ability | 10units/month |
Delivery Time | 10 work days |
Packaging Details | Export standard wooden case with fumigation free |
Usage | Circuit Breaker Contact Resistance Test |
Test current | 50A, 100A, 200A three gears output |
Testing range | 0~100 mΩ |
Optional Function | With Micro-printer |
Test Accuracy | 0.5%±0.2µΩ |
Min. resolution | 0.01μΩ |
Brand Name | Fanke High-Voltage |
Model Number | KDC-200A |
Certification | ISO9001 |
Place of Origin | China |
MOQ: One unit
Price: Negotiable
Payment Terms | T/T |
Supply Ability | 10units/month |
Delivery Time | 10 work days |
Packaging Details | Export standard wooden case with fumigation free |
Usage | Circuit Breaker Contact Resistance Test |
Test current | 0-100A / 500VA output |
Testing range | 10~19999μΩ |
Optional Function | With Micro-printer |
Test Accuracy | +-(0.5%+2d) |
Min. resolution | 0.01μΩ |
Brand Name | Fanke High-Voltage |
Model Number | KDC-100A |
Certification | ISO9001 |
Place of Origin | China |